You are on page 1of 12

Lamp no. Lamp no.

SID/ Meaning of Display SID/ Meaning of Display


LHB LHB
Lieb lieb
/ /
h h
LEE LEE
err err
L L
Glows when Glows for fault in
K-118 01 K-119 011
controller is healthy AC system

Glows when Fresh/ Glows when Fresh/


K-116 02 Recirculating Air flap K-117 012 Recirculating Air flap
is set at Recirculating is set at Fresh Air
Air
Glows when Glows when
K-113 03 K-114 013
Ventilation-I is Ventilation- II is ON
ON
Lamp no. Lamp no.
SID/ Meaning of Display SID/ Meaning of
LHB LHB Display
Liebh liebh
/ /
err err
LEE LEE
L L
This indication is not Glows when
K-21 04 K-115 014
for AC system Ventilation-II is
ON
Glows during
Glows during cooling
cooling operation
K107 05 operation indicates K-108 015 indicates bypass
bypass cooling in
cooling in Unit-II
Unit-I

Glows during cooling Glows during


operation indicates cooling operation
K-109 06 pressure switch K-111 016 indicates pressure
functional when CD switch functional
1.1 in Unit-I starts. when CD
2.1 in Unit-II starts.
Lamp no. Lamp no.
SID/ Meaning of Display SID/ LHB Meaning of Display
LHB
Liebh liebhe
/ /
err rr
LEE LEE
L L
Glows during cooling Glows during
operation indicates cooling operation
K-110 07 pressure switch indicates pressure
K-112 017
functional when CD switch functional
1.2 in Unit-I starts. when CD
2.2 in Unit-I starts.
Glows during Glows during
K-101 08 cooling operation K-103 018 cooling operation
indicates Comp indicates Comp 2.1
1.1 ON ON
Glows during Glows during
K-102 09 cooling operation K-104 019 cooling operation
indicates Comp indicates Comp 2.2
1.2 ON ON
Lamp no. Lamp no.
SID/ Meaning of Display SID/ LHB Meaning of Display
LHB
Liebh liebh
/ /
e rr e rr
LEE LEE
L L
Glows during Glows during
K-105 010 Heating operation K-106 020 Heating operation
indicates Heater-I, indicates Heater-II,
Unit-I ON
Glows when AC Glows when 415V
K-15 I1 system gets ON K-16 I11 is OK
with switch
S1U4S1
Glows when Glows when
winding winding
temperature of CD temperature of CD
1.1 2.1
K-1 I2 K-3 I12
motor is within motor is within
limit. This light limit. This light
Lamp no. Lamp no.

LHB Meaning of Display LHB Meaning of Display


SID SID
/ /
LEE LEE
L L

Glows when Glows when


winding winding
temperature of temperature of
CD 1.2 CD 2.2
motor is within motor is within
limit. limit.
This light goes This light goes
OFF OFF
K-2 I3 when K-4 I13 when
winding winding
temperature temperature

goes goes
Lamp no. Lamp no.

LHB Meaning of Display LHB Meaning of Display


SID SID
/ /
LEE LEE
L L

This is OFF
when This is OFF when
winding temperature winding temperature of
of Ventilation-II motor is
Ventilation-I within limit. This light
motor is Glows when winding
within limit. This
light temperature goes
K-13 I4 Glows when K-14 I14 beyond limit & the AC
winding Unit-II also goes out of
temperature service.

goes
beyond limit & the
Lamp no. Lamp no.

LHB Meaning of Display Meaning of Display


SID
/ LHB
LEE SID
/
L LEE
L
Glows when LP is OK.
This light goes OFF Glows when LP is OK.
when pressure at LP This light goes OFF
when
switch of refrigerant pressure at LP switch of
circuit 1.2 goes down refrigerant circuit 2.2
K-8 I7 K-12 I17 goes
and switches off
down and switches off
refrigerant circuit 1.2 refrigerant circuit 2.2 if
if
the pressure remains the pressure remains low
low for more then 30 for more then 30
Lamp no. Lamp no.
LHB Meaning of LHB Meaning of
SID Display SID Display
/ /
LEE LEE
L L
Glows when Glows when
Control pressure Control pressure
switch-1 is ON, switch-2 is ON,
which means HP which means HP
is more then 25 is more then 25
K-19 I8 bar which will K-20 I18 bar which will
automatically run automatically
run
second condenser second
motor. condenser motor.
Lamp no. Lamp no.
Meaning of Display Meaning of
SID LHB SID LHB
Display
/ /
LEE LEE
L L

This will Glow


This will Glow when HP gets
when HP gets more then
more
then setting of HP setting of HP
cut
K-5 I9 cut out switch 1.1 K-9 I19 out switch 2.1
and the and the
compressor
1.1, Unit-I will get compressor 2.1,
Lamp no. Lamp no.
LHB/ Meaning of LHB/ Meaning of
SID Display SID Display
LEEL LEEL

This will Glow


This will Glow
when HP gets
when HP gets more then
more then setting of HP
setting
cut out switch
of HP cut out
K-7 I10 K-11 I20 2.2 and the
switch 1.2 and
compressor
the compressor
2.2, Unit-II
1.2, Unit-II will will get OFF
get OFF
Figure : Outer View of EOG AC Chair
Car

You might also like