RDQJ-2 Suction Hydrocarbon Gas Detecting System
User Manual
Document No.: 2550-200
PC:
200135
TEL:
0086-21-68532791
FAX:
0086-21-58212204
E-mail:
sale@rongded.com
Website
http://www.rongded.com
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
Content
1.
1. Brief introduction
1-1
2.
2-1
2.1
2-1
2.2
2-5
3.
3-1
3. 1
3.1 System
3-1
3. 2
3-1
3. 3
3-1
4.
4. Installation
4-1
4.1
4-1
4.2
4-1
4.3
4-1
4.4
4-1
4.5
4-1
4.6
4.6 Cable
4-1
5.
5-1
5.1
5.1 Start up
5-1
5.2
5-2
5.3
5-6
5.4
5.4 Setting
5-8
5.5
5-17
6.
6-1
6.1
6-1
6.2
6-1
6.3
6-1
6.4
6-1
6.5
6-1
7.
7. Troubleshooting
7-1
Appendix 1
8-1
RDQJ-2
Revision: 2.01
Plan History-Content
0- 1
8-2
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
1.
1. Brief introduction
1.1
1.1 Purpose
RDQJ-2
,
,
1.2
IACS UR F43
(2002 6 2 )
RDQJ-2
Version: 2.01
1. General description
units
1-1
for
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
2.
2.
2.1
RDQJ-2
1
()
(
)
RONGDE
RUN
DIMMER
Ackn
Test
1 RDQJ-2
Fig.1
RDQJ-2
RDQJ-2
Version: 2.02
2-1
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
20
2.1.1
The Sample Pump is used to deliver the sample air to the gas
detector one by one in the sequence, When the gas
concentration of one sample point reaches or exceeds the alarm
value, the system will trigger an audible and visual alarm.
Among those the gas detector for cabinet itself is used to detect
the flammable gas inside this cabinet.
2.1
RDQJ-2
Version: 2.02
2-2
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
PC3025J
24V DC
PC3025J
24V DC
2.1
Fig.2.1 A picture of inner structure for detection cabinet
2.1.2
2.2
All adjustment, setting, control and display are carried out by the
Touch Screen on the front panel, The buzzer, warning lamps,
pushbuttons for silencing, de-flashing and lamp test are also
arranged on the front panel. The layout of the front panel of alarm
and control panel is shown in Fig. 2.2.
RDQJ-2
Version: 2.02
2-3
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
Display panel
System
Buzzer failure
2.2
Fig. 2.2 Front panel layout of alarm and control panel
2.1.3
2.1.4
RDQJ-2
Version: 2.02
2-4
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
2.2
Detecting Alarm
and Control Panel
11
12
13
14
15
16
17
18
19
20
Test Gas
Ball valve
Flame arresters
BG1
Gas detector
Y11A
Y12A
Y14A
Y13A
A
Y15A
Y16A
Y17A
Y18A
Y19A
Y20A
Y03
A
P
Y11B
Y12B
Y14B
Y15B
Y13B
Y16B
Y18B
Y17B
Y2B
Y3B
Y4B
Y5B
Y7B
Y6B
Y8B
Y9B
Y20B
Y1A
Y2A
Y3A
Y4A
Y5A
Y6A
Y7A
Y8A
Y9A
P PS3
P PS4
Y10A
Predrainage
Pressure switch
P PS1
Sample loop
Pressure switch
Pre-draining Pump
M1
PS2
BG2
Flame arresters
()
Cabinet gas
detector
Y01
PS5
Predrainage
Pressure switch
Ball valve
Flow regulator
Sample loop
M17
Pressure switch
Y10B
Sample pump
M2
Y1B
Y02
Y19B
Exhaust
10
Air supply
Shipyard supply
/Exhaust
Pre-pumping gas
2.3
Fig. 2.3 Block Diagram of Gas Detection System
In MANUAL mode, the system will only scan the sample point
which has been selected by manual before starting.
2.3
1 Y1A
Y1A
Y1B
1
RDQJ-2
Version: 2.02
read this section. In AUTOMATIC mode, first of all the sample air
is to be pre-drawn from No.1 sample point by Main Pump (Y1A
sampling solenoid valve opens and main pump runs), sampling
time is based on the maximum length of each sampling line. After
the sampling time is over, Y1A sample solenoid valve closes and
Y1B analysis solenoid valve opens, and then sample pump runs.
The sample air from No.1 sample point will be delivered to the
gas detection transmitter (i.e., Gas Detector for short name) for
detecting by Sample Pump. At same time, Main Pump is turned
2-5
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
Y1A
Y2A
2
15
1 Y1B
RDQJ-2
Version: 2.02
2-6
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
3.1
: 10%30% LEL
20%30% LEL
-30kPa
0.2MPa
15s
3.2
20
3.3
DC24V1226V
1.2W
RDQJ-2
Version:2.01
3-1
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
420mA
Detecting accuracy: 5
IP54
Protection: IP54
<15S
RDQJ-2
Version:2.01
3-2
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
4.
4. Installation
4.1
800mm
4-14-2 Below Fig.4-1~Fig.4-2 are the mounting size of each cabinet for
reference.
Display panel
System
Buzzer failure
4-1
Fig.4-1 Mounting size of Alarm and Control Panel
RDQJ-2
Version: 2.01
4. Installation
4-1
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
600
4-?14
560
171
145
85
525
469
43
55
55
1225
1275
1325
86
43
188
4-3
Fig.4-3 Layout of Detection Cabinet
4.2
4.3 4.3 Sample gas outlet should be set in the safe area and
discharge the sample gas to the open atmosphere within a safe
location.
4.4 4.4 The bulkhead penetrator (or sample pipe) between safe and
hazardous areas should have the fire integrity same as the
compartment of bulkhead.
Every relevant of the sample gas line on the bulkhead of the safe
side should be installed with a hand-operation isolating valve.
4.3 Fig.4.3 is the installation sketch map of sampling pipe lines for
reference purpose.
RDQJ-2
Version: 2.01
4. Installation
4-2
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
Note:
The installation of sampling pipe lines should be carried out
according to the drawings provided with the equipment.
Clamping of the piping shall be performed according to
good practice and prevailing rules. Piping fittings or flanges
of good quality shall be used, and materials in the
fittings/flanges shall be selected to fit the material in the
piping. All piping shall be flushed prior and the pipe ends are
kept sealed at all times before connection.
Note:
All cables must be connected according to drawings
provided with the equipment. Connection and clamping shall
be also performed according to good practice and prevailing
rules.
4.3
Fig.4.3 Sampling pipe lines installation sketch map
RDQJ-2
Version: 2.01
4. Installation
4-3
RONGDE
5.
The system has two operation modes: Auto detection and Manual
operation.
5.1
5.1 Start-up
,
STANDBY
5.1
30s
0.15MPa
30s
5.1
Fig.5.1 System startup interface
(2) The system automatically switches to MAIN MENU interface
5.2 after finished with the preparation phase, as shown on fig.5.2.
AUTO Interface displays three options: AUTO, MANUAL and SET
MANUAL SET
RDQJ-2
Version: 2.01
5-1
RONGDE
5.2
Fig.5.2 MAIN MENU interface
20s (3) After 20s, if user has no any acting, then the system enters
AUTO AUTO SEQUENCE CONTROL operation mode automatically.
SEQUENCE CONTROL( Refer to the interface as shown in Fig.5.3.
) 5.3
5.2
Channel State
:
White: Normal
:
Yellow: Override
:
White: Normal
:
Green: is being
pre-drained
:
White: Normal
:
Green: is being
detected
5.3
Fig.5.3 Auto detecting interface
RDQJ-2
Version: 2.01
:
GreyUnavailable
Channel
5-2
RONGDE
l Override Point (
)
l Pre-drainage Point (
: )
l Sample Point (:
)
l Alarm Point
l Gas Detector
0.0%LEL:
ALM: l
it
is
being
AUTO:
MANU
PURGE
SAMP
SET
Remarks:
20
Override( ) Pre-drainage
Point ()Sample Point
()
Override,
For the Override, the color of the circle graph is white when the
detection point is normal or is being detected. The color will
become yellow if this detection point is overridden by manual or
auto operation. The detection channel is unavailable if the color is
RDQJ-2
Version: 2.01
5-3
RONGDE
grey.
Pre-drainage Point, For Pre-draining Point, the color of the circle graph is white during
this detection point is normal and not detected in the state. If the
green color, it shows that this point now is being detected.
Sample Point
Pre-drainage Point
5.4 ,
HC Gas 0.0 (%LEL)
( ) Cabinet
Gas 0.0 (%LEL) (
)
RDQJ-2
Version: 2.01
means this point is normal and not detected, while green means
this point is being detected.
5-4
RONGDE
5.4
Fig.5.4 Gas concentration display interface
5.5
Fig.5.5 Each flammable gas concentration interface
ALARM
RECORD
5.6
RDQJ-2
Version: 2.01
5-5
RONGDE
100
100
ALARM RECORD
5.6 WB3 Gas high
NAME 2
(5) If want to stop running automatic mode, touch EXIT key in the
AUTO SEQUENCE CONTROL AUTO SEQUENCE CONTROL interface, the system will stop
() 5.3 running automatic mode and return to MAIN MENU interface.
EXIT
5.6
Fig.5.6 Alarm Record Interface
5.3
MAIN MENU() (1) Push MANUAL button on MAIN MENU interface, screen
MANUAL switches to MANUAL CONTROL window, its interface is shown
in Fig.5.7
5.7
RDQJ-2
Version: 2.01
5-6
RONGDE
5.7
Fig.5.7 MANUAL CONTROL interface
3
3
AUTO SEQUENCE CONTROL
()
5.2 5.4
5.23
MAIN MENU
MAIN MENU
20 AUTO
MANUAL CONTROL (5) Push Back key on MANUAL CONTROL window, the
Back interface will return to MAIN MENU interface.
MAIN MENU ()
RDQJ-2
Version: 2.01
5-7
RONGDE
5.4
MAIN MENU() (1) Push SET button on MAIN MENU interface to enter system
SET setting procedure. Firstly the password window comes on screen,
as shown in Fig.5.8.
5.8
5.8
Fig.5.8 Code input interface before enter setting
(2) Touch the code input window, and then pop-up soft keypad
5.9
(Fig.5.9).
5.9
Fig.5.9 Code input interface
RDQJ-2
Version: 2.01
5-8
RONGDE
3 1234 ENT
ENTER
OPERATION MENU()
5.10
ALARM SET -
OVERRIDE -
5.4.1
GAS DETECTOR ZERO (1) Push GAS DETECTOR ZERO CALIBRATION button, enter
CALIBRATION the detector zero setting interface (shown in Fig.5.11-1). At that
time, the cleaning air solenoid valve opens to purge the gas
5.11-1
detector for cleaning the detector inside.
RDQJ-2
Version: 2.01
5-9
RONGDE
5.11-1
Fig.5.11-1 Detector zero setting interface
START
MONITOR
VALUE SET
5.11-2
5.11-2
Fig.5.11-2 Detector zero set interface
0 Calibration
0 AD
AD 0
Calibrate AD
PLC
RDQJ-2
Version: 2.01
5-10
RONGDE
START MONITOR set interface (OPERATION MENU). Zero set (or calibration) is
Back now finished.
5.4.2
5.12
Fig.5.12 Detector range calibration interface
GAS DETECTOR (1) Push GAS DETECTOR CALIBRATION button, enter the
CALIBRATIOM interface for detector arrange calibration (shown in Fig.5.12).
5.12
5.13
Fig.5.13 Detector range calibration input interface
RDQJ-2
Version: 2.01
5-11
RONGDE
30LEL (2) Connect the standard test gas (e.g. 30%LEL propane) to the
range calibration joint inside of detection cabinet, open the pipe
calibration valve inside the cabinet, the detection pump is running
30LEL
(3) The interface will display the electric current value of 30%LEL
standard test gas, for a sample, CURRENT VALUE 11.0.
30 LEL
5.13
11.0 ENT
Back
(4) Push 30% LEL, switch to range calibration input interface (as
shown in Fig.5.13), input 11.0 by keyboard and push ENT key to
confirm. After that the setting for detector range calibration is
finished, then push Back key to return to system setting interface
(OPERATION MENU). Now the detector range calibration is
finished.
10 LEL 50 LEL (5) The detector range calibration for 10 LEL and 50 LEL
5.4.3
ALARM SET
5.14
(1) Push ALM SET button, enter the gas alarm setting interface
(GAS DETECTOR ALARM SET), as shown in Fig.5.14).
5.14
Fig.5.14 Detector gas alarm setting interface
RDQJ-2
Version: 2.01
5-12
RONGDE
GAS DETECTOR
ALARM.SET
10
ENT
5.15
5.15
Fig.5.15 Detector gas alarm setting interface
Back
(OPERATION MENU)
(3) Touch Back key, the screen returns to the system set
interface (OPERATION MENU).
5.4.4
RDQJ-2
Version: 2.01
5-13
RONGDE
5.16
Fig.5.16 Manual override setting interface for sample points
1 OPERATION MENU( 1Push OVERRIDE key on OPERATION MENU interface, the
) OVERRIDE interface will switch to OVER RIDE CONTROL interface. Fig.5.16
shows this interface.
OVER RIDE CONTROL
5.16
OVER RIDE
CONTROL
( 1820)
ON OFF
OFF
ON
Touch this No. button (for example, 18~20), the letter ON at the
right frame will become OFF. It indicates that this point of gas
sample is overridden. Touch this button again, the letter OFF will
become ON again if it is required to list this gas sample into the
gas detection.
5.2
AUTO SEQUENCE CONTROL
5.16
OFF.
OFF ON
Remarks:
During system running process, if one fault monitor point is failure
(e.g. sample pressure is low). It thereby affects the normal
sample detection function, this channel will be overridden and
trigger an alarm automatically. By this time, the overridden point
will be became yellow color in the interface of AUTO SEQUENCE
CONTROL (Fig.5.2). At the same time, OFF comes at the right
block of this channel No. Touch this button with two times the
OFF changes into ON after the fault removed. Meantime this
channel is at detected status now.
RDQJ-2
Version: 2.01
5-14
RONGDE
5.4.5
20
5.17-1
Fig.5.17-1 Setting the sample channel number
(2) + -
( 17) USE
,
5.17-2
RDQJ-2
Version: 2.01
5-15
RONGDE
5.17-2
Fig.5.17-2 Setting the sample channel number
AUTO SEQUENCE
CONTROL GAS CONTENT
13~20
1720
5.17-3 5.17-4.
At the same time, channels of 17~20 are changes into grey color
and those channels now becomes unavailable in the interfaces of
AUTO SEQUENCE CONTROL and GAS CONTENT 13~20, as
shown in Fig.5.17-3 and Fig.5.17-4
5.17-3 1720
Fig.5.17-3 Channels of 17~20 are inhibited and unavailable
RDQJ-2
Version: 2.01
5-16
RONGDE
5.17-4 1720
Fig.5.17-4 Channels of 17~20 are inhibited and unavailable
3 Back
(OPERATION MENU)
5.5
5.5.1
5.5.1 When the gas detector is failure, the system will stop to
detect sample gas automatically and trigger a failure alarm. At the
same time, item GAS DETECTOR shows FAIL in yellow color in
the interface of Fig.5.3.
5.5.2 5.5.2 When the hydrocarbon gas density inside the sample
30LEL cabinet is more than 30%LEL, the system will automatically stop
sampling.
Meantime:
SYSTEM l
FAIL
ALARM l
RECORD
5.3 l
5.4
CANINET GAS
RDQJ-2
Version: 2.01
5-17
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
6.
6.1
Gas alarm
(Power failure
)
System
failure
Override
System
Buzzer failure
6.1
Fig. 6.1 The indicators and operation buttons on alrm and control panel
6.2
,
Gas alarm
RDQJ-2
Version: 2.01
6-1
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
Ackn(), ,
,.
.
(2) Push Ackn pushbutton, the alarm indicator stops flash and
keeps steady lighting until the alarm signal disappears. The alarm
lamp goes out automatically after the fault removed.
6.3 6.3 When the any pre-draining pump alarm (vacuum pressure is
System alarm( abnormal) is caused, the System alarm indicator flashes. Then
) check according to following two ways to remove the failure:
6.4 6.4 When any line of sample pressure comes alarm (sample
System alarm( pressure is abnormal), the System alarm indicator flashes. Then
) check according to following two ways to remove the failure:
6.5 Test 6.5 The indicators and buzzer can be tested by pushing Test
button.
6.6 1
2
RDQJ-2
Version: 2.01
6-2
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
7.0
7.0 Troubleshooting
(1)
Cause:
a,
a, Wrong wiring
b,
b, PCB failure
c,
c, Power failure
Actions
a,
b,
c,
(2)
Cause:
a,
a, Zero excursion
b,
b, Sensor fault
Actions:
a,
b,
(3)
Cause:
a,
b,
b, Sensor failure
c,
c, PCB fault
d,
d, Electro disturbance
Actions:
a,
b,
c,
d,
RDQJ-2
Version: 2.01
7.0 Troubleshooting
7-1
RONGDE
RDQJ-2
Document No.: 2550-200-0-05
User Manual for RDQJ-2 Suction Type Gas Detecting System
(4)
Cause;
a,
b,
b, Sensor failure
c,
c, PCB failure
Actions:
a,
b,
c,
Order Notice
a.
a, Detected points
b.
c.
RDQJ-2
Version: 2.01
7.0 Troubleshooting
7-2
RONGDE
RDQJ-2
User Manual for RDQJ-2 Suction Type Gas Detecting System
Appendix 1
Gas name
Chemical formula
--%
Explosive limit in air (volume fraction) / %
Upper limit
Lower limit
CO
12.5
74
CS2
1.0
60
Ethane
C2H6
3.0
15.5
Ethanol
C2H5OH
3.4
19
Ethene
C2H4
2.8
32
Acetylene
C2H2
1.5
100
Aether
C2H5OC2H5
1.7
36
Methane
CH4
5.0
15
Methanol
CH3OH
5.5
44
Toluol
C6H5CH3
1.2
Propane
C3H8
2.2
9.5
Propylene
C3H6
2.4
10.3
C3H7Cl
2.6
11.1
Ammonia
NH3
15
30.2
Benzene
C6H8
1.2
HCHO
7.0
73
0.7
4.0
75
Carbon monoxide
Carbon bisulfide
Chloropropane
Formaldegyde
Kerosene
Hydrogen
H2
Turpentine
0.8
Light oil
0.9
RDQJ-2
Version: 2.01
8.0 Appendix
8-1
RONGDE
RDQJ-2
User Manual for RDQJ-2 Suction Type Gas Detecting System
// ()
Appendix 2
English
Chinese
1#
1#
1#
1#
1#
1#
2#
2#
2#
2#
2#
2#
3#
3#
3#
3#
3#
3#
4#
4#
4#
4#
4#
4#
5#
RDQJ-2
Version: 2.01
8.0 Appendix
8-2
RONGDE
RDQJ-2
User Manual for RDQJ-2 Suction Type Gas Detecting System
Abbreviation
English
Chinese
5#
5#
5#
5#
5#
6#
6#
6#
6#
6#
6#
Abbreviation
English
Chinese
F.P.T Override
F.P.T Override
1P WBT Override
1P W.B.T Override
1#
1S WBT Override
1S W.B.T Override
1#
2P WBT Override
2P W.B.T Override
2#
2S WBT Override
2S W.B.T Override
2#
3P WBT Override
3P W.B.T Override
3#
3S WBT Override
3S W.B.T Override
3#
4P WBT Override
4P W.B.T Override
4#
4S WBT Override
4S W.B.T Override
4#
5P WBT Override
5P W.B.T Override
5#
5S WBT Override
5S W.B.T Override
5#
6P WBT Override
6P W.B.T Override
6#
RDQJ-2
Version: 2.01
8.0 Appendix
8-3
RONGDE
RDQJ-2
User Manual for RDQJ-2 Suction Type Gas Detecting System
Abbreviation
English
Chinese
6S WBT Override
6S W.B.T Override
6#
WBT Override
W.B.T Override
RDQJ-2
Version: 2.01
8.0 Appendix
8-4