Professional Documents
Culture Documents
Porous Pin Fin
Porous Pin Fin
INTRODUCTION
1.1 INTRODUCTION
Electronic devices need highly effective cooling technology for ensuring their
excellent performance and reliability at all operating conditions. This is very
significant in recent electronic innovations. Because nowadays size of electronic
appliances is becoming far small, and consequently volume decreases to a large
extent. But their heat generation remains the same for that particular application.
This results in the fact that effective heat generation per unit volume of the
electronic device increases drastically. Hence to transfer the heat generated in
small volume is the most challenging task in front of designers.
If heat transfer mechanism is not effective, it can result in excessive
heating of electronic devices. This may lead to serious problems which will make
the device non-functional. Excessive heat generation will result in abnormal
operating temperature which can damage the entire electronic circuits. Such high
temperatures will cause the burn out of components. Also high temperature will
decrease the reliability of the device. Especially in case of measuring devices,
controlling devices etc. accuracy of operation is getting reduced which will cause
serious faulty outcomes. A 10 degree rise in the temperature can reduce the
reliability of an electronic device to half of its original value.
Fins or extended surfaces are one of the technologies used in transferring
heat generated in electronic devices. As the heat generation per effective volume
increases ordinary fins may be inappropriate to transfer the excess heat.
Increasing the length of the fin beyond a critical value will decrease the heat
transfer rate. Besides this, large fins are difficult to be accommodated in small
electronic device. We cannot allocate more volume or size only for the purpose of
cooling. An effective electronic cooling systems must be capable of transferring
more heat using limited available size and must be light weight, low cost and
compatible with the design of the device in which it is to be used. So the task is to
1
increase heat transfer rate for a specified fin volume or to decrease fin volume for
a given heat transfer rate.
1.1
1.2
PROBLEM DEFINITION
In this study, an analytical methodology followed by Adomian
decomposition method is applied to solve the nonlinear class of governing energy
equations of a porous pin fin attached to a vertical isothermal wall. Darcy model
is used to analyse the porous pin fin. Governing energy equations are formulated
using the Darcy model and
The present approximate analytical technique is a very useful and practical
method for solving any class of nonlinear governing equations without adopting
linearization or perturbation technique. It provides an analytical solution in the
form of power series where the temperature on the fin surface can be expressed
explicitly as a function of position along the length of the fin. Thus, the
temperature distribution and its performances are easily being determined for a
wide range of design variables of porous fins.
CHAPTER 2
LITERATURE REVIEW
Kundu and Bhanja [1] developed an analytical model for determination of the
performance and optimum dimensions of porous fin of rectangular shape. Recently,
Kundu et al. [2] worked on the performance and optimum design analysis of porous fin of
various profiles operating in convection environment.
Yu and Chen [3] performed a study on optimization of circular fin with variable
thermal parameter. Saedodin and Olank [4] investigated the temperature distribution over
fin surface and compared the results with conventional fins. For the analysis they have
selected a pin fin subject to heat transfer in natural convection condition.
ADM (Adomian polynomial method) [5] is employed to solve differential
equations which gives accurate results than ordinary Taylor series expansion.
CHAPTER 3
MODELLING OF THE PROBLEM
3.1 MODEL
Figure given below shows a straight porous pin fin having uniform cross-section,
length L and diameter D. Fin is attached to a vertical isothermal wall. Heat flow is
directed from the wall to the fin by means of conduction and from fin to atmosphere
through natural convection .Surrounding fluid (air) can penetrate into fin interior since
the fin is provided with numerous pores. The porous fin increases the effective surface
area of the fin through which the fin convects heat to the working fluid (air).
Fig 3.1
3.2 ASSUMPTIONS
For making the analysis convenient, following assumptions were made:
Void spaces inside the porous fin are saturated with working fluid (air) which
exists in single phase.
All physical properties of both solid and fluid medium are taken as constants
except for density of fluid which may vary with temperature.
To enable the model analysing the interaction of a fluid with porous medium,
Darcy formulation is adopted for modelling.
The temperature inside the fin is only function of distance from the wall along
its length.
There are no heat sources in the fin itself and no contact resistance at the fin
base (heat generation is zero).
to it.
Total convective heat transfer from the porous fin is taking place in two ways. First
way is natural convection between solid surface and ambience. This is common to all
fins irrespective of their type. Second way is peculiar to porous fins which is the main
factor that increases heat transfer rate in porous fins. This is due the interaction of
fluid particles penetrating through porous medium with solid fin material. Darcys
law should be applied to calculate heat transfer due to this method. Total heat transfer
from fin surface is the sum of heat transfer due to both methods. By applying an
energy balance to the differential segment of the porous fin with considering only
convection, mathematically it yields
( )
)(
(1)
Here in RHS, first term comes from the Darcy model and second term is applicable
for any fin with insulated tip and finite length, but multiplied by a factor
. This
factor is used because some area is not available for heat transfer because of porosity.
From Darcys formulation we get,
Mass flow rate of fluid passing through pores,
(2)
))
} (3)
Now substituting these values to eq. (1), we can rewrite the LHS of it, by applying
6
Fouriers law of conduction. This is purely based on the assumption that heat transfer
rate through the solid due to conduction is balanced by the total convective heat
transfer rate. That is, all heat conducted is dissipated to atmosphere by convection.
Now,
( )
( )
Now dividing by
)(
Eq. (6) is the one dimensional energy equation of porous pin fin.
( )
CHAPTER 4
NON-DIMENSIONALISATION (SCALING)
4.1 INTRODUCTION
Some quantities are better measured relative to some other appropriate unit called
quantities intrinsic to the system. This can recover the characteristics properties if the
system. Also it is very useful where systems are described by differential equations.
Using non dimensionalisation, measurement in one system can be compared with
common property measurement in other system which has same intrinsic property as the
first system. This technique, can suggest the parameters which should be used to analyse
the system. But anyway a starting equation is needed.
4.2 STEPS IN NON DIMENSIONALISATION
(
(
)
)
]
(
( )
)
( )
(
( )
(
8
And
,
( 2)
Fin Efficiency
Fin Effectiveness
(
*
)
(
)+
)
(
Fin Efficiency,
Fin Effectiveness,
9
CHAPTER 5
ADOMIAN DECOMPOSITION METHOD (ADM)
5.1 ADM
ADM is a modern methodology employed to solve governing equations of many
current systems. They are preferred over Taylors series expansion nowadays. ADM was
developed by mathematician George Adomian during 1970-1990.
The ADM which can accurately compute the series solution, is of great interest to
applied sciences. The method can provide the resulting solution as a quickly converging
series with components that are elegantly computed.
Advantages of this method over other methods are I can be applied to any
differential or integral equations without considering whether they are
linear or nonlinear
homogeneous or inhomogeneous
Besides this, this method is highly capable of minimizing the size of computation
work while still maintaining high accuracy of the numerical solution.
5.2 GENERAL FORM OF ADM
Let there be a differential equation say,
, such that
exists and
( )
So
) (2 )
10
( )
( )
(22)
And
(2 )
Also
(
(2 )
(2 )
Using Eqs. (9)- (11), non-dimensional temperature expression ( ) can be found out as,
( )
(2
(2 )
Now from Eq. (26) we can get the non-dimensional temperature distribution of porous
pin fin in terms of non-dimensional wall temperature
11
CHAPTER 6
RESULTS AND DISCUSSION
Fig 6.1
Fig 6.1 shows variation of dimensionless temperature
X with various other parameters like Da, Nu,
and .
Fig. 6.1 (a) shows that with dimensionless distance X, dimensionless temperature
decreases and this decrease is rapid when Ra value is increased. From definitions of Ra,
it can be understood that high Ra value favours convective heat transfer. So with increase
in Ra number, heat transfer rate increases which results in sudden lowering of
temperature across fin length.
12
Same variation can be seen with porosity parameter . But it is an ideal concept.
Increase in porosity can augment heat transfer rate only up to a certain limit. Actually, a
high porosity decreases the effective thermal conductivity of the porous fin due to the
removal of solid material and thus maintains lower temperature at the fin tip. Fig. 6.1 (b)
shows that dimensionless temperature increases with the increase of thermal conductivity
ratio
conductive material which can maintain tip temperature very highand augments the rates
of heat transfer. But variation with Nu predicts a reverse trend.
Fig 6.2
The effect of porosity parameter and Nusselt number on fin performance as a
function of geometric parameter is envisioned in Fig. 6.2. Both the fin performances are
dropped with the increase of these parameters. High value of porosity parameter not only
decreases the effective thermal conductivity but also reduces ideal heat transfer as
defined in Eq. (16) and (17). But the impact of this parameter is not so influential with
low Nu. Thats why both fin efficiency and effectiveness decline with increasing.
Moreover, ideal heat transfer rate also decreased with the increase of Nu as defined in Eq.
(16) and (17) and thus performance is decremented.
On the other hand both fin efficiency and effectiveness enhance with the
geometric parameter . The value of parameter can be increased either byincreasing the
radius or by decreasing length of the fin. As the entire fin length cannot be effectively
utilized dueto conductive resistance of the fin material thus the fin having smaller length
always transfers better heat and thus fin performance become high.
13
Fig 6.3
Fin performances as a function of porosity parameter and Darcy number is shown
in Fig. 6.3. The main view point behind using porous fins is to increase the effective
surface area through which heat is convected to the surrounding fluid. When the value
of
14
Fig 6.4
Fig. 6.4 (a) shows the effect of Da and Nu on temperature gradient at fin base as a
function of . As mentionedearlier that a high Da number indicates mainly high
permeability of the porous fin which means more working fluid can pass through it and
thus creates a higher temperature gradient at the fin base. Porous fins having small Da
number behave as solid fins due to their small permeability. The effect of Nu number also
shows the same trend because it increases the heat transfer coefficient over the fin
surface. On the other hand, the dimensionless actual heat transfer rate through the porous
pin fin surface as a function of, Ra and
figure that actual heat transfer rate enhances with the increase of these parameters. For a
particular fluid, with increasing the parameter , thermal conductivity of the fin material
is also increased that reduces theconductive resistance in the fin surface and thus heat
transfer rate is enhanced.
15
CHAPTER 7
CONCLUSIONS
An effort has been made to determine the temperature distribution, fin performance and
heat transfer rate over a straight porous pin fin that may help in optimum design analysis.
The fin dissipates heat to the environment through natural convection. For the
aforementioned conditions, an approximate analytical technique, namely ,Adomian
decomposition method (ADM) has been proposed for the solution of governing fin
equation. This method provides solution in the form of infinite power series and it has
high accuracy and fast convergence. Thus ,fin performance parameters and heat transfer
rate can easily be obtained from the explicit form of the temperature distribution. The
following concluding remarks can be drawn from the present study:
Temperature distribution in the porous pin fin is highly dependent upon the
related parameters. A higher tip temperature is maintained with the low value of
the parameters Da, Ra and Nu whereas the parameter shows a reverse trend.
Actual heat transfer rate is enhanced with the increase of the parameters, Ra and
.
16
REFERENCES
1) Dipankar Bhanja, Balaram Kundu, Kwan-Soo Lee- A model on the basis of
analytics for computing maximum heat transfer in porous fins- International
Journal of Heat and Mass Transfer 55 (2012) 76117622
2) Dipankar Bhanja, Balaram Kundu- An analytical prediction for performance and
optimum design analysis of porous fins- international journal of refrigeration 34
(2011) 337-352
3) Yu, L.T., Chen, C.K., 1999. Optimization of Circular Fins with Variable Thermal
Parameters, Journal of Franklin Institute 336, p. 77
4) Saedodin, S., Olank, M., 2011. Temperature Distribution in Porous Fins in
Natural Convection Condition, Journal of American Science 7(6), p. 476
5) Adomian, G., 1988. Non-Linear Stochastic System Theory and Application to
Physics, Kluwer Academic Publisher, Dordrecht
17
18