Professional Documents
Culture Documents
Battery Charger
Battery Charger
battery
chargers
electric
Switching battery
chargers
Order code
Rated
output
current
Rated
output
voltage
DC
Qty
per
pkg
Wt
[A]
[V]
[kg]
0.270
0.270
1 charging level.
BCF 0250 12
2.5
BCF 0450 12
4.5
12
BCF 0125 24
1.25
BCF 0250 24
2.5
24
0.270
0.270
U
Uc
BCF...
General characteristics
Protections:
Mains input fuse
Electronic lock in case of short circuit on battery
terminals, battery polarity inversion, low voltage across
battery poles (<0.5 Ue) and disconnected battery
Relay alarm output.
LED indications:
Correct output voltage
Battery polarity inverted.
Operational characteristics
Auxiliary supply voltage: 100...240VAC (10%)
50/60Hz (5%)
Charging cycle: in accordance with DIN 41773 standards
Current limitation
Degree of protection: IP20
Fixed clamping screw terminal block with captive screws.
Type
0,5Uc
Ic
Maximum power
consumption dissipation
Mains
fuse
[VA]
[W]
[A]
BCF 0250 12
96
40
BCF 0450 12
181
76
BCF 0125 24
96
39
BCF 0250 24
181
72
Alarms
GREEN LED RED LED
RELAY
Correct output
voltage
ON
OFF
ON
Polarity
inverted
ON
ON
ON
Short circuit
OFF
OFF
OFF
electric
Linear battery
chargers
Order code
Rated
output
current
Rated
output
voltage
DC
Qty
per
pkg
Wt
[A]
[V]
[kg]
1.900
12
4.750
8.600
1 charging level.
31 BCE 0312
31 BCE 0612
31 BCE 1212
12
31 BCE 2V524
2.5
31 BCE 0524
31 BCE 1024
10
24
1.900
4.925
9.550
31 BCE 0312
31 BCE 2V524
Uc
a
0,5Uc
Ic
General characteristics
Protections:
Mains input fuse (except for BCE 2V5 and BCE 03)
Battery output fuse
Electronic lock in case of short circuit on battery
terminals, battery polarity inversion, low voltage across
battery poles (<0.5 Ue) and disconnected battery
Alarm output:
Negative static, NPN transistor for BCE 2V5 and BCE 03
Relay for BCE 05, BCE 06, BCE 10 and BCE 12.
Indications:
Power on
Charge (I > 0.2 Ic)
Alarm for protection tripping.
Operational characteristics
Auxiliary supply voltage: 220-240VAC 10%,
50/60Hz 5%
Charging current: 30-100% Ie adjustable
Charging cycle: in accordance with DIN 41773 standards
Current limitation
Degree of protection: IP00
Clamping screw terminal block with captive screws:
Removable for BCE 03 and BCE 2V5
Fixed for BCE 05, BCE 06, BCE 10 and BCE 12.
Type
DERATING CURVES
BCE 2V5 - BCE 03
DERATING CURVE
31 BCE 0612
31 BCE 0524
Charging current
100%
95%
240
V
AC
230
V
AC
220
VA
C
90%
75%
50C
55C
60C
65C
70C
Operating temperature
BCE 05 - BCE 06
DERATING CURVE
Charging current
100%
95%
240
V
AC
230
VA
C
220
VA
C
90%
85%
80%
75%
50C
55C
60C
65C
70C
Operating temperature
[W]
[A]
[A]
117
24
6.3
BCE 0612
222
46
12.5
BCE 1212
400
73
6.3
25
BCE 2V524
166
26
6.3
BCE 0524
317
40
12.5
BCE 1024
610
66
6.3
25
DERATING CURVE
100%
95%
230
VA
C
90%
Alarms
BCE 2V524 - BCE 0312
These types have a static alarm output for the control of a
relay or indicator, maximum 300mA duty.
If it is connected to a relay, this must be normally
energised in absence of alarm. In alarm conditions with
ALARM LED switched on, or in absence of supply, the
relay de-energises.
BCE 0524 - BCE 0612 - BCE 1024 - BCE 1212
These types have a normally energised relay alarm
output.
In alarm conditions with ALARM LED switched on, or in
absence of supply, the relay de-energises.
Possible causes of alarm include:
Low battery voltage
Battery fuse blown
Battery not connected
Battery polarity inverted.
Alarm output circuit
BCE 2V524 - BCE 0312
Type of output:
Negative static; NPN transistor
Maximum voltage applicable to load: +V battery
terminal
Maximum output current: 300mA
Maximum overload current for 1 second: 2A
Dynamic over-voltage protection with inductive load.
BCE 10 - BCE 12
Charging current
[VA]
BCE 0312
85%
80%
31 BCE 1212
31 BCE 1024
Maximum power
Mains Output
consumption dissipation fuse fuse
220
VA
C
240
VA
C
85%
80%
75%
50C
55C
60C
Operating temperature
65C
70C
electric
BCF...
50.6
44
5.6
96
90
45
91
Dimensions [mm]
100
POWER ON
CHARGE
ALARM
80
90
40
BATTERY
ALARM
OUT
BATTERY
FUSE
100%
30%
POWER
220-240V
65
93
70
100
60
50
120.5
140
POWER ON
CHARGE
80
90
100%
BATTERY
FUSE
BATTERY
-
ALARM
OUT
POWER
220-240V
POWER
FUSE
30%
COM NO NC
80
70
130
ALARM
60
50
40
178
POWER ON
CHARGE
ALARM
60
70
80
50
90
40
BATTERY
-
ALARM
OUT
POWER
220-240V
FUSE
POWER
COM NO NC
BATTERY
FUSE
100%
30%
178
Wiring diagrams
BCF...
BCE...
100...240VAC
L N
OUTPUT
RDY RDY
13.6...27.2VDC
230
140
180
192
electric
Technical
characteristics
TYPE
Description
Supply voltage
BCF...
BCE...
2.5-4.5A (12VDC)
1.25-2.5A (24VDC)
3-6-12A (12VDC)
2.5-5-10A (24VDC)
CHARGING CYCLE
Reference standards
Diagram
DIN 41773
U
b
Uc
a
0,5Uc
Current limit
PROTECTIONS
Mains supply fuse
Mains supply fuse
Charging inhibition due to:
(5, 6, 10, 12A types only)
short circuit at battery terminals
Battery output fuse
battery polarity inverted
Charging inhibition due to:
low voltage at battery poles (<0.5 Ue) short circuit at battery terminals
disconnected battery
battery polarity inverted
low voltage at battery poles (<0.5 Ue)
disconnected battery
ALARM OUTPUT CIRCUIT
1 output relay
3A 250VAC (AC1)
AMBIENT CONDITIONS
Operating temperature
-25...+51C
-10...+50C
Storage temperature
-25...+85C
-30...+80C
Modular
Open frame
HOUSING
Version
Degree of protection
IP20
Cooling
Connections
For 2.5A and 3A types only.
For 5, 6, 10 and 12A types only.
IP00
Natural
Fixed terminals
Removable/plug-in terminals
Fixed terminals
Planet Switch
OFF
ON
Switch disconnectors
Contactors
Motor protection relays
Electromechanical starters
Control and signalling units
Limit , micro and foot switches
Rotary cam switches
7)
13(
5
3
1
.10
1
A1
2
24V
Hz
13
14
Modular contactors
(7)
(8)
A2
lar
Modu
Planet Din
The products described in this publication are subject to be revised or improved at any moment. Catalogue descriptions and
details, such as technical and operational data, drawings, diagrams and instructions, etc., do not have any contractual value.
In addition, products should be installed and used by qualified personnel and in compliance with the regulations in force for
electrical systems in order to avoid damages and safety hazards.
CN25
50/60
ctor
conta
Time relays
Protection relays
Level control relays
R1
0,
0,
T
R
G
A
K
LE
LH
R
EA
O
oreest
au
t(sec
T
SE
In0,x
tx1
Inx
In1x
RE
reesn
ma
tx
2,
In(A
ST
TE
0,
0,
0,
0,0
0,0
I
TR
1,
1
0,
0,2
reesn
ma
tx
T
C
OIN
FU
oreest
au
In0,x
In1x
In1x
tx
oreest
au
tx1
Inx
reesn
ma
L
A
C
IE
nT
N
IS
In0,x
tx1
Inx
reesn
ma
Inx
In1x
tx
oreest
au
In0,x
tx1
Inx
In0,x
In1x
Fuse holders
RUN
MON
STOP
ENT
AC motor drives
Automatic power factor controllers
D
RGE
Y CHA
TER
BAT
ATIC ER ON
OM POW
AUT
RGE
CHA
ALAR
LW
Y
R
O
G
E
BTA
V
LO
W
S
LY
R
E
T
U
BO
F
BA
T
Y
O
N
C
TR
NE
C
BA
IL
V
R
Y
TO
E
T
IN
PA
BA
BC
7
6
8
9
BATTERY
FUSE 6,3A
100
-3V=
12
LINE
5-2.V=
24
LI
M
H
T
S
N
FA
W
C
L
IO
R
SE
T
C
AU
AT
AU
MA
O
OF
OF
E
S
RE
O
W
A
R
D
TH
WI
I
TR
O
OF
O
W
U
AE
T
E
O
R
7.D
P
T
O
LO
N
A0
A
LO
I
TR
W
A
R
D
TH
WI
S
TE
LINE
L
RGE
ALARM OUT
I CHA
BATTERY
30
AR
AL
S
TE
POWER
220-240V~
50-60Hz
Planet Logic
Soft starters
E
N
R
T
D
A
G
R
N8O
A0
E
G
Y
C
M
R
N
T
E9O
S
A0
E
LHI
W
U
A
LT
N
2S
FI4C
A0
NR
A
O
G
H
S
Q
PI5E
LS
N
1W
A0
NR
O
G
A
H
S
Q
LI6E
N
2W
P
S
A0
LW
Y
R
G
E
1A
O
LT
B
V
A0
LH
IY
R
O
G
A
H2TE
G
B
V
A0
E
H
LI
W
U
A
T
LI3C
N
1S
F
A0
LINE
I
M
L
S
N
A
H
FT
W
O
IL
E
C
SR
T
C
AU
AT
S
TE
LINE
L
AU
MA
O
OF
O
W
A
R
D
TH
WI
I
TR
OF
E
S
RE
O
OF
O
W
A
R
D
TH
WI
U
T
W
AE
E
O
R
7.D
T
O
N
P
LO
A0
A
LO
I
TR
E
N
R
T
D
A
G8O
N
R
A0
E
G
Y
TC
M
R
N
S
E9O
A0
E
LHI
W
U
C
2S
TI4A
LF
N
A0
NR
A
O
G
H
S
Q
PI5E
LS
N
1W
A0
NR
O
G
A
H
S
Q
LI6E
N
2W
P
S
A0
LW
Y
G
R
A
1E
O
LT
B
V
A0
ILH
Y
G
R
O
A
2E
HT
G
B
V
A0
LH
EI
U
W
C
F
T
L1SI3A
N
A0
www.LovatoElectric.com
LOVATO ELECTRIC S.P.A.
CONTROL SOLUTIONS FOR INDUSTRY
Germany
Spain
Poland
Czech Republic
USA
Canada
Mexico
LOVATO S.R.O.
Tel. +420 382 265482
www.Lovato.cz
LOVATO ELECTRIC
CORPORATION
Tel. +1 450 681 9200
www.Lovato.ca
LOVATO ELECTRIC
DE MEXICO, S.A. DE C.V.
Tel. +52 555 3415662
www.LovatoElectric.com.mx
PD68 GB 01 11