Professional Documents
Culture Documents
HAND BOOK
OF MECHANICAL MAINTENANCE
Prepared by : E. Jayaprakash
S. Jawahar
K.G. Panicker, TS
Approved by : S. Krishnamurthy, CS
Rev: 0
January`2004
2
PREFACE
We are grateful to all those who gave their valuable suggestion for
making this work, we are also grateful to all those persons to whom it is
not possible to acknowledge here individually due to paucity of space,
from whom help is taken in making this book.
3
CONTENTS
1. Pumps 6
5. Piping 29
7. Heat Exchangers 37
8. Compressor 42
9. Diesel Engine 47
11. Refrigeration 58
12. Turbine 62
4
PART-B - MECHANICAL GENERAL
3. Material Handling 71
4. Hydraulics 76
5. Engineering Metals 83
7. Hardness Testing 89
8. Mechanical Fasteners 90
11. Sealants 96
12. Welding 97
5
TABLES
_____________________________________________
Sl.No Contents Page No.
1. Compatibility And Pressure Temperature 106
Rating Of Commonly Used Gaskets and
Elastomers
2. Gasket Pressure Temperature Limits 107
3. Recommended Gasket Compression For 107
Spiral Wound Metallic Gasket
4. Minimum Gasket Seating Stress 108
5. Torque Required To Produce Bolt Stress 109
6. Data For Use With Alloy Steel Stud Bolts 110
7. Nut Factor 111
8. Gasket Factor (M) For Operating Conditions 112
9. Nomenclature Of Mesh 113
10. Wire & Sheet Metal Gauges 114
11. Threading Taps 115
12. Standard Stainless Steels Composition (%) 116
13. Elastomers and their properties 117
14. Lubricant minimum viscosity 118
15. Viscosity conversion tables 119
16. Refrigerant P-T chart 121
17. Humidity chart 122
18 Vibration severity charts 123
19. Forged flanges table 125
20. Hardness conversion table 126
21. References 127
6
Part-A – Mechanical Equipments
1. Pumps
v Net Positive Suction Head is the gauge pressure at pump suction minus the gauge
vapour pressure of liquid corresponding to its temperature and velocity head at this
point.
NPSH available should be > NPSH required.
NPSH = HP - HVap + Hz - Hf
HP = Pressure of fluid in suction tank.
Hvap = Vapour pressure of fluid at pumping temperature.
+Hz = Positive suction head when the water level is above the pump centre lines.
- Hz = Suction lift when the water level is below the pump centre line.
Hf = Friction losses in piping.
v Cavitation: Bubbles are formed in the moving liquid at the eye of the impeller when
the pressure at any point falls less than the vapour pressure at the temperature. The
bubbles are collapsed at the high pressure region and causing damage to the pump
internals.
v Specific speed is the speed of an imaginary pump, identical with the given pump, which
will discharge one litre of water per second while it is being raised through a head of one
metre.
N√ Q Where N = Speed of the impeller in rps
Ns = ----------- Q = Discharge of the pump in M3/Sec.
H3/4 H = Head, against which the pump has to work.
v Location of Impeller:
a) Double suction impeller in the horizontal pump to be locked at the centre of total end
ply.
b) In Single inlet impeller shaft to be locked with 1/3 of the total end ply movement from
suction side.
v Wearing ring:
a) Wearing ring clearance- 0.025 to 0.0375 mm (1to1.5 thou/inch.φ).and should not be
more than 0.075 mm (3 thou/inch.φ).
7
b) Wearing ring clearance={0.25+(D-150) 0.001mm.)(D=Inner dia.of wearing ring in
mm).
c) A general rule is to replace the wearing ring when the clearance has increased 100%
above the original
v Priming:
a) Never attempt to prime a centrifugal pump while it is running.
b) Pressure developed by the impeller of a Centrifugal pump is proportional to the density
of the fluid. Therefore it will produce only a negligible pressure, if running in air, which
may not suck water.
c) The specific weight of air is approximately 1/800 that of water. A centrifugal pump can
produce only 1/800 of its rated liquid pressure. For every 1 meter, water has to be
raised to prime a pump, the pump must produce a discharge head of air of
approximately 800 meter. It is therefore apparent that the head required for a
conventional Centrifugal pump to be self-priming and to lift a large column of water
when pumping air is considerably greater than the rating of the pump.
v Direction of Rotation:
a) Impeller rotates in the direction away from the vane curvature and always towards
the discharge nozzle.
b) Newly installed motor, direction of rotation to be checked before coupling. This is
particularly important on vertical pumps to avoid unscrewing of shaft coupling.
v Stuffing Box:
a) Gland Leak--10 to 12 drops/minute (For Lubrication of packing)
b) Adjust the sealing liquid flow 3.8 to 7.6 litres/minute (usually sufficient) to ensure
packing lubrication.
c) Examine the gland follower for general condition and fit. The inner radial clearance
should be 0.4mm (0.015”) maximum and the outer radial clearance should be 0.25mm
(0.010”) maximum to prevent the risk of cocking or touching on the shaft.
d) An average, gland packed shaft/sleeve needs replacement at least once in every year.
e) It is estimated that the energy lost due to gland friction is usually upto 10% of the output
of the motor, whereas the mechanical seal consumes negligible power.
v Progressing cavity pump: The principle of a rotor (Similar to a single start thread)
turning inside a stator (Similar to a twin start thread of the same profile) – produces a
flow directly related to rpm and by the diameter of the rotor. The series of `moving
Cavities’ formed as a rotor (a larger rotor produces larger cavities increasing the
8
capacity) per revolutions turns inside the stator produces a pumping action that
required no valves and is therefore particularly suitable for pumping viscous, highly
particulate, abrasive or fragile structured products.
The valve less PCP ensures pulse-free delivery
v Turbine Pump:
a) This pump has some Characteristics of both Centrifugal and positive displacement
pump.
b) Pressurise depends on momentum given to liquid by spinning rotor.
c) Overall efficiency is about 40 to 50%, but design simplicity overcomes the efficiency.
v Double suction reduces the axial thrust of impeller & Double volute casing reduces the
radial thrust on impeller.
v Slip: (a) In practice, the actual discharge is less than the theoretical discharge.
Difference between these two is known as slip of the pump.
(b)Slip is the loss in capacity through clearance between the casing and the rotating
element and capacity varies as the discharge pressure increases.
v Generally the suction line is larger than the pump discharge nozzle and for horizontal
pump eccentric reducers should be used.
a) If the source of supply is below the pump centre line, the reducer should be
installed straight side up.
b) If the source of supply is above the pump, the straight side of the reducer should be
at the bottom.
c) Installing eccentric reducers with a change in diameters greater than10 cm (4 inch.)
could disturb the suction flow.
v Piping Strains:
9
Cast Iron pumps are never provided with raised face flanges. If Steel suction and
discharge piping is used, the pipe flanges should be of the flat face and not the raised
face type. Full-face gaskets must be used with cast iron pumps.
v Following are the varies cases, when lantern ring & sealing liquid are used :
a) A suction in excess of 5 meters.
b) A discharge pressure less than 7 meters.
c) Hot water (over1200c) being handled without adequate cooling.
d) Muddy sandy or gritty water being handled.
e) The liquid being handled is other than water such as acid, juice or sticky liquids.
v There is no clear-cut distinction between flat head & rising head characteristics.
However as a rule of thumb, curves that shows a 150% increase in head from the
capacities of peak efficiency & shut off are called “steep rising” curve; those showing a
10
10 to 25% rise are called “steady rising” curves & those with no more than 10%
increase are called “flat”.
v 1 ml is equal to 37 drops for servo mesh 257 oil, 39 drops for servo system 68- oil.
11
2. Seals & Packing
Gaskets
v WHY THE GASKET? Most flat faces, which appears flat enough to the naked eye,
would on microscopic examination reveal irregularities on the surface with crests and
valleys.
v Selection of a Gasket: The factors to be considered for the selection of Gaskets are:
1. Compatibility of the Gasket material with the fluid.
2. Pressure and Temperature conditions of the System.
3. The relationship of total installation bolt force to gasket seating stresses and hydrostatic
end force.
v Y Factor: When High Gasket Seating stress is achieved at assembly, better sealing
performance is achieved. This is the `Y’ factor.
Gasket Seating Load
Gasket Seating Stress Y (PSI) = ---------------------
Gasket Seating Area
v M Factor: The Gasket factor (or) Maintenance factor at operating condition is the ratio
between the Residual Gasket Seating stresses to the internal pressure.
Gasket Seating Stress Y
`M’ Factor = ----------------------- = -----
Internal Pressure P
v Test has shown that maximum Lip Seal life is obtained when the shaft sealing surface is
8 to 20 inches in roughness. If the shaft is too smooth, it will not support a film. If too
rough, it wears the seal lip.
a) Radial lip seals (Dynamic and Static) are primarily used to retain lubricants and exclude
contamination.
b) The Seal functions at temperatures from 15oC-205oC.
12
c) Advantages of lip seals are low cost, small space requirements and simple
installation.
d) Lip seals recommended only for non pressure service and perform best in good
lubricating media.
e) Lip will have narrow contact area about 1/16” (1.6mm) wide which, under pressure,
causes extreme local heating and wear.
f) Materials of lip seals are acrylates (-29 to 149oC), nitriles (-54 to 107oC), fluro
elastomers (-40 to 204oC), Silicon (-60 to 77oC) and TEF Fluoro carbons (-84 to
204oC).
g) Lip type seal is quite sealing upto 3000 hrs.
Labyrinth Seal
a) Labyrinth seals are used mainly in high-speed applications where relatively high leakage
rate can be tolerated and simplicity is necessary.
b) It does not require lubrication or maintenance.
c) Leakage flow through inclined, stepped labyrinth is about 40% that of straight labyrinth
for similar conditions.
d) Labyrinth Seal (high quality bronze) designed for 1, 00,000 hrs. equals to 11.4 years
of continuous operation.
Felt
v It consists of fibers-wool and used as sealing material for the following reasons:
a) A very common seal for low shaft speed limit if only 610 mtr. per min. (2000 fpm). It
scans satisfactorily seal upto 1210 mtr. per min. (4000 fpm) where shafts are hard
smooth finish and where ample lubricants is present.
b) Oil storage capacity is largely a function of density and about 78% of the volume of a felt
seal serves as oil storage.
c) In dry state it filters 99 to 100% of 0.7 microns size particles. When saturated in
lubricants, even smaller particles are trapped and retained
d) Maintain constant sealing pressure and offer low friction.
e) The usual temperature limits of felt are -51 to 121oC synthetic fiber felts can withstand
upto 204oC.
`O’ Ring
a) The nominal pressure limit for `O’ rings, based on typical mechanical clearance is 1500
Psi (105Kg/cm2) and with backup ranges 3000 Psi (210Kg/cm2).
b) Elastomers ensure elasticity and return of the material to its original shape when a load is
removed. This property is known as resilience.
c) ‘O’ ring softer compounds provide better sealing ability as the rubber flows more easily
into the groove. Descending order of the `O’ ring material is to be considered as more
softness - Natural rubber, Nitrile, Viton, and Silicon etc.
d) Harder compounds are specified for high pressure, to limit chance of extruding into the
groove, and to improve wear life for dynamic service. Similar consideration is given to
the temperature applications.
e) Shore A hardness from 50-70 are the most suitable for most `O’ ring application.
f) `O’ ring materials have a Co-efficient of thermal expansion 10 times greater than that of
Steel. (I.e. Nitrile CTE is 6.2 * 10-5/oF and Steel CTE is 7.0 * 10-6/oF).
13
v `O’ Ring installation and design:
a) The Volume of the seal housing should be approx. 25% greater than that of the
corresponding `O’ ring to compensate for the high degree of thermal expansion or possible
swelling of the elastomer.
Static seals: The lubricant is only necessary to aid in assembly. When applying lubricant to
stationary seals a very thin film is all that is needed. You should not even see the lubricant
on the surface except for the polish it gives to the O-ring. Remember, in some cases a little
water is an adequate lubricant. Use this to judge how much lubricant to apply.
Sliding Seals: Sliding seals require more lubricant than static seals, but not much more.
Rather than a film, sliding seals require a thin coating.
14
Dry Lubricants: Sufficient lubricant should be applied to give a dull gray finish to the
surface after the carrier has evaporated.
15
Mechanical Seal
v The run out of the shaft/shaft sleeve (i.e.) shaft deflection and shaft whip should be
limited to 0.05mm max.
v In mechanical seal, the seal faces are right angle to the shaft centre line, therefore in
conventional language; this is called as end face mechanical seal.
v Sealing surface flatness and finish are important factors for mechanical seals to reduce
leakage and wear of seal faces. Surface flatness is to be below three light bands (less
than 40 µinch) and surface finish is to be less than 5 micro inch rms.
v Make sure that the seal seat is perpendicular to a shaft within 0.001 inch TIR.
(TIR is total change in indicator reading).
v Replace bearing if end play exceeds 0.05mm (0.002”) or radial looseness is greater
than 0.1 mm (0.004”).
v Replace the shaft with a new one if run out exceeds 0.05 mm (0.002 inch) TIR.
v Corrosion
Selection of the material of mechanical seal parts based on the fluid being handled. The
fluid is classified into two categories viz. Corrosive and Non-Corrosive with respect to
SS 316. Here the criteria of classification are based on the corrosion rate of less than
0.05 mm (2 mils) per year.
When the corrosion rate is greater than 0.05mm per year, double seals that keep the
hardware items of the Seal in a neutral liquid should be selected to reduce corrosion.
Stationary seal, which is exposed to the corrosive liquid, should be constructed of
corrosion - resistant materials such as Ceramic, Carbon and Teflon.
v PV Factor: It is the product of seal face pressure and a linear rubbing velocity of a
mechanical seal. The seal face pressure is calculated using the formula:
Pface = PBox * Balance Ratio and
PV = Pface * V (Kg/cm2 * m/sec.)
Higher the PV value of seal pair will give a longer seal life.
16
Carbon Tungsten Carbide 1000000 350
Carbon Ni-Resist 850000 300
Tungsten Carbide Silicon Carbide 500000 170
Balancing ratio is the ratio of mating area of both rings above the balancing line to the
total mating area of both rings. It can also be defined as the ratio of closing area to the
opening area.
OD2 - BD2 | Where OD = Seal face outside diameter,
Balance Ratio = ------------- | ID = Seal face inside diameter&
OD2 - ID2 | BD = Balance diameter of the seal
v Rotating seal compression head is upto 5000 ft. /min (5.4m/s), more than this,
compression head is in stationary.
v Normally, the flat seal rings have different hardness values and the soft one is lower
then the hard one.
v Unbalanced Seal design (more closing force) is for low pressure application and its
balance Ratio is 1.25 to 1.35
v Fully Balanced Seal (Floating condition) closing force and opening force are equal.
Hence balancing ratio is 0.5.
v To ensure that the seal faces are always positively loaded, balance ratio of a mechanical
seal must be above 0.56, in practice is normally kept at 0.7 to the balanced seals.
MAPS PHT circulating pump seal’s balancing ratio is 0.65.
17
Difference between them is that the double seal has a pressurised barrier fluid and
tandem seal (Secondary seal serves as backup to primary) has non-pressurised barrier
fluid.
18
Packings
v Packing failure: Approximately 70% of packing failures result from human errors (i.e)
Unsuitable material selection, improper fittings, neglecting to test reassembled valve etc.
v Compression packings are used to throttle leakage between a sliding, moving or rotating
parts and a stationary one.
v Therefore Compression packing creates a seal, when squeezed, the packing flows
outward to seal against the bore of the box and inward against the moving shaft/stem.
v Cotton grease lubricated packing to be used for Low temperature 93oC (200oF) and
Low speed pumps.
v Asbestos graphite/Mica coated for High temperature and high speed pumps.
v Selection of packing depends on shaft size, material and hardness, shaft speed, pressure
and temperature on the stuffing box and PH of the fluid to be sealed.
v Pump shaft TIR at gland location should be within 0.05 mm and should have smooth
finish.
v Gland loading has to be done while the pump is in operation. Otherwise it may result in
Excess loading and lead to burning of packing after starting.
19
3. Power Transmission Components
• Square Keys:
a) If a Square key and the shaft were to be of the same material and of equal strength, the
length of the key would be 1.23 times the dia. of shaft.
b) Parallel (non prestressed) keys are made Square (width = height) upto width = 38 mm
(1½ inch), the width = ¼ Dia. of Shaft. For larger key width, the key height is usually
smaller than width.
c) The depth of the key way in the shaft and in the hub usually is equal to ½ height of the
key.
• Rectangular Keys:
a) If a rectangular key and a shaft are made from the same material, for equal strength, the
size of the key in general will be width of D/4 and a height of 3D/16 and length of 1.57D.
b) As per IS 2048 Depth of key way is 60% and 40% in the shaft and hub respectively.
c) As per IS 2710 the depth of key way is 70% and 30% in the shaft and hub respectively.
d) Key to hub top clearance is 0.2 to 0.5mm for key thickness of 2mm to 50mm thick.
v Splined Shaft
a) Compared with keys, splines have the advantages of self centering.
b) For a given torque transmission, a splined shaft is less weakened than keyed shaft.
Thus it can transmit higher torque.
`V’ BELT
v General:
a) Generally less than 186.5 KW (250 HP) and for low speed application.
b) ‘V’ belt drive has transmission loss about 5% and as such the prime mover has to
cater for the same.
c) ‘V’ Belt generally for short distance and medium torque transmission.
Nominal dimensions of Standard `V’ belts
20
e) The standard angle between the sides of a `V’ belt is 40o.
f) Belt life at temperature above 82ºC (180ºF) and below (51ºC) –60ºF is signification
shortened.
v Slip in belt drive is difference between the linear speed of the rim of pulley and the belt
on it.
21
v Belt tension check: A belt that is too loose will slip and cause heating and wear. A
belt that is too tight may overload the bearings, leads to misalignment and can consume
extra horse power.
a) With moderate thumb pressure i.e., 1 kgf applied to a belt at mid point between
unsupported 1220 mm (48 ") length the deflection should be equal to its own
thickness or Deflection 0.4 mm per 25 mm (1/64" per inch) span.
b) This method requires experience in getting the proper feel. Slap the belt sharply with
the hand. A properly tensioned belt will feel springy and alive. If the belts were too
tight or too loose it would not spring.
c) A quick check to determine if belt adjustment is proper may be made by observing
the slack side of the belt for a slight bow when the unit is in operation.
d) Deflection -16mm per metre of Centre Distance Force at the centre of the belt
should be given as follows
`V’ Belt Section A B C D E
Kilogram
(Kgf) force 1.0 to 2.0 to 3.1 4.1 to 6.1 7.1 to 10.7 12.2 to 18.3
required at centre 1.5
v Pulley:
a) Angle of belt contact on small pulley should have
a) 150o for flat belt drives, b) 120o for ‘V’ belt drives
b) Shaft axis out of parallelism should not be more than 0.5 mm / 100 mm run.
c) Pulley off set should not be more than 1 to 2 mm per meter.
d) Limit of cast Iron pulleys max. speed in rpm corresponding to 6500 fpm. (33m/s).
e) Maximum efficiency is obtained at speed between 20 and 25m/sec.
f) Pulley’s groove surface roughness Ra = 1.6µ for peripheral speeds upto 10m/sec.
and Ra = 0.8µ for peripheral speeds over 10m/sec.
v Due to increased bending and windage losses combined with the loss due to wedging
action, the efficiency of drive is about 3% lower than that for flat drives.
22
h) If the center distance between the pulleys is more than 6 feet, use the straight edge /a taut
wire or cord.
v Foundation:
Thumb rule of Concrete weight is equal to three times of the machine weight for rotating
machine and five times for reciprocating machine.
Coupling Alignment
v Causes of Misalignment:
a) Soft foot (Leveling of foundation base) short or long leg of machine.
b) Corrosion and Erosion of Foundation
c) Pipe strain – Forces transmitted to the machine by pipe or support structure.
d) Thermal Expansion – Most machines aligned in cold
e) Machine vibration
f) Direct coupled machines are not properly aligned.
g) Poor workmanship.
v Effect of Misalignment:
a) Most experts agree that 50% of Machinary problems are caused by misalignment.
b) Increases 2-17% power consumption.
c) Causes vibration, which destroys the critical parts such as bearings, seals, gears,
couplings etc.
v Recognition of Misalignment:
a) Excessive radial and axial vibration
b) Repetitive/Premature of bearing, seal, shaft and coupling elements.
c) High casing temperature at or near the bearing or high discharge oil temperature.
d) The Coupling is hot while running and soon after the Shutdown.
23
b) Difference in outside Diameters (OD) of the coupling halves
c) Checking `Bracket Sag’: Whenever every mechanical brackets and dial indicators are
used to measure shaft positions, `bracket or bar’ sag must be measured and
compensated for.
Radial Reading
Radial Misalignment = ----------------
2
Face dial Reading
Angular Misalignment = -----------------------------
Distance traveled by the dial
v Advantages & Disadvantages
a) Can be used where one of the shafts cannot be rotated during alignment.
b) Difficult to obtain accurate face readings if motor has axial float.
24
v Hot Alignment
a) One way of achieving hot alignment is to premisalign by providing a calculated
misalignment between motor and fan in the cold condition.
b) As a thumb rule, the thermal expansion of a Pedestal shall be approximately
1.0mm/1 meter/100oC rise.
25
4, Bearings and Lubrication
Bearings
v Replace all bearings and running joints whose clearance has increased more than 100
percent of the original.
v Bearing Fit:
a) Ring which rotate must have interference fit with shaft /housing.
b) SKF’s recommendation for press fits is a minimum 80% metal-to-metal contact
between mating parts for existing applications. New OEM (Original Equipment
Manufacture) fits should have 95% metal-to-metal contacts.
v The inner and outer rings of rolling contact bearings are hardened (Rockwell C 60 to
65) Carbon Chromium steel (SAE 52100). The composition is carbon 1%, Chromium
1.5%, Iron 87%, Manganese 0.35%, Silica 0.3%, Phosphorus and Sulfur 0.025%
each.
v Bearing Life: The life of a bearing is generally expressed in millions of revolutions. Life
of ball/roller bearing (L) is inversely proportional to the K power of the radial load (F).
i.e. L α 1/F k. For ball bearings the value of constant K is 3 and for roller bearings it is
taken is 3.33.
v Minimum load required for bearing is Fm=0.02*C to avoid vibration because rolling
action. Where C = Basic Dynamic Load Rating.
v Bearing failure:
Improper lubrication - 43%, Improper mounting - 27%
26
a) Contamination is also a leading cause of premature bearing failure. Hence
relubrication, proper mounting and sealing are the critical actions to ensure that the
bearing does not fail prematurely.
b) The grain structure changes, when the temperature exceeds 1200 C and hence
hardness also changes. Loss of 2-4% hardness reduces the bearing life by
50%. Hardness of outer and inner ring is 54 to 59 HRC, and rolling element is 59 to
64 HRC.
c) Storage and handling: Bearing can be stored in their original packages for years
provided relative humidity in the storeroom does not exceed 60% and there are no
great fluctuations in temperature.
v Bearing Mounting:
• More than 60 mm bearing required temperature mounting
• Oil bath heating is not advisable because
a) Contaminated oil.
b) Oil flashes risk is involved.
c) Should use new oil all the time.
d) Flash point of oil should have more than 200’c
• Induction heater:
a) Temperature mode: - cut off at 110’c and demagnetize with in 5 sec.
b) Time mode: - cut off at 60 min.
v The raceways are accurately ground in the rings to a very fine finish (16µ inch or less).
v Ball bearings function on point contact. Thus suited for higher speeds and lighter loads
than roller bearing.
v Roller bearings function on line contact. They take heavy loads including shock, but are
at lower speed.
v Doubling the misalignment force reduce the lifetime to 1/8th, three times the force reduce
the lifetime to 1/27th of the original lifetime.
v Preload- thump rule- rotate by ¼ turns loose after tight. Check by dial gauge also.
27
a) Because of the large track radius in the outer ring load carrying capacity is less than
single row rigid ball bearing and thrust load capacity is very small.
b) Self-aligning ball bearing can take misalignment up to 30 arcs from vertical centre
line.
c) The Self aligning feature should not be abused, as excessive misalignment or thrust load
(10% of radial) causes early failure.
v Needle Bearings:
a) The bearings have rollers whose length is at least 4 times their diameter.
b) They are most useful where space is a factor and are available with or without inner race.
v Compliant Bearing:
a) Greater load carrying capacity than equivalent rigid surface bearing.
b) Ability to tolerate misalignment, shaft bending, eccentricity, inadequate lubrication etc.
c) Elastically deform equal to or more than the lubricating film due to fluid pressure
induced in the film.
d) Tolerates sand and silt contamination without scoring the shaft.
e) A Continuous coolant flow of two gallons (9.1 litres) of water per minute per inch.
(25.4mm) of bearing is recommended as a rough working rule. The flow of cooling
water should restrict temperature rises to about 3oC (Maximum).
v The limiting speed of rolling element bearing in rpm, the oil lubricated bearings is 1.25
times higher and thrust bearings are 1.4 times higher than grease lubricated bearings.
28
v Large bearings are oil bath heated to 80 to 90oC above ambient temp, but should not
reach 120oC.
v Kingsbury thrust bearing can take both directional thrust load whereas Mitchel thrust
bearing can take one directional thrust load.
v Lead wire to measure the bearing clearance should not be more than 0.010” (0.25mm)
thicker than the estimated bearing clearance.
v When D is the diameter of the journal, the frictional horse power increases by D2.
Lubrication
v The first principle/right principle of lubrication is to put the right lubricant in the right
place at the right time.
v A little water (0.02%) in the bearing oil can reduce rated bearing life by as much
as 48%.
v Grease (servo gem 3, servo gem 2, LMM) lubrication bearings for normal speed and
low temp. application.
v Grease:
Calcium soap (Ca) - up to 60oC
Higher quality like calcium - lead soap upto 120oC
Sodium soap (Na) - higher temp.
Synthetic sodium grease - upto 150oC
Lithium soap (Li) - higher temp. range than sodium soap
Synthetic grease (ester, silicone)
Offer low frictional resistance at low temp. even - 70oC
29
v The upper and lower temp. limit for grease is approximately + 140oC and - 30oC.
(General purpose).
v The percentage of the oil in grease is usually about 80%, but can range from 70% to
97%.
v Grease consistency - means the degree of stiffness, which the grease possesses.
NLGI - National Lubricating Grease Institute. This is based on the degree of
penetration achieved by allowing a standard cone to sink into the grease of a
temperature of 25oC over a period of 5 seconds.
Subsequent measurement of the depth of penetration is at each 1/10 of mm.
v Quantity of grease is to be filled 2/3 volume of the left out volume inside the Plummer
block.
v Relubrication Guidelines:
a) Regreasing quantity in grams | where D = Outer diameter of the bearing
G = 0.005 D B | B = Width of the bearing
v When Relubricating with new grease, make sure the old and new grease are
compatible. If there is uncertainty, try removing all traces of the old lubricant
without using cleaning solvent.
v Oil life:
If operating temperature is with in 300 C- life is 30 years.
Every rise in 100C- life reduces to half.
30
60 to 700C -1 to 2 years.
1000C- only 3 months.
v Oil Quantity: For high speed at high temperature application regular feeding of small
amount oil is required. For moderate and low speed bearings oil level to be maintained
to the centre of the lowest ball or roller.
v SENSOR TESTS
APPEARANCE? Look at the oil in a clean, dry sample bottle. Clear and bright? Or
hazy and cloudy, indicting water contamination? Suspended material? Is it typical of
the product? Basically, how des it compare with the original?
COLOR? This is useful for light-colored lubricants. How does the lube compare with
the original? Dark? This could indicate oxidation, possibly at high temperatures.
ODOR? Compare carefully with the original. Oxidized oils and greases have “burned”
or pungent odors. The same is true of irradiated lubricants - Odors show up by 108
rads.
31
relative tests – you must have a sample of the original grease or oil with which to
compare the used product.
32
5. Piping
v As per ASTM (American Society for Testing and Material). Pipes are
distinguished based on weight of pipe is given as follows.
P (M ax.)
v Schedule No. = --------- * 1000
S (Max.)
33
Grade C - High Carbon Steel
v Standard size of pipes: (For C.S & S.S): Diameter of 12” and less has a nominal size
and wall thickness varies as per Schedule No.
v Over 12” is based on the actual outer diameter and wall thickness is specified.
v Mild steel (M.S) Pipe sizes are graded as Light, Medium and Heavy.
v The head loss due to pipe friction increases approximately as the square of the liquid
velocity in the pipe line. Hf1/Hf2 = (V1/V2)2
Where Hf1, Hf2 = Head loss due to the condition of 1 &2.
V1, V2 = Velocity of the fluid at condition 1 & 2.
v Double the flow increases the head loss four times in the pipe.
v Double the pipe size increases the internal area by four times.
v The Co-efficient of expansion for any grade of Iron or Steel is approximately 0.000007
inch. degree F/inch length. For example, if the temperature of a steel pipe is raised by
400oF, its length will increase by about (400 x 7 = 2800) 0.28 inch/100 inch. length.
v Pipe Bending:
a) Bends whose radii range from 3 to 5 times, the nominal pipe diameter will offer the least
pressure drop.
b) The minimum radius of Curvature in cold bending and hot bending without filler
should be at least 4 and 3 to 3.5 times OD of the pipe respectively.
34
c) Thinning: In every bending operation, the outer portion of the bend (extrados) stretches
and the inner portion (intrados) compresses. The Codes require that the wall thickness at
the extrados after bending be at least equal to the minimum wall thickness required for
straight pipe. The wall thickness (schedule) should be selected accordingly.
c) Ovality: The degree of ovality is determined by the difference between the major
and minor axes divided by the nominal diameter of the pipe.
Dmax - Dmin
Ovality = ---------------- * 100 Where Dmax = Maximum Diameter
Original D Dmini = Minimum Diameter
Where the bend is subjected to internal pressure, the pressure tries to reround the cross
section by creating secondary stresses in the hoop direction. Some codes consider an
ovality of 8% acceptable in this case. Where the bend is subject to external pressure,
the pressure tries to collapse the cross section. The ASME B31.3 code recommends a
3% maximum ovality.
v Carbon steel piping is usable upto 482oC. But it is limited by strength consideration as,
above 425oC permissible working stresses fall so sharply that its use is no longer
economic.
v Pickling is done to remove mild scale from the surface of components. Minimum inside
dimension of pickling tank shall be 7.8 - 9 meter long, 1 meter deep and 1.4 meter side.
a) Picking of carbon steel pipes will be done with the concentration of acid approximately
15% by weight of H2SO4 and 0.10% of inhibitor corobit-1001 at 49 to 55oC for
about 10 to 15 minutes. Neutralise with 2% Caustic Soda solution for about 5 to 10
minutes.
b) Degalvanising (removal of zinc coating) of G.I pipe ends for welding of GI pipes will be
done with concentration of acid approximately 8% by weight of H2SO4 and 0.10%
inhabitor Corobit. 80mm shall be dipped in the acid bath for about 45 - 50 minutes.
Neutralise 2% NaOH solution for 5 to 10 minutes.
v Pipe Insulation:
The reason for insulating the pipe is to minimize the heat loss from the surface.
a) According to the U.S Department of Energy’s Best Practices Steam Program,
Mechanical insulations should be used on any surface over 120oF (49oC).
b) Potential Saving from Insulation application and upgrades may reduce fuel consumption
any where from 3% to 13%, according to the U.S DOE’s Industrial Assessment Center
Program.
c) Installation: Two prime considerations are “Whether the insulation is dry and snugly fitted
and whether there is enough of it”, suggests Don Wulfinghoff, author of the Energy
Efficiency Manual.
v Types of Insulations:
a) Expanded polystyrene type SE (Self extinguishing) used on cold carbon steel Piping, G-
I ducting and cold stainless steel piping and equipment. Thermal conductivity or “K” value is
0.03526 Kcal/hr. m.oC. at 50oC mean test temperature.
35
b) Mineral wool (No glass wool) used on hot carbon steel and stainless steel piping and
equipments “K” value is 0.077 Kcal./hr. moC at 300oC mean test temperature. This is
suitable for use upto 600oC.
c) Calcium Silicate used for turbine and associated equipment. “K” value is 0.077
Kcal/hr.m.oC at 300oC mean test temperature. This is suitable for application upto 600oC.
v The pipe supports shall be designed to allow free expansion and contraction of pipe
without causing excessive strains in pipe, anchors or supports.
v Flanges:
a) A flange with raised face should never be joined to one with a plain face.
b) Flanges with 1/16” or ¼” raised face may be faced smooth or finished with concentric
or spiral grooves not over 1/32” deep, 16 per inch. for cast iron and 32 per inch. for
steel.
c) Slip-on welding flanges limited service pressure is 300 psi
d) The internal dia. of Socket weld flanges should be 1.5 mm (1/16 inches) larger than the
outer diameter of pipe.
e) Flange bolt holes - For ½” and 5/8” bolts, the dia. of holes should be 1/16” larger. For
bigger size of bolts, the dia. of holes should be 1/8” larger than the dia. bolts.
f) Pressure temperature Rating of Flanges: Standard flanges may be used at pressure
above the rating pressure for working temperature below 850oF (455oC).
36
6. Valves and Actuators
v Trim: Valve trim in general, is all removable parts of the valve in contact with the
process fluid.
v Valve Characteristic: Relationship between the travel of the valve closing element and
the corresponding flow through the valve is called valve characteristics.
v Inherent flow characteristic: The flow through the valve is pressure dependant.
However the valve manufacturer does not know the pressure differential across the
valve after it is installed in a system. That is why valves are tested by the manufacturers
and flow characteristic produced at a constant pressure differential. This characteristic
provided by the manufacturer is called inherent flow characteristic.
v Valve gain or Sensitivity: It is defined as the ratio of the change in flow to the change
in travel when there is a constant differential pressure across it. In reality the gain is the
slope of the valve characteristic.
v Linear flow characteristic: The linear flow characteristic produces flow directly
proportional to the Valve travel. The Valve gain will be constant at all flows. The linear
characteristic valves can be kept approximately constant because this makes the flow-
rate proportional to the valve travel.
37
Modified parabolic characteristic: It falls between the equal percentage and linear
characteristics. This characteristic also produces an increasing gain with increasing valve
openings. Modified parabolic valves are sometimes substituted for equal percentage valves.
Mainly butterfly, ball and plug valves and even some gate valves produce this type of
characteristic.
v Carbon and alloy steel valves, forged valves predominate in the smaller sizes, and cast
valves in the larger sizes.
v SAFETY&RELIEF VALVES:
a) Generally Safety/Relief Valve blow off set pressure is 10% greater than the
Working pressure and Reseating pressure should be less than 5% of the set pressure.
b) Safety Valves: Safety valves are designed to have a full opening pop action to provide
immediate relief. Section VIII of the ASME Code requires these valves. Capacity,
overpressure and blow down for safety valves are specified in the code. Safety valves are
usually employed to relieve excessive pressure build-up, caused by gases (compressible
fluids).
Set pressure opening tolerances for Safety Relief Valves
Up to 70 PSI + 2PSI
71 to 300 PSI + 3% of set pressure
301 to 1000 PSI + 10 PSI
> 1000 + 1% of set pressure
Ø According to the Indian boiler regulations, the essential requirements of any Safety
valve is that its area should be sufficient to discharge the steam as quickly as it is
generated with rise in pressure not more than 10% of the safety valve blow off pressure.
Ø The blow off pressure of a boiler safety valve is 106% of boiler working pressure.
c) Relief Valve: Relief valves are used to relieve excessive pressure build-up
caused by no compressible fluids. These are designed to open slowly with increase in
initial pressure. These valves do not have a code design.
Liquid – Relief valve reach their rated capacity at no more than 25% over pressure.
Up to 70 PSI + 2 PSI
Ø 70 PSI + 3% of set pressure
v Safety & Relief Valves In gas and vapour valves, static pressure opens the disc and
dynamic force keeps it open. The increasing fluid velocity creates this force in the
38
conical nozzle below the valve disc and the bell-shaped underside of the disc, called the
huddling chamber. The huddling chamber diverts the gas flow. The velocity of the
mass of gas, and the diversion are proportional to the force that keeps the valve seat
open.
In Safety relief valves, an adjustable blow down ring protrudes into the huddling
chamber.
v As per Manufacturer standard specification (MSS), the maximum permissible leak rate
during the seat test on gate, globe, and Angle valves and check valves is as follows.
Hydrostatic test – 10cc) | per hour per 25 mm (1 inch) diameter of nominal valve
Air test - 1/10SCF) | size.
v Check Valve:
a) For vertical/horizontal installation manufacturer recommendation is to be followed for
check valves.
b) Check valve and globe valve flow direction to be checked before installation.
c) Do not use a swing check valve on reciprocating liquid pumps, always use a vertical -
lift type.
v Check the gland bush for general condition. The inner radial clearance should be
0.4mm (0.016”) maximum and the outer radial clearance should be 0.25mm (0.010”)
maximum to never risk of cocking or touching on the stem.
v Check the clearance between bonnet and stem and if it is greater than 0.25mm (0.010”)
radially, then it is useful to employ a thin close clearance spacer ring in the bottom of
stuffing box to prevent the risk of packing extrusion.
v Bellow Seal Valve: Bellows are made out of Inconel –600 and have been designed
for a minimum number of 5000 Cycles of operation. The normal travel of the valve will
be 15% of the total length of the bellow.
v Ball Valve:
a) Valve goes from full open to full close in Quarter-turn of the stem. (A plug valve –too)
b) Visual Clarity: When the handle is parallel to the pipe the valve is open and when
perpendicular, the valve is closed.
39
c) Size: Vertical size of 1” ball value varies from 2¼” to 4” depending upon the
manufacturer. A comparable gate and globe valve in the open position required from
8” to 14” and 5” to 12” respectively.
The vertical size of 1” plug valve is 4” to 7”.
d) Weight: A 1” ball valve weighs between 3.5 to 10 Kg. (1.6 to 4.5 lb.) whereas
comparable conventional valves weigh between 8.8 to 94.6 Kg. (4 to 43 lb).
e) Lubrication: A ball valve does not have to be lubricated. So it is easier to operate
automatically.
f) Flow loss: Straight – through flow, reduce turbulence and minimise head loss.
g) Limitations: Low pressure and low temperature application. Not recommended for
throttling service.
v Hopkinson Valve:
a) Purpose of Belleville washes is for live loading of gland packing and compactness in
size. Load Vs deflection after the pre-loading is constant.
b) Helium leak check to the stuffing box after the replacement of gland packing is done
at 15 PSI pressure for half an hour and leak check probing is done at leak off point and
at follower/stem area. Leak rate should be less than 10-4 Std.cc /sec.
Helium inter gasket hold test at 100 PSI. for half an hour is carried out to ensure Bonnet
gasket leak tight joint.
c) The valve shall not be operated if differential pressure across the seat exceeds 14
Kg/cm2. (Note: To be checked by its logic or torque development is more.)
d) Belleville washer spring deflects axially under load may be used series or parallel
arrangements to give lower or higher stiffness respectively. The spring is space saving
and its non-linear characteristics can be altered considerably by varying the proportions.
v Actuators: The Valve actuators can be inactive for up to 99% of their working life.
The only exception is control valve actuation, but even here the activity is rarely
continuous.
a) Manually operated valves are shut off by the operators feeling.
b) Electrical operated actuators torque switch gives the actuator to “feel” valve
tightness with much greater precision and repeatability than any man.
c) Wedge gates, globe valves and Diaphragm valves are required torque (Seating)
Switch for closing limitation and position limit switch for opening.
d) Parallel slide valves, plug and ball valves require open and close position limit
switches and torque switch for protection.
e) Bufferfly valves: Non-seating type requires position limit both ways with closing
torque switch for protection. Seating type requires position limit for opening and
torque limit for closing.
f) Back seating under power is not generally recommended. (if required, being
achieved manually).
g) Limit switches are operated by valve stem moment or by counter mechanism drive.
h) Torque switches are operated by the reaction force on the worm shaft in direct
proportional to the output torque.
i) As the torque applied to the output shaft increases, the worm shaft moves axially,
compressing the spring pack in either direction to trip open or close torque switch.
j) Backlash hammer blow is incorporated to assist unseating.
40
7. Heat Exchangers
v The Overall efficiency of the plant depends largely upon the efficiency of the heat
exchangers.
v Water velocity in the tube is limited approximately 8ft/sec. usually between 6.5 and
8ft/sec. Lower velocity (i.e.) less than 6.5 increases size and cost of equipment. Higher
velocity limit is to reduce tube erosion and pumping cost. MAPS main condenser water
velocity is 5ft. /sec.
v In general, roughening the surface or turbulent flow will increase the heat transfer Co-
efficient.
v Tube diameter must be selected on the basis of thermal and space requirement. Smaller
will have higher heat transfer co-efficient and larger ones carry more circulating water at
given velocity with less pressure drop.
v Tube length must be determined by 1) Space limitation (space must be provided for
pulling tubes 2) Initial cost 3) Pumping cost
v Tubes will occupy between 20 to 25% of the cross section area of the condenser.
v Thermal conductivity of one-inch thickness of a material is twelve times more than one-
foot thickness of same material.
v Water has the highest thermal conductivity of all the non-metallic liquids.
v Highest thermal conductivity gas is Hydrogen among all the gases and vapours.
v Cooling Tower:
a) Cooling Tower Approach is defined as the difference between the cold water
temperature (outlet water temperature) and WBT of in coming air. Higher the quantity
of water will lower the cooling tower approach.
b) Cooling range is the difference between the hot water and cold water temperatures.
c) Performance of cooling tower is measured in term of its efficiency
Twi-Two | where Twi = temperature of water in let,
? = -------------- | Two = temperature of water out let,
Twi-Twba | Twba = wet bulb temperature of inlet air.
d) Method of heat transfer in Cooling Tower: In a cooling tower, finely divided water falls
through an air stream whose wet-bulb temperature is below that of the water. The
evaporation of a small portion of the water causes the air to absorb heat from the
remaining water, due to the latent heat of the evaporating water.
The evaporation of 1 lb of water absorbs about 1000 Btu. Thus, the evaporation of 1 lb
of water cools 100 lb of water through a 10-degree cooling range.
In addition, a small amount of sensible heat is transferred because of the temperature
differential between the water and air (dry-bulb temperature).
41
e) The performance of the cooling tower is independent of the dry-bulb temperature of the
air and dependent only on the wet-bulb temperature of the air in contact with the
water.
f) The forced draft fan is more efficient than the induced draft by about 3%, because some
of the fan velocity pressure is converted to static pressure in the tower.
g) The number of fan blades varies from two to six. In general, the greater the number of
blades the smother the operation; however it trends to reduce the efficiency of the fan
because of interference between blades.
h) A two bladed fan because the air time which elapses blade passing is so great that the Air
flow is actually reversed, causing the pulsation, vibrating the entire structure, where as with a
six blade fan, the pulsation disappears entirely.
v Tube leaks checks are done by Hydro test (water level) 1 foot above from the top most
row, Helium test (during S/D) Vacuum hold test and Candle flame test (during on
power in condenser).
v After eddy current testing of heat exchanger tubes, if the wall thickness reduces by 40%
of the original thickness, the tube shall be plugged.
v Maximum 10% of tubes can be plugged in the heat exchangers without affecting the
performance.
v Leaky tubes are plugged with taper plug / plugged with taper plug and welded depends
upon rating.
v Rule of thumb for computing Condensing Rate for water heaters: Raising the
temperature of 100 gallons of water 1oF will condense one pound of steam.
v Heat flux is the amount of heat transfer per unit area per unit time.
42
h) Withstand Thermal Shocks
i) Vibration free
j) Cleaning is easy due to full access.
v Tube Pitches:
The tube pitch is the shortest center to center distance between adjacent tubes.
a) Tubes are laid out on either square or triangular pitch pattern.
b) Steam condenser and oil coolers etc. have Square pitch and the outside of tubes
can be easily cleaned.
c) Triangular pitch HX is able to accommodate more number of tubes in the same
inside pipe diameter.
d) Modified triangular pitch provides the access for mechanical cleaning.
v Baffles:
a) Baffles induce turbulence and Zigzag path on shell side liquids and increases higher
heat transfer co-efficient results.
b) The Center-to-Center distance between baffles is called the baffles pitch or baffles
spacing.
c) The spacing is usually not greater than a distance equal to the inside diameter of the
shell or closer than equal to 1/5th of the inside diameter of the shell.
v Fixed Tube Sheet HXs are normally provided with expansion joint on shell to take
care the thermal stress developed across the tube sheet.
v 1-2 Pass HX in which the shell side fluid flows in one pass and the tube fluid in two
passes.
v Pull through floating head eliminates the differential expansion problem and possible
to insert lesser number of tubes only, where number of tubes could have been inserted
in place of the bolt circle wasted to bolt the tube sheet cover.
43
c) The main advantage is that the tube bundle can be taken outside of the shell for
inspection and cleaning and for any other maintenance required.
d) Fewer tube replacement is not possible. Complete tube bundle has to be replaced.
Also cleaning tube bundle from outside is very difficult due to compactness.
v For a given pressure drop, higher heat transfer co-efficient are obtained on the shell
side than on tube side.
v Cleaning of Tubes:
a) Mechanical cleaning-Care should be taken not to damage the inside surface of tubes.
b) Circulating hot water / oil / light distillates.
c) Commercial cleaning compounds / Chemicals.
44
d) High pressure water jet cleaning.
e) Tubes should never be cleaned by blowing steam through the individual tubes.
v PERFORMANCE FAILURES:
The failure of heat exchanger equipment to perform satisfactory function may be caused
by one or more of the following factors.
a) Excessive fouling.
b) Air or gas binding resulting from improper piping installation or lack of vents.
c) Operating condition differing from design conditions.
d) Mal distribution of flow in the unit due to choking of inlet and outlet nozzles.
Generally the inlet nozzles are chocked more than the outlet nozzles.
e) Excessive clearance between the baffles and the shell and or tubes, due to
corrosion.
f) Improper thermal design.
v FOULING FACTORS:
A fouling factor (fouling resistance) is really a safety factor to avoid reduced
performance or to avoid too frequent cleaning). A 25% increase in fouling factor may
result in a 50% or more decrease in the performance of the heat exchanger.
45
8. Compressor
v Equipment categorised based on pressure is upto 2 Psig for Fan, 2 to 10 Psig. for
blower and More than 10 Psig. for Compressor.
v Compressor Valves:
a) If, due to wear, the total indentation of valve plate and seat is over 0.2mm, the valve ring
and or the seat must be replaced.
b) Valve plates can be lapped up to 20% of valve plate initial thickness.
c) Kerosene leak check is to be done after assemble the suction and discharge valves.
The valve lift is to be between 2 to 2.5mm.
d) Finger type valves are normally used for small units 3/4 to 5 HP size.
e) More than 5 HP have concentric ring type valves.
v If normal air delivery has dropped off or if oil consumption of the compressor is
considered to be excessive, piston ring broken or worn may be the one of the cause.
v Compressor rings and oil rings are classed as different types. Make sure that the rings
are properly positioned which can be identified by the word `top', the letter `T', a dash
(-), a dot (.) or a paint mark.
v Normally 10% of leakage in the pipelines will be allowed for piping and tool leakage.
v Usual limiting compression ratio per stage for various types of positive displacement
compressors in capacities up to 1000 cfm are
46
v Compressor Capacity Regulation
a) Small compressor upto 25 HP can have ON-OFF control when adequate air storage is
available and the air requirement is less than 75% of the compressor delivery capacity.
b) Constant speed unloading is used when the demand for air is practically constant at the
capacity of compressor.
c) Constant speed intake unloading (using Auxiliary Valve)
d) Constant speed free air unloading (using unloader piston and suction valve).
e) Recirculation by valve control method.
f) Clearance volume control usually in three or five steps, which decrease in volumetric
efficiency and capacity.
g) Compressor motor unload current is 50% of full load current (Motor no load current is
40%).
h) Air storage receivers should be sized for about 9 - 18 Litres Capacity/ CFM of
compressor capacity for effective demand side control.
v To establish the size of the storage tank for a given compressor capacity, the following
formula can be used.
Compressor output (Cfm * Psia)
3
Receiver Size (ft ) = ----------------------------------------
Output pressure (Psig. + Psia.)
v Purpose of inter cooler is to reduce the air temperature, reduces specific volume of air
to be handled in the next stage, increases the volumetric efficiency and thus reduces the
power input to the prime mover.
________
a) Inter cooler pressure (P2) = √P1 * P3 | Where P1 = Initial Pressure
| P3 = Final Pressure
b) Each 10oF air temperature decrease in intercooler outlet result in 1% saving in
power input.
v Each 10oF change in inlet air temperature to Compressor affects efficiency by 1%.
Colder temperature increases and warmer temperature decreases efficiency.
v The speed of compressors is controlled by the piston speed, which are normally about
5 metres/sec. for small machines and about 4 metres/sec. for larger ones.
v Ratio of compression per stage seldom exceeds 7 usually average 2 or 3 on multi stage.
47
b) Better mechanical balance and uniform torque.
c) Lighter Cylinder.
d) Reduce leakage losses
e) Reduction in power required driving the Compressor.
f) Effective lubrication is possible due to lower temperature range.
v Moisture Condensation
a) As air is compressed and cooled, which reduces the volume of each kilogram of air, the
ability for it to contain water as vapour becomes less. Finally water vapour condenses
and appears in the air in liquid state.
b) The temperature and the volume (not the pressure) determine moisture capacity of air.
The moisture capacity increased as the temperature increases. E.g. 1000cfm of
saturated air (i.e. 100% R.H) at 80oF will contain 1.57 lb of moisture. At 100oF it can
contain 285 lbs.
c) Under average conditions, every 100 CFM of air compressed to 100 Psig. produces
20 gallons of condensate per day.
d) 1000 ft3 of air after compression can release 1.3 litres of water.
e) A good after cooler cool the air within 15oF of the cooling water temperature and will
condense 90% of water vapour originally contained in the air as it enter the receiver
tank.
f) Most water cooled after coolers will require cooling water about 3 gpm.per 100 CFM
of compressed air at a discharge pressures of 100 Psig.
v Sliding vane:
a) A running sliding vane compressor gives off large amount of heat due to mechanical
friction. Therefore, at compression above 1.5 the compressor casing is water-cooled.
b) Generally machines for pressure above 50 psi are built as two stage units.
v Screw compressor shows higher efficiency than sliding vane compressor due to
absence of mechanical friction.
v Intake Pipe : Intake pipe size should be at least one size higher for every 10 ft. in length
keep intake air velocity below 2500 f.p.m.
v Jacket Cooling: Jacket water pressure should never exceed 40 PSI, a much lower
pressure being preferred, to avoid any possibility of leakage. For water cooled system,
cooling water will first go to inter cooler then carried to cylinder. This is to ensure that
48
no sweating takes place on cylinder walls. Recommended water temperature at outlet is
260 C (800 F) to 370 C (1000 F)?(lukewarm).
a) Single Acting Compressors are those in which suction, compression and delivery of
a gas take place on one side of the piston and we have one cycle/revolution of
crankshaft.
b) Double acting compressors are those in which suction, compression and delivery of
a gas take place on both sides of piston and we have two cycles/revolution of
crankshaft.
c) Single stage compressors are those in which the compression of air from the initial
pressure to final pressure is carried out one cylinder only.
d) Multistage Compressors Compressions more than one cylinder.
e) Ratio of Compression is defined as the ratio of absolute discharge pressure to
absolute intake pressure.
49
f) Free air is that which exists under the condition of pressure and temperature at the
intake of compressor.
g) Displacement of compressor is the volume swept through by the first stage piston or
pistons in cubic metre per minute. In double acting compressors, it is the volume
swept through by both sides of the piston.
h) Actual Capacity of a Compressor is the quantity of gas actually delivered. It is
expressed in cubic metre of free gasper minute. The actual capacity of a
compressor is always less than its displacement.
i) Volumetric/Efficiency is the ratio of the actual capacity of a compressor to its
displacement.
j) Standard Cubic feet per minute (SCFM). Flow of free air measured at a reference
point and converted to a standard set of reference conditions. (eg: 1.03Kg/cm2a,
15oC and 0% relative humidity)
50
9. Diesel Engine
v Dust particles in Industrial atmosphere can contain about 40 million in 1m3 of air. If the
air volume is reduced to 7 times to give 7 bar of air pressure, the concentration of dust
particles would be 280 mppm3.
v The difference between IHP and BHP of an engine is due to friction loss of the engine.
Higher Lower
Diesel - 46000 43250
Kerosene - 46250 43250
Petrol - 47000 43900
51
v Fuel injector is like a spring loaded check valve with nozzles having fine holes of
0.006" to 0.008" dia.
v Connecting rod crank pin bore and piston pin should be paralleled within 1 thou in 6
inch. both in Horizontal and Vertical position. Bore finish must be smooth enough (80
micro inches) to ensure proper bearing contact and heat transfer.
v Connecting rods are graded by weight, letters L or R and Cylinder No. Where a new
connecting rod is required, it is essential to quote the grade letter and Cylinder No. (As
per the Station DG Manual).
v Ensure Cylinder No. and arrow mark on piston before assembling of piston to
connecting rod.
52
v The requirement of Chimney height above the roof of Diesel Engine is 0.2 * √KVA as
per ISO 14001. This is applicable to > 50 KW diesel engine (KVA = KW/Power
Factor).
v Crankcase ventilation:
It is possible that the products of combustion may leak to the crankcase. They mainly
contain Nitrogen, Carbon-di-oxide and Water. They may also contain traces of acid
due to presence of sulfur in the fuel. The acid causes corrosion of engine parts.
Crankcase ventilation is a remedial measure taken to avoid effect of acid on parts in
its contact. A steady flow of air is carried through the engine crankcase, which carries
away the products of combustion along with it. An exhaust fan is normally used for
crankcase ventilation.
a) Never open the door of a totally and closed crankcase until the engine is cooled off.
Over-rich mixture of oil vapour may get ignited when the fresh air is admitted.
v Frequently inspect the engine for leaks, loose fasteners, abnormal mechanical noises and
temperature.
v Diesel engines have higher compression ratio (16:1 to 22:1) than gasoline engine (8:1)
because they relay on high compression to create heat for fuel ignition.
v Cylinder:
a) Single cylinder engines: The maximum size of the single cylinder engine is restricted to
about 500-600 ' c.c,' because of the higher unbalance forces, which become difficult to be
balanced. Further the weight of the flywheel required becomes excessive for higher engine
sizes.
b) Two cylinder engines: This type of engine, apart from providing more power, gives
more uniform torque and balancing possible is also better as compared to single
cylinder engines.
c) V-type: In this two cylinders are placed with their centre line at same angle to each
other. Generally this angle is kept 60°. But in some instances angles from 40" to 90° have
also been used. Its main advantage is that it can be made more compact, e.g. same
crankcase as used in a single cylinder engine may be used here also. Further short
crankshaft also means more rigidity, due to which the engine runs more smoothly at higher
speeds. Besides, overall length and height of the engine are decreased. The weight/volume
ratio is lower compared to an in-line engine. However, cost or manufacture is high and
balancing more difficult.
d) Water cooled engines: The inlet to the jacket is given from the bottom, water while
flowing upwards gains heat from the cylinder and cylinder head, and is then removed from
outlet provided at the top of head.
e) The Quantity of water circulated is 1.5 litres /min. /HP corresponds to 8oC rise.
f) Re-boring is done when the?cylinder is worn out 0.007" per inch of bore. Re-bore to
0.001 to 0.005" within the desired measure.
53
v Firing Order: The firing sequence is arranged in a predetermined manner to give the
best engine performance in terms of uniform rotation, equally spaced power impulse and
proper balancing.
v The material of which the combustion chamber is made and the efficiency of the cooling
system also has distinct bearing on the compression ratio that can be used in the given
engine.
Example: Aluminium pistons and Aluminium cylinder heads can operate at higher
compression ratio than could cast Iron or Steel.
v The mating surfaces of cylinder head surface and cylinder block surface should be flat
and true within 0.5 mm (020 inch). Measurement is made by means of a metal straight
edge and feeler gauge strips.
v In general, it is customary to have clearance fit between solid skirt cast Iron piston to
cylinder to about 0.00075 to 0.001 inch per inch of diameter.
54
The poppet valve derives its name from its motion of popping up and down. This is
also called "mushroom valve" because of its shape, which is similar to a mushroom. It
consists of a head and a stem. It possesses certain advantages over the other valve
types because of which it is extensively used- in the engines :
1. Simplicity of construction, 2. These are self-centering,
3. These are free to rotate about the stem to new position.
4. Maintenance of sealing efficiency is relatively easier.
Generally inlet valves are larger than the exhaust valves, because speed of incoming
air is less than the velocity of exhaust gases which leave under pressure. Further
because of pressure, the density of exhaust gases is also comparatively high.
Moreover, smaller exhaust valve is also preferred because of shorter path of heat
flow. Generally inlet valves and exhaust valves are 45% and 38% of the cylinder bore
respectively.
v Air Motor:
a) A drop of 10 Psi. at the inlet reduces the air motor’s output by 14%, a drop of 30
PSI. Could affect the output by as much as 45%.
b) One of the major advantages of an air motor is in terms of its ability to come up to
full speed almost instantly.
c) It is generally accepted rule that if a rotor blade losses 20% or more of its width, it
should be replaced.
d) A helpful rule for the maintenance department would be that an Air tool should be
scrapped if its repair cost exceeds 50% of the cost of replacement.
v Air tool hose size : The correct size is usually one size larger than the inlet thread on
the tool. About 60% of air tools returned for repair have reduced nipple inserted at the
air inlet, which causes reduction of air power, and their use should be discouraged.
55
Ø Compression pressure, fuel-injection timing, condition of fuel-injection system,
and fuel-oil characteristics affect combustion pressure. Combustion pressure
should be kept within 25 psi of the normal.
b) Exhaust Temperature is a sensitive and direct indication of proper combustion. The
most efficient performance brings the lowest temperature; irregularities or deficiencies
of combustion always bring temperatures above normal.
c) Fuel consumption is a simple and sure overall measure of engine performance. Meters
or measuring tanks may be used for checking consumption.
d) Lubricating-Oil Pressure Abnormally low lubricating oil pressure is dangerous; low-
pressure shutdown devices or alarms are frequently used. Abnormally large
pressure drop through the filter indicated clogging; low pressure drop indicated a
break in filter medium. Rise in oil temperature indicates hot bearing; Watch for
contamination from fuel oil, because this indicates poor combustion conditions.
Water in the oil indicates leaks from jackets or head gaskets. Metal particles may
be abnormal wear or breaking up of Babbitt in the bearings. Abnormal quantity of
sludge may indicate poor combustion or unsatisfactory type of lubricating oil for the
engine and service conditions.
e) General Observations . Any unusual sound or symptom must be promptly investigated.
Whenever any inspection work is done on an engine, extend the inspection to cover
other parts that can be conveniently inspected at the same time. Similarly, when
maintenance work is done on one part or assembly, recondition all parts in the
assembly fully, as well as in any other assemblies or parts that can be conveniently
handled at the same time.
56
work in a lesser time would require more power.
10. Horse Power (H.P.): This is the amount of energy required to do 4500 Kgm. of
work in one minute.
11. Indicated horse power (I.H.P.): The power developed within the engine cylinders is
called indicated horse power, This is calculated from the area of the
engine indicator diagram.
12. Brake horse power (B.H.P.): This is the actual power delivered at the crankshaft. It is
obtained by deducting various power loses in the engine from the indicated horse power.
13. Engine torque: It is the force of rotation acting about the crankshaft axis at any
given instant of time. It is expressed in Newton-metres (Nm).
57
10. Fans and Blowers
v Purpose of a “FAN” is to move a mass of gas or Vapour at the desired velocity. There
is a slight increase in the gas pressure across the fan rotor or impeller & volute casing.
However, the main aim remains to move air or gas without any appreciable increase in
its pressure. The total pressure developed by fans is of the order of a few millimeters of
water gauge.
v A “BLOWER” delivers the gas or air with an appreciable rise in pressure to overcome
some kind of resistance in the flow. In some applications they develop pressures of the
order of 1000 mm W.G. or more.
v Fan shaft:
a) Shaft, which operates below 70% of their critical speed, is considered Rigid Shaft.
Above 70% considered flexible shaft.
b) If fan is required to run above critical speed, it is better to design 20 to 30% above
the critical speed.
c) Generally fan shaft diameter is higher than Centrifugal pump shaft for the same
BHP.
v SISW: Single Inlet Single Width impeller. Lock the impeller 1/3 movement from
suction side of the total end ply in volute casing.
v DIDW: Double Inlet Double Width impeller. Lock the impeller center of Volute
casing of the total end ply.
v The position of fan wheel with respect to the inlet is important for noise and efficiency.
As a general rule operation as close as possible without actual striking is the correct
positions.
v A damper at the fan inlet is most essential that all moving joints of these dampers be
carefully and thoroughly lubricated at least once each month. Observation may indicate
the need for more frequent maintenance attention under severs conditions.
v Belt Guards:
58
A V belt drive is a friction drive, and as such will generate heat, air should be allowed
to circulate freely around all parts of the drive to help dissipate this heat. It is not good
practice to completely enclose V-belt drives. Use open mask guards if possible.
Application categories and required balancing grade
v Centrifugal Fan: Wide ranges, Less noise, more efficient, High pressure, Airflow
variation is easy, Low specific speeds.
a) FORWARD CURVED BLADE FAN:
The pressure rises from 100 % free delivery toward no delivery with a characteristic dip at
low capacities. Horsepower continuously with increasing air quantity.
b) BACKWARD CURVED BLADE FAN:
The pressure rises constantly from 100% free delivery to nearly no delivery. There is no dip
in the curve. The horsepower curve peaks at high capacities. Therefore, a motor selected to
satisfy the maximum power demand at a given fan speed does not overload at any joint on
the curve, providing this speed is maintained.
Two modifications of the backward curved blade fan are the airfoil and backward
inclined blade fans.
c) RADIAL BLADE FAN:
The pressure characteristic is continuous at all capacities. Horsepower rises with increasing
in air quantity in an almost directly proportional relation. Thus, with type of fan the motor
may be overloaded as free air delivery is approached. The radial blade fan has efficiency,
speed and capacity characteristics that are midway between the forward curved and
backward curved blade fans. It is seldom used in air conditioning applications because it
locks an optimum characteristic.
v Axial Fan:
Large volume of discharge, Higher noise level, High specific speeds.
59
a) Condition monitoring by vibration reading.
b) Regreasing as per Schedule/Experience
c) Ensure proper condensate draining
d) Plummer block (bearing) temperature should not exceed 55oC. on surface.
e) Condition and tension of belts
f) Free operation of inlet vanes/outlet damper and links regreasing.
g) Current drawing of fan motor
h) Noise level
v In a well-balanced and properly installed fan, the mechanical noise originating from
bearings and vibration of various parts is not as prominent as the aerodynamically
generated noise is due to the various flow phenomena occurring within the fan.
The main causes of aerodynamically generated noise are:
a) The flow at the entry and exit of the fan, i.e., Suction and exhaust noise,
b) Rotation of blades through air or gas, c) Passage of blades through wakes,
d) Turbulence of air, e) Shedding of vortices from blades, and
f) Separation, stalling and surging.
STANDARD AIR DENSITY is 0.075 lb per cu ft at sea level (29.92 in. barometric
pressure), dry air, and 70o F
VOLUME handled by a fan is the number of cubic feet of air per minute (cfm)
expressed at fan outlet conditions
TOTAL PRESSURE of a fan is the rise of pressure from fan inlet to fan outlet
STATIC PRESSURE of a fan is total pressure minus the fan velocity pressure
POWER OUTPUT of a fan is expressed in horsepower and is based on fan volume and
fan total pressure.
60
MECHANICAL EFFICIENCY of a fan is ratio of power output to power input
STATIC EFFICIENCY if a fan is the mechanical efficiency multiplied by the ratio of static
pressure to the total pressure
FAN OUTLET AREA is the inside area of the fan outlet (flange)
Air Density 7. Capacity varies as the cube of the size Q1/Q2 = (D1/D2) 3
Speed 8. Pressure varies as the square of the size P1/ P2 = (D1/D2) 2
9. Horsepower varies as the fifth power of the size HP1/HP2 =
(D1/D2) 5
----------------------------------------------------------------------------------------------------------
Air Pressure 10.Speed, capacity and Horsepower vary inversely as the square
root Density Fan Size of the densityN1/N2 = Q1/Q2 = HP1/HP2 =
(W2/W1) 1/2
Distribution 11.Pressure and Horsepower vary as the Density P1/P2 = HP1/HP2
System =
W1/W2
12. Speed remains constant N1 =
N2
-----------------------------------------------------------------------------------------------------------
61
In addition to the restrictions noted in Table -application of these laws is limited to cases
where fans are geometrically similar and where there is no change in the point of rating on
the performance curves. Because of the latter qualification, fan efficiencies are assumed
constant.
Geometrically similar fans are those in which all dimensions are proportional to fan wheel
diameter. The same point of rating for two fans of different size means that for each fan the
pressure and air volume at the point of rating are the same fraction of shut-off pressure and
volume at free delivery provided the rotational speed is the same in either case.
62
11. Refrigeration
v The minimum HP requirement per tonne of Refrigeration using R-11 is 0.9383 and
R-22 is 1.0114.
v Flooded evaporator will transfer about 50% more heat than direct expansion
evaporators because of good contact with evaporator surface.
v Thermostatic expansion valves controls the flow of refrigerant into the evaporator in
an amount that exactly matches the evaporation rate of the refrigerant in the
evaporator.
a) Thermostatic expansion valves act in response to the temperature of the suction gas as
it leaves the evaporator, along with refrigerator pressure inside the evaporator.
b) The three forces that operate a thermostatic expansion valve are:
• The pressure inside the remote bulb and power element.
• The pressure inside the evaporator.
• The pressure of the super heat spring.
63
c) Thermostatic expansion valves are designed so that an increase of 4oF Super heat
will cause the valve to completely open.
d) Thermostatic Expansion Valve Remote bulb installation.
On suction lines smaller than 7/8” OD, the bulb may be installed on top of the line.
On lines larger than 7/8” OD, the bulb should be mounted at about the 4 or 8-O’
clock position. It is preferred that the bulb is installed on a horizontal of the suction
line. If it must be installed in a vertical position, the bulb must be installed so that the
Capillary tubing extends from the top of the bulb.
v Refrigerant cylinders are normally filled only about 74% liquid full at 80oF (27oC).
64
v Numerical Designations of Refrigerants:
a) The first digit on the right is the number of fluorine atoms.
b) The second digit from the right is one more than the number of hydrogen atoms.
c) The third digit from the right is one less than the number of carbon atoms.
v Refrigerant circulated lbs/min/ton for HFC 134a is 3.00 and for HCFC 22 is 2.78.
v HFC-134 a requires 3.17 cfm/ton, while HCFC-22 requires 1.83 cfm/ton of cooling.
v The concentration of natural chlorine in the stratosphere is about 0.6 parts per billion in
1985; currently it is 3.0 parts per billion levels and still raising.
65
v About 50% of the predicated globle warming is attributed to the emissions of carbon di-
oxide. R-11 & R-12 (CFCs) are responsible for about 15% to 20% of the gases.
v Each module of CFC gases gas approximately 20,000 times more impact on the global
climate than CO2. The control of CFCs more important than controlling CO2 in the
preventing of global warming.
v Relative Humidity is the ratio between the mass of water vapour actually present in a
certain volume of air at any temperature and pressure and the mass required to saturate
it under the same conditions.
v Condenser:
a) It is generally assumed that air-cooled condenser will have a condensing temperature of
about 14oC (25oF) to 19.5oC (35oF) higher than the ambient temperature.
b) Water cooled condensers generally operate with a condensing temperature that is lower
than the surrounding ambient temperature.
c) In Condenser the amount of heat is given up by the refrigerant must always equal to the
amount of heat gained by the cooling medium.
d) The amount of sensible heat removed in the condenser is very small when compared to
the amount of latent heat removed.
e) The condensers are specifically designed to hold the entire refrigerant charge.
66
12. Turbine
v `U’ loops or expansion loop ensure flexibility of piping between chests and casing and
ensures that the lateral stress due to pipe and casing expansion will be equalised from
both sides of casing. Thus the stress on the turbine casing due to metal expansion is
minimized.
v Where steam pressure is > 1000 PSI, the H.P Cylinder is generally of double shell
design.
v The process of providing an arrangement, which will keep rotor speed as closers
constant, irrespective of load conditions is known as Governing of Steam Turbine.
v Modern steam turbine, the rate of steam is nearly 4Kg/KWhr.and MAPS turbine steam
rate is nearly 5-6Kg/KWhr.
v Steam consumption per hour at no load is 0.1 to 0.14 times the full load steam
consumption for condensing turbine.
v Throttle Governing
a) It is a simple governing system for Base Load Station.
b) Outlet pressure of the Governor valve is lower than the inlet pressure (but enthalpy
remains the same) and hence steam flow is controlled.
c) Losses in Steam energy and poor turbine efficiency at part load.
v Turbine Losses
The losses in a turbine may be divided into two groups – external and internal.
External losses are due to bearing friction and the power required to drive auxiliaries.
Internal losses are a) Friction losses b) Leakage losses c) Leaving loss
On modern turbines inter-stage leakage accounts for 0.5 to 1.0% loss if the seals are in
good condition.
v Casings or Cylinders
The cylinder has to be extremely stiff in a longitudinal direction in order to prevent
bending and to allow accurate clearance to be maintained between the fixed and moving
parts of the turbine.
The working pressure aspects demand thicker and thicker casing and the temperature
aspects demand thinner and thinner casings. Design developments took place to take
care of both pressure and temperature considerations.
Three types of casing design:
a) Single shell casing, b)Multiple (double) shell casing & c) Barrel type casing
67
v Governor maintains a constant mean speed of rotation of crankshaft as closely as
possible, over long periods during which the load on the engine may vary. It exercises
no control on cyclical fluctuation of speed.
v Flywheel serves to limit the inevitable fluctuations of speed during each cycle that arise
from the fluctuations of turning moment of the crankshaft. It has no effect on the mean
speed of rotation.
v Exhaust Annulus
a) The maximum blade length approximately 30” for 3600rpm shaft and 46” for 1800
rpm shaft. MAPS LP last stages blade length is 37.2”.
b) The length of blade is determining, the flow area for the steam at the exhaust end of
the turbine.
c) The exhaust area and turbine efficiency is interrelated. (i.e.) within certain limits,
when the exhaust area is greater the efficiency will be higher.
The last stage annulus) Generator output KW
area required in inch2) = -------------------------------------------------
(Rough estimation) ) 1000 * Average exhaust pressure inch. Hg. Abs.
v Impulse Turbine
a) The pressure drop takes place at fixed blade/Nozzle.
b) Maximum efficiency of an impulse turbine is obtained when the blade speed is
approximately half the speed of the steam.
Blade Velocity
Velocity Ratio = ---------------- = 0.5 or exactly 0.48
Steam Velocity
v Reaction Turbine
a) The pressure drop takes place both fixed and moving blade.
b) Maximum efficiency in reaction turbine is when the blade velocity is almost equal to
steam velocity.
Velocity Ratio = Around 0.80 to 0.85
c) Since velocity ratio is high, only a small heat drop can be accommodated per
blade row, larger number of stages is required than impulse turbine.
v Compounding
a) The process of reducing the rotor speed by absorbing the energy in several stages
is known as compounding.
b) In pressure compounding turbine, pressure drop takes place equally in the entire
nozzle, the velocity gained at nozzle is subsequently absorbed in the next moving
blades.
c) In Velocity compounding the full pressure drop occurs in the Ist nozzle ring and
pressure remain constant in the moving and fixed blades. The total velocity gained
at 1st nozzle is absorbed in each moving blades.
d) In Pressure & Velocity compounding is a combination of both the previous
methods. Less stage is necessary because of bigger pressure drop in between
stages. Hence for a given pressure drop, the turbine will be shorter and the
68
diameter of the turbine is increased at each stage to allow for the increasing volume
of steam.
MAPS Turbine is Impulse (70%) Reaction (30%) and pressure compounding turbine.
v Twisted Blades
The blade speed will vary from root to tip, the ratio of the blade to steam speed
changes over the length of the blade. Reasons for impulse at bottom of blade and
reaction at top of blade:
a) To accommodate change of velocity ratio.
b) To confine steam moving radially out and to have steam flows parallel to the shaft,
towards the exhaust end.
v Shrouding: The strip of metal joining all blades together at the tips and adds
strength to the blades. It confines the steam within the space of the blades and thus
reduces the leakage.
v Lacing wire to dampen vibration along the blades. The lacing holes are however
a source of weakness and the wires disturb the steam path.
v Turbine Bearings:
a) Lead wire to measure the bearing clearance should not be more than 0.25mm
(0.010") thicker than the estimated bearing clearance.
b) If L/D ratio of Journal bearings is > 0.5 place lead wire at two places on the
Journal along its length.
c) Bearing clearance at the top is equal to the thickness of the wire, on the top of the
journal, minus the average thickness of the lead wire on both sides of the parting
plane.
d) General Thumb Rule of oil clearance of Journal bearings: 0.0375/ 25.4 mm
(1.5Thou/inch.) dia for top clearance and side clearance is half of the top
clearance.
e) The vertical clearance should not exceed 0.0015mm per mm dia. and when
increases to 0.002 /mm per mm dia, the bearing shell should be replaced with a
new one.
f) The minimum thickness of oil film depends upon details of design, but an average
value is approximately ½ thou per inch radius of the shaft. For example, the
minimum film thickness for 18 inch.(MAPS LP Turbine Journal) diameter shaft
would be 4½ thou.
g) The general principle of alignment (assuming the coupling faces to be true with the
shafts) is that, the shafts are aligned in such a way that a continuous curve is formed
69
with their natural deflections from governor to exciter. The shaft will retain their
natural deflection at any speed other than the critical speed.
h) Usual bearing temperature range from 1250F (510C) to 1600F (710C); occasionally
the oil leaves at 1750F (800 C).
i) In barring gear full oil circulation is provided to the bearing to prevent overheat by
conduction from turbine or generator rotor when shutting down since bearing metal
tends to become plastic around 3000 F (1490 C).
v The governor is said to be hunting, when a governor is oversensitive, and the sleeve will
oscillate between two extreme when there is a slightest change of speed.
v All Governor Pins should be just loose and never more than 0.125 mm (0.005").
TRAPS
v Function of Steam Trap is to send out the condensate, air and CO2 from the system
as quickly as they accumulate.
a) Traps must drain condensate because it can reduce heat transfer and cause water
hammer.
b) Traps should evacuate air and non condensable gases as quickly and completely as
possible to increase heat transfer and to reduce the corrosion effect.
70
v Critical Speed: The angular speed at which a rotating become dynamically unstable
with large lateral amplitudes, due to resonance with natural frequencies of lateral
vibration of the shaft.
MAPS TG Rotor combined critical speeds are 650, 1300, 1850 and 2650 rpms.
v Turbovisory Equipment: is necessary to ensure safe and satisfactory operation of the
plant. Deviation of any reading gives advance warning to the operator so that
appropriate action to be taken in time to prevent damage.
a) Differential Axial Expansion detects the axial clearance between moving and
Stationary parts. Rotor expansion relative to the casing gives positive reading, rotor
contraction gives negative reading. If it exceeds the limit, it causes rubbing of moving
blades with fixed blades and rubbing of turbine gland labyrinths.
b) Shaft Eccentricity: Measurement gives warning of a bend shaft especially in low speed.
At a higher speed the same type of information is measured as vibration.
v Gas tightness test(Air holding test) for MAPS Generator: Leakage of gas in 24 hrs.
with respect to atmospheric pressure
v Gas Turbine
a) The range of compression ratio in a gas turbine is 5 to 8.
b) Overall efficiency of a gas turbine is less than Diesel cycle efficiency.
71
PART-B - MECHANICAL GENERAL
v Motion of a machine or machine parts back and forth from its position of rest.
v By knowing the frequency of the vibration, we can identify which part is at fault and
the nature of the problem.
v Where Stress is of major importance at very low frequencies (less than 600 CPM)
displacement measurement is important.
72
v Whenever the amplitude of axial vibration is greater than 1-1/2 times of the highest
radial (horizontal or vertical), then misalignment or a bent shaft should be suspected.
v Faulty anti-friction bearings cause a high frequency vibration, normally several times the
rotating speed of the part but not an even multiple of shaft RPM.
v Problem with sleeve bearings, which result in high levels of vibration or noise.
v Phase is defined as the position of a vibration part at a given instant with reference to a
fixed point or another vibrating part. This is essential (a) in diagnosing specific
machinery defects comparing the relative motion of two or more parts (b) allows us to
balance the part quickly and easily without trial and error techniques.
v Unbalance is the unequal distribution of the weight of a part about its rotating centre line.
v CAUSES OF UNBALANCE:
There are many reasons that unbalance may be present in a rotor. The most common
causes are following:
a) Blow holes in castings, b) ?Eccentricity, c) ?Addition of keys and key-ways
d) Distortion, e) ?Clearance tolerance, f) ?Corrosion and wear, g) ?Deposit built-up.
v Balancing is the technique for determining the amount and location of this heavy spot so
that an equal amount of weight can be removed at this location or an equal amount of
weight added directly opposite.
v Eccentricity is a common source of unbalance and can also result in reaction forces.
v Centrifugal force due to unbalance actually increases by the Square of the rotor RPM
that result as unwanted vibration
v Unit for expressing unbalance is the product of the unbalance weight and its distance
from the rotating centre line (i.e.) grams-centimeters etc.
v For L/D ratios less than 0.5 and operating speed upto 1000 RPM single plane
balancing is sufficient. Above 1000-RPM two plane balancing is often required.
v For L/D ratios greater than 0.5, two-plane balancing is usually required for operating
speed greater than 150 RPM.
73
v Shafts should be designed to operate at a speed that is 20% above or below the critical
speed. Shaft that operates above the critical speed should be balanced under
operating conditions.
v Locate the test transducer as close as possible to the bearing with solid metal between
the bearing and the sensor.
Axial vibration is the best indicator of misalignment or a bent shaft. In general, whenever the
amplitude of axial vibration is greater than one-half of the highest radial (horizontal or
vertical), then misalignment of a bent shaft should be suspected.
Eccentricity does not mean out-of-round, but means that the shaft (rotating) centerline
is not the same as the rotor (geometric) centerline.
74
2. Shock Pulse Measurement
v 15% addition cost is required for break down maintenance without condition
monitoring.
v Using vibration analysis, by the time the bearing vibrate, shows large enough to be
deleted. In many cases, the bearing is closes to failure and provides very little warning
time.
v It detects development of a mechanical shock wave caused by the impact between two
masses at the initial stage.
v It magnifies the weak amplitude and high frequency shock wave and gives out sequence
of electric pulse proportional to the amplitudes of the shock waves.
v Bearing condition is evaluated based on the measured values, LR and HR and the
basic data input prior the measurement.
v Good Bearings will have low HR value and difference between LR and HR (called
the delta value) will be smaller. (about 4).
v Lack of Lubrication (Dry running) will have higher HR value and the delta value will
be smaller at initial stage.
v Rolling interface surface deterioration or damage will have higher HR Value and delta
value will also be larger.
v Cracked inner ring will have low HR value (as if good bearing) and large delta value.
v By measuring the variations in the shock pulse patterns of undamaged bearings, the
SPM evaluate the effect of the lubricant film and display a LUB No., which is directly
proportional to film thickness.
75
3. Material Handling
v EOT Crane:
a) Before taking load on a Crane, ensure condition of limit switches by operating the
crane without load.
b) If a Hook throat is stretched just 15% from original size, or is twisted more than 10
degree, any crack in the hook, do not use it, the hook shall be rejected.
c) A clear space 18” wide must be maintained between any moving part of crane and
any stationary part or object.
d) While operating mobile crane, vertical or lateral distance between any part of the
crane and any overhead power cable must be more than 6 metres.
e) CO2 or DCP extinguishers should be kept in the cabin.
f) Crane load test to be carried out once in twelve months as per the Atomic Energy
Factory (Factories) Rules 1996.
Upto 20 Ton – Test load 25% excess
More than 20T and Upto 50T - 5T Excess
More than 50T - 10% Excess
g) Permissible crane beam centre deflection during load test is L/900,
Where L = Span length.
MAPS T/B Crane 28,000/900 = 31.11mm, S/B Crane 19,500/900 = 21.66mm
h) In Cranes hoist mechanism, (equipped with two brakes) each brake should hold at
least 1½ times the rated capacity of the Crane.
i) Hooks – Forged and heat-treated alloy steel.
j) Limit Switches – One for over hoisting, one for over lowering and one gravity type limit
switch for preventing over hoisting.
k) Major cause of break down in cranes and hoists is vibration, which are caused due to
frequent jerky starts of the whole bulk of the crane/hoist. Vibration hence loosens the
fasteners and connections causes misalignment and break down.
v Synthetic Nylon Ropes: This is strong, roughly 2 times stronger than Manila, has
good abrasion resistance.
v Wire Rope:
a) Improved plow steel - A high Carbon steel with tensile strength of 2, 60,000
PSI. (i) Wire rope for Sling 6 * 19 (ii) Wire rope for Crane 6 * 37 (flexible).
b) When we use 2 wire ropes the included angle should not exceed 90o.
76
c) Increasing the angle between the legs of String increases the stress on each leg of
sling even though the load is same and reduces the lifting capacity.
v Angle between the leg and tension in each leg are as follows:-
90o – 0.707W, 120o – 1W, 150o – 1.93W, 170o – 5.74W, 175o – 11.4W, 178o –
28.65W, 180o – Infinity.
v The wire shall be rejected if any one or more of the following conditions
observed.
a) The number of visible broken wires exceeds 10% of the total wires in a length
equal to 8 dia.
b) Even one broken wire exists below, the metallic socket at the eye of the sling.
c) The dia. of the rope is reduced by wear at any point by 10% of more.
d) Rope is corroded at the base of a metallic socket or at any point.
e) Formation of bird caging, kink, crush or jam.
f) A wire rope becomes unserviceable when 5% or more broken wires are showing
in any of 10 diameters.
v Chain Slings: Chains for material handling equipment’s are generally made of
carbon steel and small chain hooks are generally drop forged.
The chain shall be rejected if any one or more of the following conditions observed.
a) Presence of any crack in welds areas or any other section of the link.
b) Wear of the chain link is 10% of its normal diameter.
c) Stretch or elongation is more than 3% of its length. (Elongation should be
determined by measuring the length of 10 or 20 links).
d) Bent twisted or damaged links and corrosion of chain links.
e) Chains made up of iron of less than 5/16” dia. should not be used for lifting.
v Eye Bolts:
a) The eyebolt should be rejected if any crack or damage of thread, which does not
allow the bolt to screw in fully.
b) Collarless Eyebolts are designed for vertical loads only.
c) The shoulder type eyebolt has an angular strength several times greater than the
conventional eyebolt.
d) Ordinary drop forged steel eyebolt is designed only for vertical load. Shoulder or
Collar type eyebolt hole should have enough depth, about 1.5 times of bolt diameter.
During tightening collar should be in contact with plain surface, if not contacting with
plain surface pack it with washers.
77
Where `d’ is the shank diameter in inches with unaltered eye and threading.
4d 2
Zeroo angle – 4d 2 (app.), 45o = -----, &Over 45o is not recommended.
4
d) Lifting eye must never be altered by such means as grinding, machining or cutting.
e) Ensure Snug seating of the shoulder of the lifting eye. Washer can be used to ensure
lifting eye. Washer can be used to ensure Snug seating as long as there is a 90%
minimum threads engagement.
v The breaking strength divided by the actual total stress on the rope is known as the
“factor of safety” and should not be less than the values given in Table.
v Safe Working Loads: Safe working loads are to be arrived at by dividing the
minimum breaking load quoted by the manufacturer by appropriate factor of safety
depending on the use. Factor of safety as below is recommended in relation to their
diameter:
Dia of rope (mm) 12 14-17 18-23 24-39 40 & above
Factor of Safety 12 10 8 7 6
It is also recommended that fiber ropes less than 12 mm dia should not be used for a
sling or as part of a lifting appliance.
v Lifting Tackles: The load test for newly procured or repaired lifting tackles (except
wire rope) shall be carried out as follows.
a) Upto 25 tons (SWL) - Test load is 2 X SWL Tons
b) Above 25 Tons (SWL) - Test load is (1.22 X SWL) + 20 Tons
Safe load in tonnes for wire rope slings (6 Strands of 19 wires - New improved plough
steel) under different loading condition.
a) Single wire rope sling vertical lift - 6d2 say W tonnes.
b) Sling or 2 Wire Ropes - Used at 120o included angle - W
c) Sling or 2 Wire Ropes - Used at 90o included angle - 1.4 * W
d) Sling or 2 Wire Ropes - Used at 60o angle - 1.73 * W
78
v Noise Control:
a) The TLV of noise level is 90 dB (A).
b) A person can work at 90dBA for 8 hours a day. The time of exposure will be
reduced by 50% for each 5dB (A) increase.
c) No exposure in excess of 115dB (A) is to be permitted.
d) The limit of audibility is 120 dB (A).
e) Properly fitted Earplugs and Earmuffs can reduce the noise level by 30 to 40dB (A).
f) The audible frequency range is 20 to 20000 Hz.
v Forklift:
a) Do not drive at a speed exceeding 28 kmph.
b) Keep the fork about 10-15 cm above the ground while driving.
c) Forklifts should not be moved on ramps or grades exceeding 1 in 10.
v Working at Height
a) For working at height, above 4.5 meters a safety belt should be used.
b) Welders should have safety belt more than 1.5-metre elevation.
c) The belt should be strapped to the upper trunk of the person and the free end
hooked to a fixed structure above.
d) Proper working platform with suitable approach ladder should be provided if any
work has to be carried out at a height of work more than 2.5 metres from the
working floor.
I. Ladder
a) Erect the ladders in the “Four-up-one-out” position (The horizontal distance from the
wall to the foot of the Ladder should be about a Quarter of the Ladder’s length). The
Angle between portable ladders to the ground should not be less than 75o.
b) The ladder length should not exceed the following limit.
Single Ladder - 20ft, Extension ladder - 50 ft.
Step Ladder - 18ft and trestle ladder - 16 ft.
c) Single ladders are used where the work required to be done is at a fixed height. The
length of a single ladder should not be more than 20 feet and the rungs should be placed
12 inches apart. The inside width between the side rails should be at least 111/2 inches
for ladders up to 10 feet length, the width should increase by 1/4 inches for each 2 feet
extension in length.
II. Scaffolding
a) The recommended nominal bore of scaffolding tube is 40mm.
b) The minimum thickness of Scaffolding plank should be 32mm for a span of 1
metre. It is 38mm. for 1.5 metre and 50mm for 2.6 metre.
c) A railing of height 1 metre should be provided above scaffolds.
d) Toe boards of 15 cm height are to be provided to prevent tools and other materials
from falling down and causing injury to people.
e) Where the height is more than 3 times the base dimensions, it should be supported
against overturning.
79
a) Maximum weight an adult male worker allowed to lift is 55 Kg.
b) Maximum weight an adult female worker allowed to lift is 30 Kg.
v Ozone is produced in the air where arc welding is done. It is a toxic gas. The
permissible limit (TLV) of exposure for Ozone is 0.1ppm.
v Grinding
a) Every abrasive wheel should be visually examined for breakage, cracks or any
damage and for expiry date.
b) The distance between the work rest and the wheel should not exceed 3 mm.
c) Safety guard should cover ¾th of the grinding wheel.
d) The wheel should be mounted on its shaft in such a way that the direction of the
thread of the securing nut tend to tighten itself while it revolves.
v Storage of Cylinders :
a) Thin walled cylinders such as LPG and dissolved gas cylinders shall not be
Stacked in horizontal position.
b) The flammability limit of LPG is 3-10%.
c) Use Ammonia torch to detect chlorine leak.
d) Chlorine cylinder Hydro test is to be done once in two years.
e) Since one volume of liquid chlorine when vapourised yield 460 volumes of gas,
hydrostatic rupture in containers, pipelines and other equipments may occur due to
build up of excessive pressure.
v Climbing of Stack
a) Early, in the morning (when Sun is not hot)
b) No strong winds or rains
c) 5 minutes rest after each stage
d) Second person can climb after first person reach the next stage Climbing
down also can follow the same precautions.
v The cutting speed of Hacksaw should not exceed 60 strokes per minute.
v Gap between guard and accessible rotating parts, should be never larger than ½ an
inch.
v Hand injury due to slippage of torsion tool is 25% of total accident in a year.
80
81
4. Hydraulics
v Pascal’s ((French Scientist) Law: Pressure applied on a confined fluid is transmitted
undiminished in all directions and acts with equal force on equal areas and at right angles
to them.
v Hydraulic means transmitting power by pushing on a confined liquid. Input and output
component of the system is called a pump and an actuator.
v Advantages of Hydraulics
a) Variable speed by varying the pump delivery or using a flow control valve.
b) Variable force by varying the pressure using Relief Valve or Pressure Reducing Valve.
c) Reversible. Actuators can be reversed instantly using four way valves.
d) Small packages
e) Can be stalled.
Hydraulic Oil
a) Non-Compressible. It will compress 0.5% at 1000 PSI pressure. It can transmit
power instantaneously.
b) Greek word hydor means “water” and autos means “pipe”.
c) Lubrication ability to the moving parts of the components.
d) Pressure build up is 0.4 PSI/foot of oil column.
82
v Pressure equals the force of the load divided by the piston area
F
(i.e.) P = ---
A
v Speed of an Actuator or motor rotates depends on its size and the rate of oil flow.
Volume/Time
(i.e.) Speed = ---------------
Area
v Velocity in Pipes:
a) General recommended velocity ranges at pump inlet line is 2 to 4 feet/sec. and
outlet/working line is 7 to 20 feet/second.
Note: Very low velocity is recommended for the pump inlet line because very little
pressure drops can be tolerated there.
b) Doubling the inside diameter of a line, Quadruples the crossectional area; thus
the velocity is only one fourth as fast in the larger line.
v A hydraulic device, which uses the impact or kinetic energy in the liquid to transmit
power, is called a hydrodynamic device.
v When a force applied to a confirmed operates the device liquid it is called a hydrostatic
device.
v Daniel Bernoulli’s (Swiss Scientist) principle says that the sum of the pressure
energy and Kinetic energy at various points in a system must be constant if flow rate
is constant.
83
v Four Primary purposes of the Hydraulic fluids
a) To transmit power
b) To lubricate moving parts
c) To seal clearances between parts
d) To cool or dissipate heat
v Absolute Viscosity: Poise viscosity is defined as the force per unit of area
required to move one parallel surface at a speed of one centimeter per second past
another parallel surface separated by a fluid film one centimeter thick.
Unit - Poise, Centipoise Shear stress
Absolute Viscosity = ----------------
Rate of S-bear
84
v SUS (Saybolt Universal Seconds) Viscosity: It is a Relative Viscosity is
determined by timing the flow of a given quantity (60 milliliters) of a fluid through a
standard orifice (0.176 cm. Diameter and 1.223 cm. long) at a given temperature.
(100oF or 210oF). Ordinary, Viscosity tests are made with the oil at a
temperature of 100oF. If more than 1000 seconds would be needed to empty the
container because of thick oil, the oil would be heated to 210oF.
v Pour Point is the lowest temperatures at which a fluid will flow. For a thumb rule,
the power point should be 20oF below the lowest temperature to be encountered.
v Oxidation Resistance
(a) Oxidation or Chemical union with Oxygen is a serious reducer of the service life
of a fluid.
(b) Oxygen readily combines with (petroleum oil) carbon and hydrogen.
(c) Most of the oxidation products are soluble in the oil and additional reactions take
place in the products to form gum, sludge and varnish which plug orifices, increase
wear and cause valves to stick.
d) When the maximum temperature of hydraulic system exceeds 150oF (65oC) oil
oxidizes. The rate of oxidation approximately doubles with every 18oF (10oC)
increase in temperature according to the characteristics of the fluid. Some fluid
power research indicates that the working life of most oil is decreased by 50% for
every 15oF rise in temperature above 140oF (60oC). Oxidation causes sludge to
form, reduce clearance, creates more heat and causes corrosion.
v Most of the Petroleum products (Hydro carbons) are approximately 85% Carbon
and 15% hydrogen. The difference between the products is determined by the size
of the molecules and the arrangement of the atoms in those molecules.
v Synthetic fluids are not compatible with the commonly used Nitrile (Buna) and
Neoprene seals.
85
v Pressure and Flow Considerations
a) Industry Standard recommended safety factors:
b) Nomographic Chart can be used to select the pipe/tube internal size if the
velocity and flow rate is known.
G.P.M * 0.3208
Area (Sq. inch) = ---------------------
Velocity (ft/sec.)
v Seal Materials
a) Natural rubber is seldom used as a sealing material because it swells and deteriorates
in the presence of oil.
b) Synthetic rubbers (elastomers) are quite compatible with oil.
Buna-N retains sealing properties from 40o to 230oF. It does swell in some synthetic
fluids.
Viton for high temperature oil.
Neoprene: Above 150oF neoprene is unsuitable as a sealing material because of
a tendency to vulcanize or “Cook”.
c) Silicone
It retains its shape and sealing ability to –60oF and is generally satisfactory upto 400
to 500oF.
At high temperature it tends to absorb oil and swell. This however, is no particular
disadvantage in static application.
Silicone is not used in reciprocating seals, because it tears and abrades too easily.
v Functions of Reservoirs
a) Store house for the fluid until called for by the system.
b) Place for air to separate out of the fluid.
c) Permit contaminants to settle out.
d) Dissipate any heat that is generated in the system.
e) When filling the hydraulic oil into the system, a filter of less than 60µm(less than 220
mesh) should be used.
v Baffle Plate
a) Height of the Baffle plates is usually 2/3 of the height of oil level.
b) Prevent local turbulence in the tank.
86
c) Allows foreign material to settle to the bottom.
d) Gives the fluid on opportunity to get rid of entrapped air.
e) Helps to increase heat dissipation through the tank walls.
v The pump suction strainer should be will below the normal fluid level in the tank
and at least 1 inch. from the bottom.
v Hose Installation: Six basic rules of thumb to use when installing hose are:
a) Make it big (diameter)
b) Make it long (generous, no tension)
c) Never exceed the minimum bend radius
d) Never install a twisted hose. (A slight twist in a hose can reduce its life by 70%).
e) Protect hose lines that pass close to a heat exhaust manifold with a fire proof
boot or a metal baffle.
f) Always use proper fittings
v It holds particles of dirt and other foreign matter, which have abrasive effect causing
damage through excessive wear.
v Function of Accumulator:
Act as an energy storage device, shock absorbers and pressure surge dampeners.
v Recommended Reservoir Capacity is three times the flow rate in gallons per minute.
v Square or a rectangular tank has the largest heat transfer surface per unit volume.
87
v Reservoir should contain additional space equal to at least 10% of its fluid capacity for
thermal expansion of the fluid, gravity drain back during shutdown and still provides a free
fluid surface for air separation.
v Hydraulic fluid, which is normally mineral oil, usually has a specific gravity between 0.8
and 0.9, which means that its weight between 80 and 90% that of water.
v Horse Power (a measure of the rate of work) involves three factors. Force, distance and
time (in hydraulics. Flow pressure and time).
v 1 HP = 1 gpm at 1500 PSI (approx.) (1hp moves 33,000 lbs to the distance of 1ft in 1
min.)
1 HP = gpm * pressure * 0.00058 (100% efficiency)
1 HP = gpm * Pressure * 0.0007(85% efficiency)
d) Pump and Cylinder systems: 15 to 25% of input hp goes to heat, plus any heat
restriction. Heat of restriction: gpm * psi (drop across restriction) * 0.00058
equals the amount of horse power going directly into heat.
v To find the capacity of a cooler when oil temperature drop across cooler and gpm
are known.
gpm * temperature drop * 210 = Btu/hour capacity
88
5. Engineering Materials
v Ferrous Materials: Those containing iron as principal constituent e.g., cast iron,
wrought iron and various types of steels.
v Elastic Limit: It is the greatest stress a material can withstand without permanent
elongates when the load is removed the sample will return to its original length.
v Yield Point: The stress at which appreciable elongation occurs without increase in
stress.
v Modules of Elasticity: It is the ratio of stress to strain within the elastic limit. It is
a measure of stiffness.
v Elongation: It is the ratio of the increase in gauge length to the original gauge
length expressed in percentage.
v Ultimate Strain: The unit elongation (elongation per unit of length) at the specimen
breaking point. It is a measure of ductility.
v Poisson’s ratio: It is the ratio of the transverse to the longitudinal elastic strain in an
axial member, loaded on its longitudinal axis.
89
v Stiffness: It refers to the ability of a metal to resist bending stretching, shortening and
twisting. It is defined by the Modulus of elasticity. The modulus applies only within the
elastic range-the range within which a metal will return to its original shape if the load is
removed, it is the ratio of stress to strain.
v Transverse Shear Strength: The value obtained by dividing the breaking load by the
transverse shear area. It is needed in the design of rivets, bolts, pin and other such
components.
v Torsion: The twisting of materials by force, which turns one end of a bar about its
longitudinal axis while the other end, is either clamped in a rigid fixture or twisted in the
opposite directions.
v The corrosion rate of metals typically doubles with each 10oC increase in temperature.
v Stress Corrosion Cracking (SCC): Failure by cracking under the conjoint action of
a constant tensile stress, which is applied to residual, in certain chemical environments
specific to the metal.
v Stress Relief Cracking: Cracking between metal grains in the heat affected zone of a
weldment during the exposure to high temperatures.
90
v Creep: When a material is subjected to internal load within elastic limit at elevated
temperature for a prolonged duration, a permanent set occurs. This progressive
deformation of material is known as creep.
v EN (Emergency Number) Series Steels are coming under medium carbon steel range.
Can be hardened by heat treatment.
Weight of metal:
a) 7.85 grams/cc or 7.85 Kg/Sq. Mtr./1mm thick for carbon steel.
b) 40.833 lbs/Sq.foot of plate/1 inch. thick.
c) 7.97 grams/cc for stainless steel.
v Abrasives used for surface finishing and its size is given as grit size. Artificial
abrasives are silicon carbide, aluminium oxide, and boron carbide or boron nitride. Fine
Aluminium oxide in powder with smaller particle 0.5micron or 0.0000197 inch. is used
for fine finishing of surface.
v Admiralty Brass: It contains 71% Copper, 0.75% tin and 28% Zinc. Tin (additional
corrosion resistance) increases the hardness and strength but decreases the ductility.
Used in MAPS LP Heater’s tubes.
v Bronze: It contains 70 to 85% Copper, 5 to 10% tin and 5 to 25% lead with Zinc
below 0.50% (ASTM bearing bronze).
v Brass: It contains 70% Copper, 0.4% Arsenic and remainder is Zinc about 30%.
91
At MAPS - Used in boiler tubes. It is a chemical stability material and its melting point
is 1500oC.
v Zirconium Alloys generally have only small amount of alloying elements. To add
strength and resist the pick up of Hydrogen.
MECHANICAL PROPERTIES
v Tensile Strength: This is the ability of a material to withstand tensile (stretching) loads
without rupture occurring. The material is in tension.
v Shear Strength: This is the ability of a material to withstand offset or transverse loads
without rupture occurring. The river connecting the two bars shown is in shear whilst
the bars themselves are in tension. Note that the river would still be in shear if the bars
were in compression.
92
v Elasticity: This is the ability of a material to deform under load and return to its original
size and shape when the load is removed. Such a material would be required to make
the spring shown.
v Plasticity: This property is the exact opposite of elasticity. It is the state of a material,
which has been loaded beyond its elastic state. Under a load beyond that required to
cause elastic deformation (the elastic limit) a material possessing the property of
plasticity deforms permanently. It takes a permanent set and will not recover when the
load is removed.
v Ductility: This is the term used when plastic deformation occurs as a result of applying
a tensile load. A ductile material combines the properties of plasticity and tenacity
(tensile strength) so that it can be stretched or drawn to shape and will retain that shape
when the deforming force is removed. For example, in wire drawing the wire is
reduced in diameter by drawing it through a die.
v Malleability: This is the term used when plastic deformation occurs as the result of
applying a compressive load. A malleable material combines the properties of plasticity
and compressibility. So that it can be squeezed to shape by such processes as forging,
rolling and river heading.
Processes, which increase the hardness of material, also increase their tensile
strength. At the same time the toughness of the material is reduced as it becomes more
brittle.
Harden ability must not be confused with hardness. Harden ability is the ability of a
metal to respond to the heat treatment process of quench hardening. To harden it, the hot
metal must be chilled at a rate in excess of its critical cooling rate. Since any material cools
more quickly at the surface than at the center there is a limit to the size of bar which can
cool quickly enough as its center to achieve uniform hardness throughout, this is the ruling
section for the material. The greater its harden ability the greater will be its ruling section.
93
6. Surface Finish and Flatness
Surface Finish
Roughness
Grade symbol ∞ ∇ ∇∇ ∇∇∇ ∇∇∇∇
Roughness valves
Ra µm 25-50 8 – 25 1.6 – 8 0.025 - 1.6 Less than 0.025
Flatness: All the points on the surface are lieing in the same plane.
a) Concentric serrated grooves 1/16” deep and 32 serration/inch for CAF gasket.
b) 80 micro inch is always preferable and 150 to 200 micro inch also acceptable for a
Metallic gasket.
94
7. Hardness Testing
v Brinnel hardness number (BHN), the ball size is 10mm for most cases or 1mm for light
work.
Load
BHN = ------------------------------------------
Spherical area of the indentation
a) The tensile strength of a metal in pounds per square inch. is 500 times its brinell hardness.
b) The Brinell and Vickers hardness values are practically identical upto a hardness of 300.
c) In Brinell hardness the testing time of loading is 15 seconds.
v Vicker’s pyramid method, which utilises a pyramidal point. (Pyramid indentor apex is
40o.
v Shore Scleroscope measures the height of rebound of a hammer falling on the surface.
v Shore durometer
v Hardness of antifriction bearing
i) Inner and Outer race is 55 - 58 HRC
ii) Rolling element is 58 - 63 HRC.
95
8. Mechanical Fasteners
v Surfaces are often serrated to achieve biting effect on the gasket, so that there is better
confidence of the deformation of the gasket.
v The strain of the deformation of the gasket is often beyond the elastic limit. So, a gasket
is advocated to be considered as one-time use component.
Sequence of tightening the fasteners helps ensure that the
a) Surfaces are moved towards each other with proper orientation and location.
b) The fasteners share equal load.
c) Gaskets do not loose its flexibility.
v Mark or scribe a diagonal line down the side before the equipment is disassembled. It
helps to align the line during reassembly to ensure the components are in proper
sequence.
v Always Bolt and nut threads are to be lubricated to reduce friction between the
threads and nut to washer so that maximum preload can be achieved.
v Repeated unscrewing and tightening of steel nuts score threads. After 50 tightening, the
torsional resistance is approximately 100% greater than for the first tightening. After
200 tightening it is approximately 156% greater.
v Hexagonal head Flat to Flat is 1.5 times and Corner-to-Corner is 1.7 times of bolt size.
v Socket head bolts are made of high tensile steel, head thickness is 1d and the dia. of
head is 1.6d when d is the out side or major diameter of thread.
v Thickness of standard nut required is 0.8d and thickness of thin nut is 0.5d.
Thickness of plain washer is 0.15d.
v The strength of fine threads of tapped hole is greater for sizes 1 inch and under. Strength
increases as the size decreases.
v A Coarse thread is desirable where the hole is tapped in weaker materials, for example,
Cast iron, Aluminium and Magnesium alloys. It is stronger in size 1 inch. and over.
v A higher bolt pre-load will lower the effect of the cyclic load on the total bolt load.
v As a rule, the cyclic load in the bolt should be less than 25% of its yield strength.
v The tightening of bolt should be followed as per bolt tightening sequence and should be
tightened in four steps, hand type, 1/3 torque, 2/3 torque and full torque.
96
v Use torque wrench to ensure proper torque
v Residual gasket load becomes zero for self-energizing type seals since value of `m'
factor is zero.
v Commonly used gaskets are identified and their compatibility to different fluids and
pressure temperature ratings are given in Table-1.
v Generally non metallic gaskets should not be considered above 555oC (850oF) and
below 18oC (65oF) or pressure in excess of 85 Kg/cm2 (1200 PSI).
v Gasket material (have enough mechanical strength) is selected to withstand the pressure
and temperature of the fluid based. Refer Table-II for dimension less number.
v Basically, the criteria fro proper gasket selection can be referred to as TAMP:
Temperature, Application, Media and Pressure.
v `Y’ factor is the minimum gasket seating stress (varies with material, thickness, density
and gasket type) is required to flow the gasket into the flange surfaces. `Y' factor for
different material and required surface conditions are given in Table-IV.
v `m’ factor is the ratio between the residual loads on gasket area to the internal pressure.
`m' factor for different material is given in Table-VII.
v Nut factor is an experimental constant used to evaluate or describe the ratio between
the torque applied to a fastener and preload achieved. Table-VI lists nut factors for
various lubricants.
v The torque value varies around 30% depending upon the cleanliness and lubrication of
the fasteners. Hence gasket manufacturers specify the compression of gasket rather
than to the torque applied on bolts.
a) Spiral wound metallic gaskets can be compressed to 24% to 28% of its original
thickness. Recommended gasket compression for spiral wound gasket is given in
Table-III.
b) C.A.F joints can be compressed to 15 to 20% for getting a flow of gaskets for a 600
/1500 rating flange joints.
97
v For torque values up to 125 lb-ft tighten the joint with a minimum of four tensioning
passes and over 125 lb-ft, use good mechanics judgment to increase a number of
additional tensioning passes to avoid over compression of the gasket.
v Nuts are normally of softer material than the bolts. This ensures plastic yielding which
enables the nut thread to divide the load more evenly.
v There is no strength grading system for small screws (< 1/4 inches.). Care must be
exercised when selecting pre load and torque.
Torque:
98
9. BOLTING OF FLANGE JOINTS
v PRELOAD is the tension force developed in the fastener when it is tightened against
the joint.
v Prying: External tension loads on a fastener are magnified by a lever action called
prying when the line of action of the external load does not lie along the axis of the
fastener.
v Thread stripping is an insidious type of failure. It starts at the stressed thread and
gradually, the remaining threads “peel off” through the entire length of engagement.
v ELASTIC INTERACTION is the process in which the previously tightened bolt will
relax somewhat when its neighbors in the joint are subsequently tightened is called
elastic interaction.
99
v FLANGE ROTATION is the outer edges of a raised face flange are pulled towards
each other when the bolts are tightened. This distortion is called flange rotation.
v POINTS TO REMEMBER:
100
10. Pressure Vessel Testing
v Range of pressure gauge for leak test/pressure test 1.5 times to 4 times of test pressure.
v To find leak in a gas service flange: Wrap a 2” wide marking tape around the flange;
pack a pin hole in the centre of the tape and apply soap water solution. If bubble or
foam appears, the flange is leaking.
101
11. Sealants
-Parts by Weight -
Hardener HY 830 45 50 30
(Slow Curing)
Hardener Hy 850 15 10 30
(Accelerated)
Total quantity of two hardeners should be 60 parts per 100 parts of ARALDITE GY
250.
Hy 840 - 50 “
*******
102
12. Welding
v Gas welding the heat produced melts the metal parts to be welded.
a) Oxyacetylene a flame temperature about 3300oC melts the metals, which fuse together
to form a strong joint. Extra metal may be supplied from a filler rod and a flux may be
used to prevent oxidation.
b) Keep Acetylene pressure less than 15 psi, so that the acetylene mixture does not flow
back into oxygen cylinder.
c) In case of flame flash back, shut off the blow pipe oxygen valve first, then close
acetylene valve.
d) Stainless steel (Chromium Oxide Lever has the higher melting point - 5500oC) can be
cut by which has high flame temperature (more than 10000oC).
e) Capacity and pressure of Oxygen cylinder.
Capacity Pressure
O2 = 6.9m (244 ft ) - 100 Kg/cm 2
3 3
v In Arc welding, the heat of fusion is generated by an electric arc (regulated low voltage
high current) struck between work pieces and welding rod.
a) Bevel angle 37-1/2o (included angle 75o +5o) for C.S pipes
b) Bevel angle 30o (included angle 60o +5o) for S.S pipes
c) Root gap 1.5mm for socket weld joint
d) While grinding SS pipe, Silicon Carbide wheels should not be used.
e) Weaving length should not exceed 3 times the dia of electrode.
v Welding Current
a) 1 Amps for 1 thou dia of electrode
b) The thumb rule of minimum and maximum current (amps) is 40 times and 60 times of
Electrode dia. in mm.
103
v Socket Welding:
a) Socket weld ends are generally used up to 2” dia. and butt weld ends for larger
sizes.
b) Socket weld connections are easily made up with less skill than for butt welds.
c) Failure to leave a small space when welding will produce very high stresses. When the
weld metal contracts and pulls the pipe into the socket which leads to failure of weld
joint and or can distort the seat of gate valve, so that they will not seat properly in
service.
v Procedure qualifications are to demonstrate that the methods and practices used by a
manufacture or contractor for a given material will result in satisfactory welds.
v Welding procedure: Offset of the pipe should not be more than 20% of the pipe
thickness.
v Preheating is desirable if the carbon content exceeds 0.35%, for pipe wall thicknesses
¾ inch. or over, or for alloy material. Preheats of 400 to 450 F for carbon steel, or
500F or higher for alloy material, are normally used.
v Stress relief is mandatory for wall thicknesses of ¾ inch. or greater for ordinary carbon
steels; and for thicknesses of 1/2 inch. and greater if carbon exceeds 0.35%, or for
alloy steels. It is accomplished by slowly heating to the required temperature, holding
that temperature for one hour per inch of wall thickness, and cooling slowly. Stress-
relief temperatures used are 1100 to 1250 F for carbon steel, 1250 to 1325 F for
carbon –molybdenum steel, and 1300 to 1350 F for chromium-molybdenum steel.
104
13. Lapping & Scraping
LAPPING:
v The purpose of lapping is to secure a very smooth surface of a hermetic joint to achieve
leak tightness.
a) For rough lapping, plates or Laps with longitudinal and transverse grooves are
used. The grooves help in collecting excessive abrasive. These grooves are 1-2 mm
deep and are spaced 10-15 mm from one another
b) For fine lapping, a lap with an uninterrupted surface is used.
c) Fine lapping reduces the surface irregularities to as little as 0.6-1.6 microns
d) Extra fine lapping reduces the surface irregularities to as little as 0.16 – 0.4
micron. (1 micron = 0.001 mm).
v A number representing the size of its abrasive particles expresses the grain size of
abrasive. The number corresponds to the mesh per inch of length of the screen, through
which the particles will pass but be retained by the standard screen of finer size.
v Following table gives an idea about comparison of Grit size, grain size:
GRIT SIZE AVERAGE MICRON SIZE DESCRIPTION
220 60 COARSE
320 31 MEDIUM COARSE
400 22 MEDIUM
600 16 FINE
900 9 POLISH
v Lubricant is used, according to the material of the particular lap. For cast iron laps,
benzine or kerosene is used, for steel laps machine oil, for copper laps alcohol, soda
solution or machine oil. For laps made from copper-base alloys use is also made of
machine oil mixed with an animal fat. The selected lubricant is very intimately mixed with
abrasive powder to obtain a homogeneous mixture.
v Principle of LAPMASTER:
The lapmaster is a versatile precision machine engineered to production lap flat surfaced
within tolerances of one light band (0.0000116”) or finishes of less than 2 to 3 RMS micro
inches with absolute uniformity.
105
a) A heavy cast alloy lap plates revolves slowly under power.
b) Large cast alloy adjustable conditioning rings are held in position and rotate freely on the
lap plate to continually keep the plate flat and true.
c) Work pieces may be placed inside the conditioning rings where they also rotate on the
lap to create a cutting action, which forms a true flat surface.
d) Fresh, sharp abrasive grains, suspended in suitable vehicle, are continuously fed on the
lap plate and uniformly distributed under the work pieces during the lapping action.
v MONO-CHROMATIC CHECKLIGHT:
a) An optical instrument known as “Monochromatic Checklight” is used to measure surface
flatness, the measurement unit being ‘Light bands’. It is the most accurate method of
checking flatness and surface flatness up to 1 light band (i.e. 0.0000116” or 0.0002794
mm.) can be easily determined.
b) It is an electrical instrument and operates on 230 V AC domestic supplies. The head of
the instrument contains a vapor filled tube light. The tube is protected by an opalescent glass
plate having a black line marked on it to work as reference during measurement. A platform
is set below the light source and is used to keep the objects for flatness measurement.
c) When switched ON, a little time lapse is required for the light to give full illumination. It
gives a bright light of single “Yellowish- orange” color; all other colors of light get eliminated.
Wavelength of light from this source is 23.2 millionth of an Inch. However since only half the
wavelength is used in the measurement process, the increment measure is one half of 23.2
or 11.6 millionth of an Inch.
v OPTICAL FLATS:
Optical flats are used to measure surface flatness with help of Mono-chromatic checklight.
They are made of fused Quartz; they have perfectly flat and parallel surfaces, have high
resistance to abrasion and are superior due to their very low thermal expansion. For
satisfactory service life the optical flats should be handled very carefully and kept clean.
106
SCRAPING:
v Scraping is a process of surface finishing by which very thin layers of metal are removed
to improve sliding and guide surfaces with least possible friction loss in assemblies and
the maximum possible closeness of fit.
v In fine scraping, metal only 0.01 mm thick is removed in one pass of the scraper.
v In case of sliding contact bearings and other load bearing surfaces a minimum surface
contact of 80% is essential.
v Depending on the purpose a part serves, the quality of scraping is judged by the number
of spots seen when a checking frames with in the space of 25x25mm.
For example:
a) Parts of metal cutting machines (beds, tables, carriages, tool slides etc.) should have 8-
16 spots,
b) Test plates and rules 20-25 spots,
c) Measuring tools and instruments 25-30 spots, etc.
d) A minimum of 80% contact is essential in Plain bearings and split housing of rolling
element bearings.
e) In case of sliding contact bearings and other load bearing surfaces a minimum surface
contact of 80% is essential.
v Scrapers are made of carbon tool steel. The cutting point of the scraper is hardened
without tempering to a hardness of Rc= 60-65.
Scrapers can be classified according to:
a) ?No. of cutting ends: Single-ended and double-ended scrapers
b) ?Shape of cutting edge: Flat, Three-square (Triangular) and Shaped (curved, hook bent
end etc.) scrapers
c) Design: Solid or Inserted tips. Single-ended scrapers are provided with handles, double-
ended scrapers have no handles.
107
14 .PRINCIPLES OF FILTRATION
1. Introduction: Filtration is the separation of particles from a fluid (liquid or gas) by passage
of that fluid through a permeable medium. When the particles represent a significant
proportion of the fluid, the process may be described as bulk solids collection. When the
particles represent only a very small proportion of the total (0.015 or less), the process is
called fluid clarification
2. Filtration Processes: Suspended solids are separated from fluids via three mechanisms;
inertial impaction, diffusional interception and direct interception.
3. Inertial Impaction: Particles in a fluid stream have mass and velocity hence have a
momentum associated with them. As the liquid and entrained particles pass through filter
media, the liquid stream will take the path of least resistance to flow and will be diverted
around the fiber. The particles, because of their momentum, tend to travel in a straight line
and as a result, those particles located at or near the centre of the flow line will strike or
impact upon the fiber and be removed.
4. Diffusional Interception: For particles that are extremely small (i.e. those with very little
mass), separation can result from diffusional interception. In this process, particles are in
collision with the fluid molecules. These frequent collisions cause the suspended particles to
move in a random fashion around the fluid flow lines. Such movement, which can be
observed microscopically, is called “Brownian Motion”. Brownian motion causes these
smaller particles to deviate from the fluid flow lines and hence increase the likelihood of their
striking the fiber surface and being removed.
5. Direct Interception: While inertial impaction and diffusional interception are not as
effective in liquid service as in gas service, direct interception is equally as effective in both
and is the desired mechanism for separating particles from liquids. In a filter medium, one
observes not a single fiber, but rather an assembly of a large number of such filters. These
fires define openings through which the fluid passes. If the particles in the fluid are larger
than the pores or openings in the filter medium, they will be removed at a result of direct
interception by the holes.
a) Electrostatic Deposition:
Most particles carry a negative charge. Filter media often carry charges
that can affect both particle removal efficiency and for particle retention efficiency of
the filter. It is possible therefore to enhance the particle capture mechanisms of a
filter by inducing a desired charge (usually positive) on the fiber.
b) Flocculation:
108
Very fine size particles are difficult to filter. One way to enhance filterability
is to cause them to flocculate into larger particles that are easier to filter and usually
produce filter cakes within result in less pressure drop and, in consequence, an
increase in throughout.
7. Filter Types: In recent years it has become increasingly common to classify filters and
filter media “depth type” or “surface type”.
Characteristics of Filter:
Among the more important factors it must be taken into consideration when
choosing a filter for a particular application are the size, shape and hardness of the
particles to be removed, the quantity of the particles, the nature and volume of fluid to be
filtered, the rate at which the fluid flows, whether flow is steady, variable and/or intermittent
system pressure and whether that pressure, compatibility of the medium with the fluid, fluid
temperature, properties of the fluid, space available for particle collection, and the degree
of filtration required.
109
15.RELIABILITY, MAINTANABILITY AND AVAILABILITY
Reliability: Reliability of a unit (or product) is the probability that the unit performs its
intended function adequately for a given period of time under the stated operating conditions
or environment. Reliability is always a function of time.
Reliability Parameters
Failure rate: Failure may be defined as the termination of the ability of an item to perform
its required function. Failure rate is expressed as failures for the given time. A lower failure
rate is indicative of higher reliability.
Mean time between failures: MTBF is a basic measure of reliability for an item. MTBF
is the total time that an item is designed to last (or) the total operating time in a given period
divided by the number of failures that have occurred. This parameter is known as the mean
time between failures, or MTBF.
Mean time to fail (MTTF): MTTF is the mean operating time between successive failures.
Mean time to Repair (MTTR) : MTTR is the mean Repair time between successive
operation.
Inherent Reliability: The probability that a device will perform its specified function,
determined on the basis of a statistical analysis of failure rates and other characteristics of
the parts and components which comprise the device. Inherent Reliability is a function of
Equipment, Design and Manufacture.
Use Reliability: The probability that a device of known inherent reliability will perform its
prescribed mission for a specified time when subjected to field human engineering factors
110
and maintenance practices. It depends on equipment operation, maintenance and
environment.
Operational Reliability: The probability that a device of known inherent and use reliability
will perform its mission for the required time when utilized in the manner and for the
purpose intended. Operational reliability is the reliability obtained under actual working
conditions and is obtained as a product of inherent and uses reliability.
Reliability of a System
• Redundancy
• Diversity
• Independence
• Periodic Testing
• Fail Safe Systems
• Reporting to AERB
********
111
LIST OF TABLES
TABLE-1
COMPATIBILITY AND PRESSURE TEMPERATURE RATING OF
COMMONLY USED GASKETS AND ELASTOMERS
112
TABLE-II
A typical thumb rule is used in the form of a multiplication factor for limitation of gasket material
as per table below.
TABLE-III
-----------------------------------------------------------------------------------------------------------------------------
Nominal thickness Compressed thickness
------------------------------------------------------------------------------------------------------------
3.2 mm (.125 inch) 2.4/2.6 mm (.095/.105 inch)
4.5 mm (.175 inch) 3.2/3.4 mm (.125/.135 inch)
6.4 mm (.250 inch) 4.6/4.8 mm (.180/.190 inch)
7.3 mm (.285 inch) 4.7/4.9 mm (.185/.195 inch)
113
MINIMUM GASKET SEATING STRESS – IV
114
TABLE - V
The torque or turning effort required to produce a certain stress in bolting is depending
upon a number of conditions, some of which are:
Diameter of bolt
Type and number of threads on bolt.
Material of bolt.
Condition of nut bearing surfaces.
Lubrication of bolt threads and nut bearing surfaces.
The tables below reflect the results of many tests to determine the relation between torque and
bolt stress values are based on steel bolting well lubricated with a heavy graphite and oil
mixture.
It was found that a non-lubricated bolt has an efficiency of about 50 percent of well-lubricated
bolt and also that different lubricants produce results varying between the limits of 50 and
100 percent of the tabulated stress figures.
Load in pounds on bolts and stud bolts when Torque loads are applied
Data for use with machine bolts and cold rolled steel stud bolts.
115
DATA FOR USE WITH ALLOY STEEL STUD BOLTS
Nominal No. of Diameter Area Stress
Diameter Threads root of at ------------------------------------------------------- --
of bolts per inch thread Root 30,000 psi 45,000 psi 60,000 psi.
116
Table – VI – NUT FACTOR
Reported Nut Factors for Various Materials and Lubricants
Metal/Lubricant Minimum Nut Mean Nut Maximum Nut
Factor Factor Factor
As Received Alloy or 0.158 0.2 0.267
Mild Steel Fasteners
As Received Stainless - 0.3 -
Steel Fasteners
Cadmium Plate (Dry) 0.106 0.2 0.328
Copper Based Anti - 0.08 0.132 0.23
Seize
Cadmium Plate (Waxed) 0.17 0.187 0.198
Fel-Pro C54 0.08 0.132 0.23
Fel-Pro C670 0.08 0.095 0.15
Fel-Pro N 5000 0.13 0.15 0.27
(Paste)
Machine Oil 0.10 0.21 0.225
Moly Paste or Grease 0.10 0.13 0.18
Never-Seize (Paste) 0.11 0.17 0.21
Neolube 0.14 0.18 0.20
Phos-oil 0.15 0.19 0.23
Solid Film PTFE 0.09 0.12 0.16
Zinc Plate (Waxed) 0.071 0.228 0.52
Zinc Plate (Dry) 0.075 0.295 0.53
117
TABLE-VII
GASKET FACTOR (m) FOR OPERATING CONDITIONS
118
TABLE-VIII
NOMENCLATURE OF MESH
119
TABLE-IX
120
THREADING TAPS
v Tap drill Size: a) (Size of the tap in inch * 7/8) – 1/32. b) D - 1.1328P (For with worth threads), c) Size of tap in
mm – (1.23 * pitch), d) “Rule of thumb” = Outside diameter * 0.8.
v English tap drill: Subtract the inverse of the pitch, (in threads/inch) from the bolt diameter. The
number is close enough, with in 0.006 inch. e.g., bolt diameter is 0.500” and thread pitch is 13 TPI.
The calculated Tap-Drill Diameter is 0.500 - 0.077 = 0.313 i.e., 5/16”.
v The required length of a tapped hole depends upon the material. Length of threaded bolt portion = CD inch.
Where C = 1.0 for steel, 1.5 for cast iron, 2.0 for bronze and aluminium. D = Dia. of Stud/Bolt.
TOP - Figures indicate T.P.I
BOTTOM - Figures indicate Tapping Drill Size in MM
BSF BSP UNC UNF N BA 47.5 deg. METRIC 60
SIZE BSW 55 55 60 60 P deg.
deg. deg. deg. deg. T SIZE TPI SIZE PITCH
55deg. 60 (mm) (mm)
deg.
121
5.10
7/8” 9.00 11.00 - 9.00 14.00 - - - 22.00 2.50
19.25 19.75 - 19.50 20.40 - - - - 19.50
1” 8.00 10.00 11.00 8.00 12.00 11.50 - - 24.00 3.00
22.00 22.75 30.75 22.25 23.25 31.00 - - - 21.00
v The thread form (using tap) more than 60% does not increase the strength significantly. Normally 55% to 75% is
sufficient. Generally Table recommends tap drill usually 75% thread height.
UNS
Type Number C Mn Si Cr Ni P S Other
Austenitic Types
201 S20100 0.15 5.5-7.5 1.00 16.0-18.0 3.5-5.5 0.06 0.03 0.25 N
304 S30400 0.08 2.00 1.00 18.0-20.0 8.0-10.5 0.045 0.03 -
304L S30403 0.03 2.00 1.00 18.0-20.0 8.0-12.0 0.045 0.03 -
310 S31000 0.25 2.00 1.50 24.0-26.0 19.0-22.0 0.045 0.03 -
316 S31600 0.08 2.00 1.00 16.0-18.0 10.0-14.0 0.045 0.03 -
347 S34700 0.08 2.00 1.00 17.0-19.0 9.0-13.0 0.045 0.03 (3.0-2.0 Mo)
10X%c
min Nb+Ta
Ferritic Types
450 S40500 0.045 1.00 1.00 11.5-14.5 - 0.04 0.03 0.1-0.3 A1
430 S43000 0.12 1.25 1.00 16.0-18.0 - 0.04 0.03 -
Martensitic Types
410 S41000 0.15 1.00 1.00 11.5-13.0 - 0.04 0.03 -
420 S42000 0.15 1.00 1.00 12.0-14.0 - 0.04 0.03 -
431 S43100 0.20 1.00 1.00 15.0-17.0 1.25-2.50 0.04 0.03 -
Precipitation Hardening Types
17- S17400 0.07 1.00 1.00 15.5-17.5 3.0-6.0 0.04 0.03 3.0-5.0 cu;0.15-
4PH 0.45 (Nb+Ta)
0.75-1.5Al
17- S17700 0.09 1.00 1.00 16.0-18.0 6.5-7.75 0.04 0.03
4PH
122
410 X X
420 X
431 X X X X
Precipitation hardening Stainless Steels
17-4PH X X X X X
17-7PH X X X X X
An “x” notation indicates that the specific type is resistant to the corrosive environment.
Adopted from ASM Metals Handbook Vo.3, 9th Edition (40)
123
References
2. Mechanical Engineer’s Hand Book Second edition, Edited by Myer Kutz, Myer
Kutz Associates inc.
Eugene A. A. Vallone.
Theodore Baumeister 111
MCGRAW – HILL International Editions
6. Vibration and Shock pulse measurements Training Manual 146 NTC, MAPS
10. Major Process Equipment Maintenance and repair. Heinz P. Bloch. Fred K.
Geitner.
15. Mechanical Engineer’s Data Hand Book, J. Carvill, Reed Educational and
Professional Publishing Ltd. 1993.
*******
124