You are on page 1of 2

QUI TRNH THAY DRUM GT T- ROLLS

(Dnh cho bizhub 283/363/423)


-

Tt ngun my

V sinh my v thay drum, gt, t, rolls mi vo my.

Thay vt t xong, M CA BN PHI MY RA, m cng tc ngun (mc ch m ca


bn tay phi ca my khi m ngun th my bo h ca nn khng bm mc xung hp t
c).

Vo Service mode Counter Life


+ Xa Drum unit rotation time.
+ Xa Developing unit rotation time.
(Bm chn mc cn xa v bm phm C trn bn phm xa, xa xong bm [End]
quay v menu chnh ca Service mode).

T Service mode, chn Imaging process adjustment


+ Chn Max Image Density Adj = 0 (a v 0)
+ Chn TCR Level Setting = 0
+ Chn TCR Sensor Adjust, chn Black, NG CA BN PHI MY LI, bm phm
[START] trn bn phm chy t (phm START chuyn mu cam, khong 1 pht sau xong
th phm START chuyn sang mu xanh, bm [End] kt thc).

Kt thc bc chy t
KONICA MINOLTA

Trang 1

Chnh cht lng hnh nh


(Thc hin bc ny khi thay drum, gt, t hoc khi m bn chp khng u).
-

V sinh gng t bn gc tht sch v np giy A3 vo khay giy.

Vo Service mode, chn Imaging process adjustment, chn Gradation adjust, chn
Initialization, bm START.

Sau chn Max Density Adjust, chn giy A3, bm START in ra bn test. t bn test
ln gng, bm START my qut bn test vo (cn chnh t ng).

Sau khi chy xong Max density adjustment, chn Gradation adjustment, chn giy A3,
bm START in ra bn test, t bn test ln gng, bm START c bn test (cn
chnh). Lm tng t thm 2 ln na (tng cng 3 bn test c in ra v qut vo my 3 ln).

Lu : Sau khi thc hin y cc bc trn, nu bn chp hi m hay hi m th chnh D Max


Density bng tay nh sau: Vo Service mode Imaging process adjustment Max Image Density
Adj, chn Black v thay i gi tr. Tng (+) th m, gim (-) th m.

Kt thc
KONICA MINOLTA

Trang 2