Megatech Global Engineering Services is a leading underwater Air & Mix Gas diving services provider to offshore/
onshore construction and subsea services to the Oil & Gas Industry in the India and other Subcontinents. Since the
establishment in 2007, Integrated diving operates through its operational base located in Mumbai, India, which is the
main center of offshore activities.
Megatech Global Engineering Services is successfully managed by team of professionals, who are Qualified as
Clearance Diver, ADAS/IMCA Part-I, Sat Diver, N.D.T. Engineer (U.K, Australia and south Africa), with vast experience
of 22 years in subsea industry - Ex-Indian Navy personnel. We have significant expertise in the management of
fast track projects from design to completion.
Megatech Global Engineering Services has access to a wide range of diving units for shallow and deep-water
intervention, underwater hydraulic & Pneumatic tools and NDT equipment and number of Diving spread for
all construction and installation works.
Industrial Radiography
(Approved by eLORA - A.E.R.B)
Industrial Radiography
• LICENCE FOR OPERATION OF INDUSTRIAL RADIOGRAPHY FACILITY
Case File Number:- MH-109764-INST (Date of Expiry :13/06/2026)

• APPROVAL FOR SOURCE STORAGE FACILITY


Case File Number: MH-109764-INST (Date of Expiry :31/12/2025)

• APPROVAL OF RADIOLOGICAL SAFETY OFFICER


Case File Number: MH-109764-INST (Date of Expiry :09/01/2026)
Industrial Radiography

CERTIFIED TEAM SAFETY OF OPERATORS


• RSO • SURVEY METER
• SITE-INCHARGE/RADIOGRAPHER • DOSIMETER
• TRAINEE • TLD
• C V TONGE
• RED WARNING LIGHTS
• RADIATION FLAGS
• AERA CORDONING ROLL
Radiography Safety Tools
Radiography Device
Radiography Camera Assembly
Radiography Camera Functional Activity
Radiation Safety
Specific Safety Requirements
• Radiography camera to be operated by only certified Radiographers.

• Field radiography to be carried out during night time when there is no occupancy.

• An Appropriate area around the radiation source must be cordoned off during
radiography.

• Radiation Level to be monitored by suitable & Calibrated Radiation Survey Meter.

• Radiation Warning Symbols to be Posted along the cordon.


Specific Safety Requirements
• Unauthorized persons to be prohibited during exposure.

• Red warning light to be displayed during night along cordon, especially at


the point of entry.

• Concerned Radiographer to be planned in advance & executed in minimum


possible time.

• After Completion of Each exposure, source pencil must be securely locked


in the camera.
Radiation Safety
• What is cordon off distance?
How far the public to be blocked from the radiography process, in the case of industrial radiography is cleared by the
concept called corden-off distance

Controlled Area – Radiation for Radiographer


7.5 micro sievert /hr

Supervised Area- Radiation for General Public


2.5 micro sievert/hr (Allowable Radiation for 8 hrs Exposure)