DPP vs Pumping Time Waktu ketika kick sampai permukaan:

t=

V AN Vkick ( 483.205 15) bbl = 156.068 = minutes ( 3 BPM ) pump rate

Jadi, kick sampai permukaan pada menit ke 156.068 minutes. Waktu untuk mendisplace kick di anulus:

t=

V AN ( 483.205 bbl ) = 161.068 = minutes ( 3 BPM ) pump rate

Jadi, kick keluar dari anulus pada menit ke 161.068 minutes. Waktu untuk mengisi mud baru di dalam drillstring (surface until bit):

t=

V DS (137.58 bbl ) = 45.86 = minutes ( 3 BPM ) pump rate

Cumulative time = 161.068 + 45.86 = 206.928 minutes So, the time required to deliver the new mud to the bit is 206.928 minutes. Waktu untuk mengisi mud baru di anulus:

t=

V AN ( 483.205 bbl ) = 161.068 = minutes ( 3 BPM ) pump rate

Cumulative time = 206.928 + 161.068 = 367.996 minutes. So, total time required to circulate the new mud is 367.996 minutes. ICP (Initial Circulating Pressure) FCP (Final Circulating Pressure) = SIDP + Ploss = 400 + 500 = 900 psi. = Ploss

mb 10.67 = 500 x = 555.73 psi ml 9.6

Pressure drawdown when killing mud is being circulated into the drillstring :

DPP = ICP FCP = 900 555.73 = 344.27 psi


Rate of pressure drawdown when killing time :
344.27 psi dP DPP = = = 7.51 psi / menit dt total time 45.86 menit

Calculation : @ 0 161.068 minutes DPP = ICP = 900 psi (constant) @ 161.068 206.928 minutes Pressure drawdown is 7.51 psi/minute, thus every minute, the pressure decreases 7.51psi. To determine DPP is :

DPP = 900 7.51 x ( time 161.068) psi

@ 206.928 367.996 minutes DPP = FCP = 555.73 psi (constant).

DPP vs Strokes Jumlah stroke untuk mengisi mud baru di dalam drillstring:
Stroke = V DS 137.58 bbl = = 1376 strokes disp 0.1 bbl / st

Jadi, mud baru sampai di bit pada stroke ke 1376 strokes Jumlah stroke ketika kick sampai permukaan:
Stroke = V AN Vkick ( 483.205 15) bbl = 4682 = strokes disp 0.1 bbl / st

Jadi, kick sampai permukaan pada stroke ke 4682 strokes Jumlah stroke untuk mendisplace kick di anulus:
Stroke = V AN 483.205 bbl = = 4832 strokes disp 0.1 bbl / st

Jadi, kick keluar dari anulus pada stroke ke 4832 strokes Jumlah stroke untuk mengisi mud baru di anulus:
Stroke = V AN 483.205 bbl = = 4832 strokes disp 0.1 bbl / st

Cumulative strokes = 1376 + 4832 = 6208 strokes Jadi, mud baru sampai ke permukaan lagi pada stroke ke 6208. Contoh perhitungan: pada stroke 0 1376
DPP FCP ICP 555.73 900 = = = 0.25 psi stroke stroke St final St initial 1376 0

Tiap 1 stroke, DPP turun 0.25 psi, sehingga mencari DPP sbb:
DPP = 900 0.25 x ( Strokes )

pada stroke 1376 - 6208


DPP = FCP = 555.73 psi (constant)

DPP vs Pumping time

Waktu ketika kick sampai permukaan:

t=

V AN Vkick ( 483.205 15) bbl = 156.068 = minutes ( 3 BPM ) pump rate

Jadi, kick sampai permukaan pada menit ke 156.068 minutes. Waktu untuk mendisplace kick di anulus:

t=

V AN ( 483.205 bbl ) = 161.068 = minutes ( 3 BPM ) pump rate

Jadi, kick keluar dari anulus pada menit ke 161.068 minutes. Waktu untuk mengisi mud baru di dalam drillstring (surface until bit):

t=

V DS (137.58 bbl ) = 45.86 = minutes ( 3 BPM ) pump rate

Cumulative time = 161.068 + 45.86 = 206.928 minutes So, the time required to deliver the new mud to the bit is 206.928 minutes. Waktu untuk mengisi mud baru di anulus:

t=

V AN ( 483.205 bbl ) = 161.068 = minutes ( 3 BPM ) pump rate

Cumulative time = 206.928 + 161.068 = 367.996 minutes. So, total time required to circulate the new mud is 367.996 minutes. ICP (Initial Circulating Pressure) FCP (Final Circulating Pressure) = SIDP + Ploss = 400 + 500 = 900 psi. = Ploss

mb 10.67 = 500 x = 555.73 psi ml 9.6

Pressure drawdown when killing mud is being circulated into the drillstring :

DPP = ICP FCP = 900 555.73 = 344.27 psi


Rate of pressure drawdown when killing time :
344.27 psi dP DPP = = = 7.51 psi / menit dt total time 45.86 menit

Calculation : @ 0 161.068 minutes DPP = ICP = 900 psi (constant) @ 161.068 206.928 minutes Pressure drawdown is 7.51 psi/minute, thus every minute, the pressure decreases 7.51psi. To determine DPP is :
DPP = 900 7.51 x ( time 161.068) psi

@ 206.928 367.996 minutes DPP = FCP = 555.73 psi (constant).

DPP vs Strokes Jumlah stroke untuk mengisi mud baru di dalam drillstring:
Stroke = VDS 137.58 bbl = = 1376 strokes disp 0.1 bbl / st

Jadi, mud baru sampai di bit pada stroke ke 1376 strokes Jumlah stroke ketika kick sampai permukaan:
Stroke = V AN Vkick ( 483.205 15) bbl = 4682 = strokes disp 0.1 bbl / st

Jadi, kick sampai permukaan pada stroke ke 4682 strokes Jumlah stroke untuk mendisplace kick di anulus:
Stroke = V AN 483.205 bbl = = 4832 strokes disp 0.1 bbl / st

Jadi, kick keluar dari anulus pada stroke ke 4832 strokes Jumlah stroke untuk mengisi mud baru di anulus:
Stroke = V AN 483.205 bbl = = 4832 strokes disp 0.1 bbl / st

Cumulative strokes = 1376 + 4832 = 6208 strokes Jadi, mud baru sampai ke permukaan lagi pada stroke ke 6208. Contoh perhitungan: pada stroke 0 1376
DPP FCP ICP 555.73 900 = = = 0.25 psi stroke stroke St final St initial 1376 0

Tiap 1 stroke, DPP turun 0.25 psi, sehingga mencari DPP sbb:
DPP = 900 0.25 x ( Strokes )

pada stroke 1376 - 6208


DPP = FCP = 555.73 psi (constant)