Professional Documents
Culture Documents
The history
1970-1982
1970-1982 DataChief
DataChief I,I, II
II and
and III
III
Centralised
CentralisedAlarm,
Alarm,Monitoring
Monitoringand
andControl
Controlsystem
system
Deliveries
Deliveriesto
to100
100vessels
vessels
Pioneers
Pioneers
1982-
1982- 1999
1999 DataChief
DataChief 7,
7, 1000
1000 and
and 2000
2000
Distributed
DistributedAlarm,
Alarm,Monitoring
Monitoringand
andControl
Controlsystem
system
Microprocessor,
Microprocessor,colour
colourgraphics
graphics
Deliveries
Deliveriestoto2000
2000vessels
vessels
1999
1999 -- 2006
2006 DataChief
DataChief C20
C20
Highly
HighlyDistributed
DistributedAlarm
AlarmMonitoring
Monitoringand
andControl
Controlsystem
system
No
Nocentral
centralcomputer
computer
High
Highspeed
speedredundant
redundantfield
fieldbus
bus
Deliveries to 1500 vessels
Deliveries to 1500 vessels
2007
2007 ->
-> K-Chief
K-Chief 500
500
Updated
Updatedpresentation
presentationSW
SW
New
NewOperator
OperatorControl
ControlPanel
Panel
KONGSBERG May 27, 2008 1
The K-Chief automation concept
Alarm monitoring
Machinery control
Power management
Propulsion control
Cargo & ballast monitoring and control
Information management
Ship-shore communication
Remote diagnostics
Individual systems
One solution
Modular Functionality
– Modular hardware and software
– Software independent of hardware
– “LEGO” hardware by flexible DPU’s
– “LEGO” software by function modules
Modern technology
– Commercial “off-the-shelf” (COTS) technology
– Type approved computer (Intel Pentium)
– Windows XP operating system
– Distributed process control and signal processing
– Single board DPU’s “Intelligent junction boxes”
– Redundant Control Area Network (field bus; CAN)
AD-
AD- 0424
0424
AD-
AD- 0282
0282 DPU RDi-32 / RDi-32a
AD-
AD- 0283
0283 DPU RDo-16
AD-
AD- 0281
0281 DPU Rai-16
AD-
AD- 0289
0289 DPU RAo-08
AD-
AD- 0294
0294 DPU Rai-10tc
AD-
AD- 0327
0327 Process Segment Star coupler PSS
AD-
AD- 0296
0296 dual Process Segment Controller dPSC
Applications:
– Alarm and Monitoring
– Auxiliary Control
– Power Management
– Cargo Monitoring
– Cargo and Ballast Control
– HVAC Automation (Air Condition)
– Management Support
Features PDG
- Compressor control
OS 1 OS 2 CONTROL CONTROL OS 3 OS 4
ROOM ROOM
- Purifier control
- Boiler control DUAL LAN
HUB
DUAL LAN
- Heeling control
HUB
- Power Management
LOS LOS LOS LOS
Alarm Sensors Alarm Sensors
DPU DPU
Local DPU DPU
Local
Operating Operating
DPU DPU Station DPU DPU Station
(LOS) (LOS)
DPU DPU DPU DPU
Redundancy
- Fully redundant controller area
network (CAN); fast, robust and
reliable
- Scaleable redundancy tailored
to vessels’ design
- dPSC provides full segmentation
with logical and galvanic isolation
- PSS provides star topology with
galvanic isolation
- A truly scaleable hierarchical and
segregated network
- Event based, local time stamp,
immediate transfer of data
- Instant and up to date
information available at any time
Extract of redundant propulsion
Mimic on Site
- Possible to modify
mimic picture when
the system is
running by
commissioning eng.
- Mimic editor
installed on OS
- Automatic update
to all computers
- The view is
displaying mimic
editor
List view
- Shaded lines
- Possible to sort on all columns
Short trend
- 24 hours history
- Log all changes
for all tags (I/O
and SW) the last
24 hours
- Possible to store
10 individual
hours with data
- Save screen dump
- No need for
selecting tags
Long trend
Pdf viewer
- Instruction manual
following SP
- Possible to add pdf
files to document
folder
- Not possible to
access file system
- Easy search and
zoom
- Printout facility if
suitable printer
Operator panel to be
used on Bridge
K-Chief 500
Tank
calculation Load
in OS Computer
OS OS
NCA DL-94
MSI
RCU
Dual CAN
LAN
DPU
GLK GLK GLK
DPU
K-Chief
K-Chief 500
500
-- flexible
flexible installation
installation
No centralised processing
AD-
AD- 0352
0352 System information display
AD-
AD- 0349
0349 Monitor & OCP dimmer display
AD-
AD- 0341
0341 Alarm summary display
AD-
AD- 0340
0340 Alarm history display
AD-
AD- 0342
0342 Autolog display
AD-
AD- 0353
0353 Tag details display
AD-
AD- 0339
0339 Selected points log display & configuration
AD-
AD- 0336
0336 Selected points bargraph display & configuration
AD-
AD- 0337
0337 Selected points trend display & configuration
AD-
AD- 0345
0345 Exhaust gas temp deviation
AD-
AD- 0348
0348 Misc, log display
AD-
AD- 0406
0406 Inhibit tags display
AD-
AD- 0407
0407 Offscan tags display
ROS
ROS
AD-
AD- 0330
0330 Positioner handler
AD-
AD- 0331
0331 PID controller
AD-
AD- 0332
0332 Stand-by pump handler
AD-
AD- 0333
0333 Starter handler
AD-
AD- 0335
0335 Performance monitoring system
AD-
AD- 0344
0344 Counter display
AD-
AD- 0350
0350 OCP display
AD-
AD- 0351
0351 Ships display
AD-
AD- 0347
0347 Level correction display
AD-
AD- 0346
0346 General tank display
AD-
AD- 0343
0343 Cargo tank density
ROS
ROS
AD-
AD- 0356
0356 Lub. oil service system
AD-
AD- 0358
0358 Fuel oil service system
AD-
AD- 0357
0357 Cooling fresh water system
AD-
AD- 0359
0359 Sea water system
AD-
AD- 0355
0355 Inert gas system
AD-
AD- 0354
0354 Ballast system
AD-
AD- 0193
0193 Generator control system
AD-
AD- 0157
0157 Power management system, one touch auto sequence
AD-
AD- 0373
0373 Heating, ventilation & air conditioning (HVAC)
AD-
AD- 0417
0417 Selected cargo pumps display
ROS
ROS
AD-
AD- 0366
0366 Ferries & Passenger vessels
AD-
AD- 0367
0367 Gas carrier
AD-
AD- 03680
03680 Chemical tanker
AD-
AD- 0369
0369 Oil tanker
AD-
AD- 0370
0370 Container vessel
AD-
AD- 0371
0371 Bulk carrier
AD-
AD- 0372
0372 Ro-Ro vessel
AD-
AD- 0372
0372 Small vessels