03
PROTECTIVE COATINGS AND LININGS
February 2016
Page 97 of 112
Time / Date
Rel. Humidity (%)
Dewpoint ( C)
Metal Temp. ( C)
SURFACE CONDITION AND DEGREASING (Circle/Highlight as necessary)
Original Status
Metal Condition
Metal Rust Grade ^^
Coating Breakdown ##
Contamination
Degreasing Agent
Coated
Defect-free
A
Ri 0 / 10
Heavy
.
Wrapped
Laminated/Pitted
B
Ri 3 / 6
Light
Swabbed
Bare
Ground
C
Ri 4 / 4
Rejected
D
Ri 5 / 1
Sprayed
Water Tested
Trowel
Other.
Visible Surface Rusting...Yes/No
Overcoating
WFT Range
DFT Range
Period
(um)
(um)
Second Midcoat
Topcoat
FINAL TESTING AND REPAIR (Circle/Highlight as necessary)
Thickness/Appearance
DFT - Accept/Reject
Holiday Detection Test
LV/HV Tester
Coating Adhesion Test
Adhesion Tester
Repaired Areas
% of Total Area..
Test Voltage..
Pull Off Stress
Primary Locations.
Appearance - Accept/Reject
Pass/Fail
Accept/Reject
Rejected Because.
T.P.I. ( If Applicable)
OWNER
GENERAL COMMENTS:
CONTRACTOR
Signature
Name
Position
Date
## CORRESPONDING DEGREES OF COATING RUSTING STANDARDS(ISO 4628-3 / SSPC Vis. 2):
Ri 0/10- No visible rusting of coating; Ri 3/6- Marked localised rusting of 1% of surface area;
Ri 4/4- Widespread localised rusting of 10% surface area (8% for Ri.4); Ri 5/1- Extensive rusting of up to 50% of surface area
^^ Bare Metal Rust Grade standard according to Visual Standard SSPC-Vis 3