ELECTRICAL PANEL METER AND INSTRUMENTATIONS

JILAN ANAK GAWING


860309-52-6343
ILP MIRI
CH00870 L1-L3
EIC C01023
1
Electrical Quantity can be Measured and Commonly
Displayed at Panel.
 1.Current@Ampere
 2.Voltage
 3.Power
 4. Power Factor
 5.Frequency
 3.Speed
 4. Temperature

2
VOLTAGE MEASUREMENT

3
Voltmeter Types

4
Voltmeter Selector Switch

5
Connections of Voltmeter
(V/SW + Voltmeter)

• Sketch Schematic Connection Diagrams and Single line Drawing.

6
Connections of Voltmeter
(V/SW + Voltmeter+Indicator Lamp)

• Sketch Schematic Connection Diagrams and Single line Drawing.


7
Indicator Lamp for Panel
• indicating certain condition which required by system such as
phase indication, alarm, warning, position.

8
CURRENT(AMPERE) MEASUREMENT

9
Type for Ammeter

10
Method Current Sensing in Measurements

• 1.In Line (Max 100A).

• 2. Measurements CT

11
Phase Current Indicating
• 1. Just one phase indicated.(Balanced load)

• 2. Each phase indicated.(Unbalanced Load)


12
Connections of Ammeter in Current
Measurement
• 1. 1CT + Ammeter,Indicates one phase
• 2. 3 CT+ 3 Ammeter
• 3. 3 CT + A/SW+ Ammeter
• 4. 3 CT + 1 Digital Ammeter

13
Ammeter Selector Switch

14
Ammeter Connection
(1 CT + Ammeter,Indicates one phase)

• Sketch Schematic Connection Diagrams and Single line Drawing.

15
Ammeter Connection
(3 CT + 3 Ammeter)

• Sketch Schematic Connection Diagrams and Single line Drawing.

16
Ammeter Connection
(3 CT + A/SW + Ammeter)

• Sketch Schematic Connection Diagrams and Single line Drawing.


17
Ammeter Connection
(3 CT + 1 Digital Ammeter)

• Sketch Schematic Connection Diagrams and Single line Drawing.


18
POWER FACTOR MEASUREMENT

19
Power Factor Meter
• Necessity for measurement : Voltage(V) and Current(I)
• Terminal configuration must refer to instruction manual.

20
Cosideration in Connection for Power Factor Meter

• 1.Three Phase Balanced Load


• 2. Three Phase Unbalanced Load

Terminal configuration must refer to instruction manual.

21
Connection for Power Factor Meter
(Three Phase Balanced Load)

• Sketch Schematic Connection Diagrams and Single line Drawing.


22
Connection for Power Factor Meter
Three Phase Unbalanced /Balanced Load

23
POWER MEASUREMENT

24
Power Meter (W)
• Necessity for measurement : Voltage(V) and Current(I)
• Terminal configuration must refer to instruction manual.

25
Consideration in Connection for Power Meter

• 1. Three Phase Balanced Load (3W)


• 2. Three Phase Unbalanced Load (3W)
• 3. Three Phase Unbalanced Load (4W)

Terminal configuration must refer to instruction manual.

26
Connection for Power Meter(W)
Three Phase Balanced Load (3W)

27
Connection for Power Meter(W)
Three Phase Balanced/Unbalanced Load (3W/4W)

28
Connection for Power Meter(W)
Three Phase Balanced/Unbalanced Load (4W)

29
POWER (Var) METER
• Necessity for measurement : Voltage(V) and Current(I)
• Terminal configuration must refer to instruction manual.

30
Consideration in Connection for Var Meter

• 1. Three Phase Balanced Load (3W)


• 2. Three Phase Unbalanced Load (3W)
• 3. Three Phase Unbalanced Load (4W)

Terminal configuration must refer to instruction manual.

31
Connection for Power Meter(Var)
Three Phase Balanced Load (3W)

32
Connection for Power Meter(Var)
Three Phase Balanced/Unbalanced Load (3W/4W)

33
Connection for Power Meter(Var)
Three Phase Balanced/Unbalanced Load (4W)

34
KWH METER
• Necessity for measurement : Voltage(V) and Current(I)
• Terminal configuration must refer to instruction manual.

35
Connection for KWH

36
FREQUENCY MEASUREMENT

37
Frequency Meter
• Necessity for measurement : Voltage(V)

38
Frequency Meter Connections

39
TEMPERATURE CONTROL IN SWITCH BOARD
(REDUCE MOISTURE IN PANEL)

40
TEMPERATURE CONTROL COMPONENTS

41
Connection Heater Circuit

42
Thanks…..Good Luck