EXCRETA
drainage
system
Chapter 7
INTRODUCTION
The excreta drainage system is a vital
part of a building's plumbing,
responsible for safely removing waste
and wastewater from toilets, sinks, and
showers. It uses pipes and fittings to
transport waste to the sewer system,
ensuring sanitation and preventing health
risks.
Materials
Fixture unit equivalent
Size of drainage piping
Fixture connections (Excreta Drainage)
Changes in Direction of Excreta Drainage Flow
TABLE
OF CONTENT
Cleanouts
Grade of Horizontal Excreta Drainage
Piping
Gravity Drainage Required
Drainage of Fixtures Located Below the
Upstream Manhole or below the Main
TABLE
Sewer Level OF CONTENT
Suds Relief
materials
PIPINGS
•Cast iron
•Ductile iron
•Galvanized steel
•Galvanized wrought iron
•Lead
•Copper
•Brass
•Series 1000 PVC DWV
•Extra-strength vitrified clay pipe
•Other approved materials
EXCEPTIONS
No galvanized ABS and PVC DWV No vetrified clay pipes
wrought iron or piping installations or fittings for building
galvanized steel pipe shall be used in high- drain or sewer shall be
shall be used rise buildings, provided used above ground or
underground and shall that its use shall be the whenever piping is
be kept at least discretion of the Master pressurized by a pump
Plumber/ Designer and or ejector. They sall be
152mm above ground.
also with the full kept at least 0.3 meter
consent of the owner. below finish ground
level.
materials
Drainage fittings shall be of cast iron, malleable iron, lead,
brass, copper, ABS PVC, vitrified clay, or other approved
materials having a smooth interior waterway of the same
diameter as the piping served and all such fittings shall be
compatible with the type of pipe used.
Fittings on screwed pipe joints shall
be of the recessed drainage type.
Burred ends shall be reamed to the
full bore of the pipe
materials
Item
Pipe Size Fixture Unit F.U.
No.
1 32 1
2 38 3
3 51 4
4 76 6
EXCEPTION:
5 102 8 On self-service laundry
size of drainage
piping
Size
drainage piping
The minimum sizes of vertical and/or horizontal drainage
pipings shall be determined from the total of all fixture
units connected thereto, and additional, in the case of
vertical drainage pipes, in accordance with their height or
length.
discrarge capacity
Item
Liters per Second (L/S) Fixture Unit (F.U.)
No.
1 Up to 0.47 1
2 0.50 to 0.95 2
3 1 to 1.89 4
4 1.95 to 3.15 6
For Intermittent Flow Only
fixture
connections
Drainage piping shall be provided with
approved inlet fittings for fixture connections,
excreta
correctly located according to the size and
type of fixture proposed to be connected.
drainage
excreta
Two fixtures set back-to-back, or side-by-
side, within the distance allowed between a
trap and its vent, may be served by a single
vertical drainage pipe, provided that each
fixture wastes separately into an approved
doubble fitting
drainage
changes in direction of
excreta
drainage flow
Changes in direction of drainage piping shall be made by the
appropriate use of approved fittings and shall be of the
angles presented by a 22 1/2° or 1/16 bend, 45° or 1/8 bend,
60° or 1/6 bend or other approved fittings of equivalent
sweeps
horizontal drainage branch line
connections guiidlines
entry fittings fitting types no cross-contaminations
Horizontal drainage branch lines The approved fittings include 45° Fittings with multiple inlets at
connect to vertical stacks via or 60° wye branches, combination the same level can't be used
specific fittings. wye and 1/8 bend branches,
unless designed to prevent
sanitary tee or sanitary tapped tee
cross-contamination between
branches, or equivalent approved
fittings. inlets.
38 38 11-1/2
51 38 11-1/2
64 64 8
76 64 8
which have flood level rims located below the elevation located below the crown level of the main sewer
of the nearby upstream manhole invert of the public shall discharge into an approved watertight sump
sewer or receiving tank, the sewage or other liquid wastes
serving such drainage piping shall be protected from shall then be lifted and discharged into the building
backflow of sewage by installing an approved-type drain or building sewer by approved ejector, pump
backwater valve. Fixture installed above such or other equally efficient mechanical device.
elevation shall not discharge through the backwater
valve.
Suds Relief
Fixture outlets shall not be connected to the horizontal excreta
drainage piping system within 2.4 meter of any vertical to horizontal
change of direction of a stack containing suds-producing fixtures.
Bathtubs,
laundries, washing machine standpipes, kitchen sinks and
dishwashers shall be considered suds-producing fixtures.
Exceptions
(a) Single family residences.
(b) Stacks receiving the discharge from less than (3) stories of
plumbing fixtures
End of
Discussion
What is the primary purpose of the excreta
05 How does the excreta drainage system connect to the municipal sewage
system or septic tank?
To safely transport wastewater and sewage
Answers
A vent pipe prevents vacuum effects, maintains
03 trap seals, and eliminates foul odors in the
drainage system.
A trap is a U-shaped pipe under fixtures that prevents sewer gases from
entering while allowing wastewater to flow.
04