Series
Output +5VSB 4A +5VSB 2.5A +5VSB 2.5A +5VSB 2.5A +5V 3.0A +5VSB 0.05A
FSP112-3F02(112W)
FSP112-3F02
2.7A
2.5A
+12V +24V
FSP139-3F01(139W)
FSP139-3F01
25
1.5A
4.5A
+12V +24V +5.1VSB FSP146-3M01(146W) FSP146-3M01 146W 260 225 15 3.5A +5V FSP175-4F01(175W) FSP175-4F01 175W 249 183 13.5 3.0A 3.5A +12V 4.0A 4.0A +24V 6.0A +5VSB 2.5A +5VSB 4.0A +24V +5.2VSB +5VSB 0.05A
4.0A
1.5A
9.0A
+5VSB 2.5A +5V 3A
1.0A
+12V +24V FSP361-3F01(361W) FSP361-3F01 361W 240 155 30 3.0A 13.0A +24V +24V FSP368-4F02(368W)
ER-0898/1999
+5VSB 1A
FSP368-4F02
35
12A
2.5A
reference photo
INPUT SPECIFICATION Input Voltage Input Frequency Input Current Inrush Current Earth leakage current Efficiency PFC Power Saving
100V~240V 47~63 Hz Max 1.7A @ 90Vac Max. Load Max 0.7A @ 264Vac Max. Load Max. 100A @ 100Vin Max. load and 25ambient cold start Max. 150A @ 240Vin Max. load and 25ambient cold start Max. 0.25mA @ 264Vac/60Hz Average Efficiency 84% @ 120Vac Max. Load 0.95, DC output with Max. load at 100Vac 1W, It must be measured in PWR_ON signal is low & 264Vac with +5Vs/0.05A
OUTPUT SPECIFICATION Output Voltage/ Current See Product Series List Ripple and noise 120mV p-p @ +12V output / 240mV p-p @ +24V output 100mV p-p @ 5Vsb output Over Voltage Protection Shut down and no damage. +5Vsb: Max.10A / +12V: Max.6.7A / +24V: Max.2.4A Over Current Protection +5Vsb: Max.8V / +12V: Max.16V / +24V: Max.30V Short Circuit Protection Hold up Time ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Storage Humidity EMC Emission ESD EFT SURGE Harmonics Hi-Pot Shut down and no damage. Min. 10mS, applied the AC input voltage is 100Vac/240V
FCC, CLASS B Conducted / Class B Radiated CISPR 22 CLASS B IEC61000-4-2, Contact 8KV and Air 6 KV (Note:conbine with customer's system) IEC61000-4-4, 2KV applied to AC line, pluse the duration 50nS period 5 min IEC61000-4-5, 3KV applied differential mode, 3KV applied common mode 10mA
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
Output Current Output 1 V +12V I(Max) 2.7A Output 2 V +24V Output 3 Output 4 V I(Max) Dimension (mm) L 232 W 113.5 H 25 I(Max) V I(Max) 2.5A +5VSB 4A
112W
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
reference photo
INPUT SPECIFICATION Input Voltage Input Frequency Input Current Inrush Current Earth leakage current Efficiency PFC Power Saving
Max. 0.5mA @ 264Vac/60Hz Average Efficiency 87% @ 240Vac Max. Load Build In 0.5W, It must be measured in PWR_ON signal is low & +5Vs no load at 240Vac/50Hz
OUTPUT SPECIFICATION Output Voltage/ Current See Product Series List Ripple and noise 150mV p-p @ +12V output / 250mV p-p @ +24V output 100mV p-p @ 5Vsb output Over Voltage Protection Shut down and no damage. Over Current Protection Short Circuit Protection Hold up Time ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Storage Humidity EMC Emission ESD EFT SURGE Harmonics Hi-Pot Shut down and no damage. Shut down and no damage. Min. 5mS, applied the AC input voltage is 240Vac
FCC CLASS B CISPR 22 CLASS B IEC 61000-4-2, Air Discharge: 8KV, Contact Discharge: 6KV IEC 61000-4-4, 1KV applied to AC line, pluse the duration 50nS period 5 min IEC 61000-4-5, 2KV applied between L, N, pluse rise time 1.2us and duty time 50uS IEC 61000-3-2, 230Vac/50Hz (Note: Coimbine with customber's system)
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
Output Current Output 1 V +12V I(Max) 2.5A Output 2 V +24V Output 3 Output 4 V I(Max) Dimension (mm) L 180 W 130 H 23 I(Max) V I(Max) 3A +5VSB 2.5A
115W
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
reference photo
INPUT SPECIFICATION Input Voltage Input Frequency Input Current Inrush Current Earth leakage current Efficiency PFC Power Saving
220Vac / 240Vac 47~63 Hz Max 0.7A@240Vac Typicla Load Max.70A @ 220Vac Cold start Max. 0.35mA @ 240Vac/60Hz Average Efficiency 87% @ 240Vac Max. Load Active 0.3W, It must be measured in PWR_ON signal is low & +5Vs no load at 240Vac/50Hz
OUTPUT SPECIFICATION Output Voltage/ Current See Product Series List Ripple and noise 150mV p-p @ +12V output / 250mV p-p @ +24V output 100mV p-p @ 5Vsb output Over Voltage Protection Shut down and no damage. Over Current Protection Short Circuit Protection Hold up Time ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Storage Humidity EMC Emission ESD EFT SURGE Harmonics Hi-Pot Shut down and no damage. Shut down and no damage. Comibne with system
FCC CLASS B CISPR 22 CLASS B IEC 61000-4-2, Air Discharge: 15KV, Contact Discharge: 8KV IEC 61000-4-4, 1KV applied to AC line, pluse the duration 50nS period 5 min IEC 61000-4-5, 1KV applied differential mode, 2KV applied common mode IEC 61000-3-2, 230Vac/50Hz (Note: Coimbine with customber's system)
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
Output Current Output 1 V +12V I(Max) 4.3A Output 2 V +24V Output 3 Output 4 V I(Max) Dimension (mm) L 180 W 130 H 25 I(Max) V I(Max) 2.8A +5VSB 2.5A
132W
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
INPUT SPECIFICATION Input Voltage Input Frequency Input Current Inrush Current Earth leakage current Efficiency PFC Power Saving
140Vac/ 264Vac 47~63 Hz Max. 0.75A@240Vac Full load Max.70A @ 220Vac Cold start Max. 0.5mA @ 240Vac/60Hz Average Efficiency 87% @ 240Vac Max. Load Acitve 0.3W, It must be measured in PWR_ON signal is low & +5Vs no load at 240Vac/50Hz
OUTPUT SPECIFICATION Output Voltage/ Current See Product Series List Ripple and noise 150mV p-p @ +12V output / 250mV p-p @ +24V output 100mV p-p @ 5Vsb output Over Voltage Protection Shut down and no damage. Over Current Protection Short Circuit Protection Hold up Time ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Storage Humidity EMC Emission ESD EFT SURGE Harmonics Hi-Pot Shut down and no damage. Shut down and no damage. Min. 5mS applied the AC input voltage is 240Vac and Full load
FCC CLASS B CISPR 22 CLASS B IEC 61000-4-2, Air Discharge: 8KV, Contact Discharge: 6KV IEC 61000-4-4, 1KV applied to AC line, pluse the duration 50nS period 5 min IEC 61000-4-5, 2KV applied between L, N, pulse rise time 1.2us and duty time 50us IEC 61000-3-2, 230Vac/50Hz (Note: Coimbine with customber's system)
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
Output Current Output 1 V +12V I(Max) 1.5A Output 2 V +24V Output 3 Output 4 V I(Max) Dimension (mm) L 180 W 130 H 25 I(Max) V I(Max) 4.5A +5VSB 2.5A
139W
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
reference photo
INPUT SPECIFICATION Input Voltage Input Frequency Input Current Inrush Current Earth leakage current Efficiency PFC Power Saving
Max. 0.5mA @ 240Vac/60Hz Average Efficiency 85% @ 240Vac Max. Load Active 0.35W, It must be measured in ON/OFF signal is L& 230Vac/50Hz, 5Vs@30mA
OUTPUT SPECIFICATION Output Voltage/ Current See Product Series List Ripple and noise +5V, +12V and +5Vsb output: 100mV p-p +24V output: 250mV p-p Over Voltage Protection Shut down and no damage. Over Current Protection Short Circuit Protection Hold up Time ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Storage Humidity EMC Emission ESD EFT SURGE Harmonics Hi-Pot Shut down and no damage. Shut down and no damage. Min. 20mS applied the AC input voltage is 240Vac and Full load
FCC CLASS B CISPR 22 CLASS B IEC 61000-4-2, Air Discharge: 15KV, Contact Discharge: 8KV IEC 61000-4-4, 4KV between L,N,PE, Pulse duration 15ms, Pluse period 300ms IEC 61000-4-5, 3KV applied between L, N, pulse rise time 1.2us and duty time 50us IEC 61000-3-2, 230Vac/50Hz (Note: Coimbine with customber's system)
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
Output Current Output 1 V +12V I(Max) 2.5A Output 2 V +24V I(Max) 5.0A Output 3 V +5V Output 4 Dimension (mm) L 291 W 213 H 15 I(Max) V I(Max) 3.0A +5VSB 0.05A
145W
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
INPUT SPECIFICATION Input Voltage Input Frequency Input Current Inrush Current Earth leakage current Efficiency PFC Power Saving
220Vac / 240Vac 47~63 Hz Max. 2A@ 198Vac Full load Max.1.2A @ 264Vac Full load Max. 150A @ 240Vac input Max. load and 25ambient cold start Max. 0.5mA @ 240Vac/60Hz Average Efficiency 80% @ 240Vac Max. Load 0.9, DC output with full loading at 240Vac 1W, Power down pin is low and the loading of+5Vsb is 80mA at 264Vac
OUTPUT SPECIFICATION Output Voltage/ Current See Product Series List Ripple and noise +5.1Vsb output: 100mV p-p / +12V output: 120mV p-p +24V output: 240mV p-p Over Voltage Protection +5.1Vsb: Max. 8V / +12V: Max. 16V / +24V: Max. 30V Over Current Protection Short Circuit Protection Hold up Time ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Storage Humidity EMC Emission ESD EFT SURGE Harmonics Hi-Pot +5.1Vsb: 6.0A ~ 8.5A, +12V: 6.5A~9A, +24V: 6.0A ~ 8.0A Shut down and no damage. Min. 10mS at 220Vac/50Hz with full loading
FCC: Part15J CLASS B CISPR 22 CLASS B IEC 61000-4-2, Air Discharge: 15KV, Contact Discharge: 8KV IEC 61000-4-4, 1KV applied to AC line, pulse Duration 200uS period 1 min. IEC 61000-4-5, 4KV applied diffentical mode, 5KV common mode 10mA(Lab test), 5mA(Product line)
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
Output Current Output 1 V +12V I(Max) 3.5A Output 2 V +24V Output 3 Output 4 V I(Max) Dimension (mm) L 260 W 225 H 15 I(Max) V I(Max) 3.5A +5.1VSB 4.0A
146W
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
INPUT SPECIFICATION Input Voltage Input Frequency Input Current Inrush Current Earth leakage current Efficiency PFC Power Saving
Max. 0.5mA Average Efficiency 85% @ 230Vac/50Hz Typical Load Active 0.35W, It must be measured in ON/OFF signal is L& 230Vac/50Hz, 5Vs@30mA
OUTPUT SPECIFICATION Output Voltage/ Current See Product Series List Ripple and noise +5V, +5Vsb, + 12V output: 100mV p-p +24V output: 250mV p-p Over Voltage Protection Shut down and no damage. Over Current Protection Short Circuit Protection Hold up Time ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Storage Humidity EMC Emission ESD EFT SURGE Harmonics Hi-Pot Shut down and no damage. Shut down and no damage. Min. 20mS, applied the AC input voltage is 240Vac TYP load
FCC CLASS B CISPR 22 CLASS B IEC 61000-4-2, Air Discharge: 15KV, Contact Discharge: 8KV IEC 61000-4-4, 4KV applied Between L,N,PE, Pluse duration 15ms period 300ms IEC 61000-4-5, 3KV applied between L,N, pluse rise time 1.2us and duty time 50uS IEC 61000-3-2, 230Vac / 50Hz
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
Output Current Output 1 V +5V I(Max) 3.0A Output 2 V +12V I(Max) 4.0A Output 3 V
+24V
Output 4
175W
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
INPUT SPECIFICATION Input Voltage Input Frequency Input Current Inrush Current Earth leakage current Efficiency PFC Power Saving
Max. 0.5mA @ 240Vac/50Hz & 100Vac/60Hz Average Efficiency 85% @ 230Vac Full load Active 1W, It must be measured in PSON signal is low condition at input 240Vac and no load.
OUTPUT SPECIFICATION Output Voltage/ Current See Product Series List Ripple and noise +5Vsb output: 100mV p-p / +12V output: 200mV p-p +24V output: 400mV Over Voltage Protection Shut down and no damage. Over Current Protection Short Circuit Protection Hold up Time ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Storage Humidity EMC Emission ESD EFT SURGE Harmonics Hi-Pot Shut down and no damage. Min. 5mS, applied the AC input voltage is 100Vac/240Vac
FCC CLASS B CISPR 22 CLASS B IEC 61000-4-2, Air Discharge: 8KV, Contact Discharge: 6KV IEC 61000-4-4, 1KV applied to AC line, pulse Duration 200uS period 1 min. IEC 61000-4-5, 1KV applied diffentical mode, 2KV common mode IEC 61000-3-2
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
Output Current Output 1 V +12V I(Max) 4.7A Output 2 V +24V Output 3 Output 4 V I(Max) Dimension (mm) L 240 W 135 H 27 I(Max) V I(Max) 5.5A +5VSB 2.5A
201W
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
reference photo
INPUT SPECIFICATION Input Voltage Input Frequency Input Current Inrush Current Earth leakage current Efficiency PFC Power Saving
Max. 0.5mA @ 240Vac/ 50Hz and 100Vac/60Hz Average Efficiency 86% @ 240Vac Full load Active 1W, It must be measured in PSON signal is low condition.
OUTPUT SPECIFICATION Output Voltage/ Current See Product Series List Ripple and noise +5Vsb output: 50mV p-p / +12V output: 80mV p-p +24V output: 350mV p-p Over Voltage Protection +5Vsb : 6.0V~9.0V / +12V : 13.0V~ 17.0V / +24V : 26.0V~31.0V Over Current Protection Short Circuit Protection Hold up Time ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Storage Humidity EMC Emission ESD EFT SURGE Harmonics Hi-Pot +5Vsb : 4.5A~7.0A / +12V : 4.5A~10.0A / +24V : 6.5A~11.0A Shut down and no damage. Min. 5mS, applied the AC input voltage is 100Vac or 240Vac and full load
FCC CLASS B CISPR 22 CLASS B IEC 61000-4-2, Air Discharge: 8KV, Contact Discharge: 6KV IEC 61000-4-4, 1KV applied to AC line, pulse Duration 50uS period 1 min. IEC 61000-4-5, 2KV applied between L, N, PE, pulse rise time 1.2us and duty time 50us IEC 61000-3-2
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
Output Current Output 1 V +12V I(Max) 4.0A Output 2 V +24V Output 3 Output 4 V I(Max) Dimension (mm) L 200 W 130 H 32 I(Max) V I(Max) 6.0A +5VSB 4.0A
212W
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
INPUT SPECIFICATION Input Voltage Input Frequency Input Current Inrush Current Earth leakage current Efficiency PFC Power Saving
100V ~ 240V 47~63 Hz Max. 4.2A @ 100Vac/ Max. load Max. 50A @ 100Vac/ 240Vac, Max. load and 25C Max. 0.7mA @ 240Vac/50Hz Average Efficiency 85% @ 240Vac Full load Active 1W, Input AC at 230V & output is less than 0.4W, when ON/OFF is low or open.
OUTPUT SPECIFICATION Output Voltage/ Current See Product Series List Ripple and noise +5.2V, +5.2Vsb: 100mV p-p +24V: 250mV p-p Over Voltage Protection No broken, no somke Over Current Protection Short Circuit Protection Hold up Time ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Storage Humidity EMC Emission ESD EFT SURGE Harmonics Hi-Pot Auto-recobery or latch off
FCC CLASS B CISPR 22 CLASS B IEC 61000-4-2, Air Discharge: 8KV, Contact Discharge: 6KV IEC 61000-4-4, 1KV applied to AC line, pulse Duration 50uS period 1 min. IEC 61000-4-5, 2KV applied between L, N, PE, pulse rise time 1.2us and duty time 50us IEC 61000-3-2 / GB17625.1 D
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
Output Current Output 1 V I(Max) +5.2V 4.0A Output 2 V +24V I(Max) 1.5A Output 3 V
+24V
Output 4
264W
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
reference photo
INPUT SPECIFICATION Input Voltage Input Frequency Input Current Inrush Current Earth leakage current Efficiency PFC Power Saving
Max. 0.5mA @ 240Vac/50Hz Average Efficiency 85% @ 230Vac Full load Active 0.5W, measured in PWR_ON signal is low condition at rated AC input
OUTPUT SPECIFICATION Output Voltage/ Current See Product Series List Ripple and noise +5V, +5Vsb output: 120mV p-p +24V, +24VA output: 400mV p-p Over Voltage Protection Shoutdown and no damage Over Current Protection Short Circuit Protection Hold up Time ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Storage Humidity EMC Emission ESD EFT SURGE Harmonics Hi-Pot Shoutdown and no damage Shoutdown and no damage Min. 5mS, applied the AC input voltage is 240Vac and output load is Full load.
FCC, Class B Conducted / Class B Radiated IEC61000-4-2, Contact 8KV and Air 6 KV (Note:conbine with customer's system) IEC61000-4-4, 1KV applied to AC line, pulse duration 50nS period 5 min IEC61000-4-5, 2KV applied between L, N, pulse rise time 1.2us and duty time 50us IEC61000-3-2, 230Vac/ 50Hz
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
Output Current Output 1 V +12V I(Max) 3.0A Output 2 V +24V Output 3 Output 4 V I(Max) Dimension (mm) L 240 W 155 H 30 I(Max) V I(Max) 13.0A +5VSB 2.5A
361W
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
reference photo
INPUT SPECIFICATION Input Voltage Input Frequency Input Current Inrush Current Earth leakage current Efficiency PFC Power Saving
Max. 0.7mA @ 264Vac/50Hz Average Efficiency 86% @ 230Vac Full load Active 1W, measured in PWR_ON signal is low condition at rated AC input
OUTPUT SPECIFICATION Output Voltage/ Current See Product Series List Ripple and noise +5V, +5Vsb output: 120mV p-p +24V, +24VA output: 400mV p-p Over Voltage Protection Shoutdown and no damage Over Current Protection Short Circuit Protection Hold up Time ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Storage Humidity EMC Emission ESD EFT SURGE Harmonics Hi-Pot Shoutdown and no damage Shoutdown and no damage Min. 10mS @ 100Vac Full load
FCC, Class B Conducted / Class B Radiated IEC61000-4-2, Contact 8KV and Air 6 KV (Note:conbine with customer's system) IEC61000-4-4, 1KV applied to AC line IEC61000-4-5, 1KV applied between L, N and PE IEC61000-3-2, 230Vac/ 50Hz
This content is subject to change, please refer to Specification for more detail. FSP reserve the right to change the content without prior noitce.
Output Current Output 1 V +24V I(Max) 12A Output 2 V +24V I(Max) 2.5A Output 3 V +5V Output 4 Dimension (mm) L 300 W 180 H 35 I(Max) V I(Max) 3A +5VSB 1A
368W