LMTD Correction Factor Charts Page 1
∆TI − ∆TII
LMTD =
ln (∆TI / ∆TII ) ----------- (2)
Here ∆TI and ∆TII are temperature differences between two fluids at each
end of a counterflow exchanger.
T1,o − T1,i
P1 = ------------ (4)
T2,i − T1,i
www.ChemSOF.com
LMTD Correction Factor Charts Page 2
F = Φ1 ( P1 , R1 )
Solution
Area = Q / ( U x F x LMTD )
= 5x106 / ( 80 x 0.9149 x 64.87 )
= 1053 ft2