Professional Documents
Culture Documents
SD
SD
SCORE: 65%
FAILED
Question 1
Adapters are typically located on the _____.
Your answer (correct): backplane of the circuit packs/modules
Question 2
Bulkhead connectors are typically located on the _____.
Your answer: on the ends of the intra-system fibers jumpers
Correct answer: faceplate of the circuit packs/modules
Question 3
If a fiber connector shows evidence of dirt and requires cleaning, _____.
Your answer: the Cletop cleaning stick should be used to clean the fiber connector
Correct answer: the fiber connector and associated connector it mates with should be cleaned
Question 4
Optical power levels in excess of ______ have the potential to damage fiber connectors by pitting if
mated/demated while the optical signal is present.
Your answer (correct): 16 dBm
Question 5
The fiber and faceplate connections in laser-based telecommunication equipment ______.
Your answer (correct): contain invisible light that is dangerous to view directly with the eye
Question 6
The most dangerous and potentially damaging class of laser ______.
Your answer (correct): is Class 4
Question 7
When cleaning a bulkhead connector or backplane adapter, _____.
Your answer: insert cleaning cartridge straight and firmly into the connector until it clicks. Release and
repeat 5 times. Then remove the cartridge from the connector.
Correct answer: insert cleaning cartridge straight and firmly into the connector until it clicks. Then
remove the cartridge from the connector.
Question 8
When cleaning a fiber connector, _____.
Your answer (correct): a Kimwipe should be used, the Kimwipe should be folded into an 8-ply pad, the
connector face (end) should be cleaned, then the fiber ferrule should be cleaned
Question 9
When cleaning bulkhead connectors or backplane adapters, _____.
Your answer (correct): cleaning cartridges or cleaning sticks are used
Question 10