Professional Documents
Culture Documents
TOFD
UT
Phased
Array
Ultracloud
Ultracloud refers to the core technology of SIUI, the innovation derived from the interdisciplinary efforts of modern physics, biology, acoustics,
electronics, computer technology and network technology.
It breaks the limitation of traditional technology platform, achieves unlimited expansion of technical processing resources, improves processing
speed of the system and optimizes resources allocation, so as to enhance the ability to adapt to future needs. It enables customers to obtain needed
service with SIUI products anytime and anywhere.
Phased Array
Multi-Group Scanning
For one phased array probe, multi groups of element and multi angles can be applied for scanning at the same time,
fully covering the welding area and enhancing the inspection efficiency.
2 Groups of PA Scanning
Weld Simulation
Weld Simulation is to simulate how phased array ultrasound propagates
in type V, Y or X flat panel butt weld, so as to help users know the beam coverage status and finish
test process setup.
TOFD
1-4 channels of TOFD function for selection
Negative square wave transmit pulse, adjustable transmit voltage and pulse width
Data Analysis: Lateral Wave / Bottom Wave Straightening, Lateral Wave/ Bottom Wave Filtering, Constrast
Correction, Gain Correction, Flaw Height and Length Measurement
2-channel TOFD
SyncScan Specifications
General Technical Specification
General Technical Specification
Input/Output
Display Screen
USB Connector
2 pcs
Dimension (WHD)
Ethernet Connector
1 pc
Weight
Video Output
VGA port
Language
English/ Russian
Encoder Connector
1 pc (14-core)
Unit
mm/inch
WIFI
Build-in
Battery
Battery Capacity
AC 100240V 50Hz/60Hz
Adaptor
Adaptor Output
15V DC
Power
30VA
Data Storage
IP Code
IP65
Environment Tests
Operation Temperature
040
Storage Temperature
-2060
TOFD
System
No. of Channel
Probe Connector
LEMO 00
No. of Probe
Connector
Max. Supporting
Elements
2 pcs
Scan
Scan Type
A/TOFD
Trigger Mode
Encoder
Scan Length
Line Average
4 levels, 1/2/4/8
Calibration
2
Pulser
Range
Material Velocity
Display Delay
Probe Delay
Pulser
Negative square
PRF
Pulse Voltage
Probe Zero
Pulse Width
501000ns, step:10ns
Probe Flank
Damping
50/100/250/500,4 levels
Wizard
TOFD wizard
Measurement
Receiver
Data Analysis
Gain
Bandwidth
0.525MHz-3dB
170MHz
Rectification
RF
Filter
6 levels, 0.55/0.510/3.510/0.5
15/5.015/0.520MHz
Optional Software
SyncScan Specifications
Technical Specification for 16:64 PAUT with optional 1-ch TOFD
to achieve simultaneous inspection of PA & TOFD
SyncScan Specifications
SyncScan Specifications
SyncScan Specifications