N=
EA
(0.85)
(110)(25.60)
(1800)(0.85) = 1.84 or 2 CFL @ 26 W
Bedroom 1:
Area: 3.9 x 5.0 = 19.50m2
Type of lamp/s used: CFL @ 26 W
With =1800 lumens
Recommended illumination: 110lux
Applying Area Method:
N=
N=
EA
(0.85)
(110)(19.50)
(2900)(0.85) = 1.40 or 2 CFL @ 26 W
Bedroom 2:
Area: 3.9 x 4.9 = 19.11m2
Type of lamp/s used: CFL @ 26 W
With =1800 lumens
Recommended illumination: 110lux
Applying Area Method:
N=
N=
EA
(0.85)
(110)(19.11)
(1800)(0.85) = 1.37 or 2 CFL @ 26 W
Dining Area:
Area: 3.5 x 3.10 = 10.85m2
Type of lamp/s used: T8 Fluorescent Lamp @ 78 W
With =4000 lumens
Recommended illumination: 540lux
Applying Area Method:
N=
N=
EA
(.7)(0.85)
(540)(10.85)
( 4000)(0.85) = 1.72 or 2 T8 Fluorescent Lamp @ 78 W
Kitchen:
Area: 3.5 x 3.0 = 10.50m2
Type of lamp/s used: T8 Fluorescent Lamp @ 78 W
With =4000 lumens
Recommended illumination: 540lux
Applying Area Method:
N=
N=
EA
(0.85)
(540)(10.50)
( 4000)(0.85) = 1.67 or 2 T8 Fluorescent Lamp @ 78 W
Comfort Room:
Area: 1.9x 2.9 = 5.50m2
Type of lamp/s used: CFL @ 13 W
With =900 lumens
Recommended illumination: 110lux
Applying Area Method:
N=
N=
EA
(0.85)
(110)(5.50)
( 900)(0.85) = 0.79 or 1 CFL @ 13 W
Laundry Room:
Area: 4.9 x 1.4 = 6.86m2
Type of lamp/s used: CFL @ 36 W
With =2900 lumens
Recommended illumination: 320lux
Applying Area Method:
N=
N=
EA
(0.85)
(320)(6.86)
(2900)(0.85) = 0.89 or 1 CFL @ 36 W