File:C:\Users\minedu\Documents\EES\ejemplo7.

EES
03/06/2013 08:12:35 p.m. Page 1
EES Ver. 9.215: #3470: For use only by students and faculty in the Departamento de Ingenieria Mecanica Universidad de Za

"Programa de calculo de un ciclo de Refrigeracion"


"Programado por XRSA - Octubre 2013"
"Datos de entrada"
Q_dot_evap=0.88[kW] "Capacidad de enfriamiento del evaporador"
P_alta=11*convert(bar,kPa)
P_baja=2*convert(bar,kPa)
"Refrigerante R-134a"
"Evaporador"
P[3]=P_baja
x[4]=1
P[4]=P_baja
h[4]=Enthalpy(R134a,P=P[4],x=x[4])
T[4]=T_sat(R134a,P=P[4])
x[3]=Quality(R134a,P=P[3],h=h[2])
T[3]=T[4]
Q_dot_evap=m_dot_R*(h[4]-h[3])
s[3]=Entropy(Acetone,T=T[3],x=x[3])
v[3]=Volume(R134a,T=T[3],x=x[3])
"Valvula de Expansion"
h[2]=h[3]
P[2]=P_alta
x[2]=0
T[2]=T_sat(R134a,P=P[2])
h[2]=Enthalpy(R134a,P=P[2],x=x[2])
v[2]=Volume(R134a,T=T[2],x=x[2])
s[2]=Entropy(R134a,T=T[2],x=x[2])
"Condensador"
P[1]=P_alta
v[4]=Volume(R134a,x=x[4],P=P[4])
T[1]=Temperature(R134a,P=P[1],h=h[1])
v[1]=Volume(R134a,T=T[1],P=P[1])
"Compresor"
W_dot_comp=m_dot_R*(h[1]-h[4])
s[1]=s[4]
s[4]=Entropy(R134a,P=P[4],x=x[4])
h[1]=Enthalpy(R134a,P=P[1],s=s[1])
x[1]=Quality(R134a,T=T[1],s=s[1])
"Rendimiento"
BETA=Q_dot_evap/W_dot_comp

SOLUTION
Unit Settings: SI C kPa kJ mass deg
m R = 0.006677 [kg/s]
b = 3.707
Qevap = 0.88 [kW]
W comp = 0.2374 [kW]

Palta = 1100 [kPa]

No unit problems were detected.


Arrays Table: Main

1
2

Pi

Ti

hi

vi

si

xi

[kPa]

[C]

[kJ/kg]

[m3/kg]

[kJ/kg*K]

[-]

1100
1100

49.51
42.95

280
112.7

0.01924
0.0008818

0.9379
0.4088

100
0

Pbaja = 200 [kPa]

File:C:\Users\minedu\Documents\EES\ejemplo7.EES
03/06/2013 08:12:35 p.m. Page 2
EES Ver. 9.215: #3470: For use only by students and faculty in the Departamento de Ingenieria Mecanica Universidad de Za

Arrays Table: Main

3
4

Pi

Ti

hi

vi

si

xi

[kPa]

[C]

[kJ/kg]

[m3/kg]

[kJ/kg*K]

[-]

200
200

-10.09
-10.09

112.7
244.5

0.03652
0.09995

1.7
0.9379

0.3605
1