MINIMUM SEWER SIZE: 225mm is taken as the minimum sewer size. The reason
being that, the choking does not take place even with the bigger size particles, which
are usually thrown into the sewer through manholes.
SPACING OF MANHOLE: Fol spacing are considered sufficient for maintenance
view point:
For 9” to 15” Pipe = >100m
For 18” to 30” Pipe = upto 120m
For more than 30” Pipe = upto 150m
DIRECTION OF SEWER LINE:
Sewer should flow, as for as possible the Natural Slope.
Hydraulic Elements–of
Flow Velocity Partially
Sewer SizeFlowing
– Invert Sewer
Lvl
INVERT LEVEL 4
The lowest inside level at any cross-section of a sewer pipe is known as Invert Level
at that Cross-section.
Invert Level = NGL/Road Level – Depth of Sewer – Thickness of Sewer – Dia. of
Sewer