improvements suggested/implemented
• Problem: Internal defect in Rails can only be diagnosed at NDT lab, and un-scanned
part of Rails are highly dangerous.
• Reason diagnosed: To protect damage of Contact probe, UT probe are used after
and before 500-700mm on both ends of Rails. That’s why un-scanned part of 0.5m-
1.0m get passed in 13m Rails.
• Steps Taken to overcome:
– Technical session organised among RITES IEs(UT-II certified) to highlight this point among all.
– Problem conveyed to JSPL QC department(Quality Control Authority).
• Result:- UT scanning of Rails improved:
– Avoiding cutting of Short length pieces(13m) before NDT lab(Non Destructive Testing Lab).
– Long Rail (104m-118m) were cut after NDT lab.
Improvements suggested/implemented
2.1)Achieving hardness for HH Rails(Head Hardened)