Post Test

SCORE: 65%
FAILED
Question 1
Adapters are typically located on the _____.
Your answer (correct): backplane of the circuit packs/modules
Question 2
Bulkhead connectors are typically located on the _____.
Your answer: on the ends of the intra-system fibers jumpers
Correct answer: faceplate of the circuit packs/modules
Question 3
If a fiber connector shows evidence of dirt and requires cleaning, _____.
Your answer: the Cletop cleaning stick should be used to clean the fiber connector
Correct answer: the fiber connector and associated connector it mates with should be cleaned
Question 4
Optical power levels in excess of ______ have the potential to damage fiber connectors by pitting if
mated/demated while the optical signal is present.
Your answer (correct): 16 dBm
Question 5
The fiber and faceplate connections in laser-based telecommunication equipment ______.
Your answer (correct): contain invisible light that is dangerous to view directly with the eye
Question 6
The most dangerous and potentially damaging class of laser ______.
Your answer (correct): is Class 4
Question 7
When cleaning a bulkhead connector or backplane adapter, _____.
Your answer: insert cleaning cartridge straight and firmly into the connector until it clicks. Release and
repeat 5 times. Then remove the cartridge from the connector.
Correct answer: insert cleaning cartridge straight and firmly into the connector until it clicks. Then
remove the cartridge from the connector.
Question 8
When cleaning a fiber connector, _____.
Your answer (correct): a Kimwipe should be used, the Kimwipe should be folded into an 8-ply pad, the
connector face (end) should be cleaned, then the fiber ferrule should be cleaned
Question 9
When cleaning bulkhead connectors or backplane adapters, _____.
Your answer (correct): cleaning cartridges or cleaning sticks are used
Question 10

When cleaning fiber connectors, _____.


Your answer: Cletop cleaning sticks are used
Correct answer: Kimwipes or cleaning cartridges are used
Question 11
When cleaning the face (end) of a fiber connector using a Kimwipe, _____.
Your answer: while applying firm pressure to ensure good contact, wipe the connector end only one
time
Correct answer: while applying firm pressure to ensure good contact, wipe the connector end three
times
Question 12
When handling or working with circuit packs/modules, _____.
Your answer: foot/heel straps must be worn
Correct answer: wrist straps must be worn
Question 13
When inspecting and cleaning fiber/faceplate connections ______.
Your answer (correct): an optical power measurement should be made on the connector prior to
inspection and/or cleaning
Question 14
When inspecting bulkhead connectors, the ______ is recommended.
Your answer (correct): JDSU OLP-82 inspection scope
Question 15
The JDSU OLP-82 is classified as a ______.
Your answer (correct): remote viewing inspection scope
Question 16
When checking the optical power level at a fiber connector, it is important to make sure that the
measurement device is set up to show
Your answer (correct): dBm
Question 17
When transporting/storing circuit packs/modules, _____.
Your answer (correct): ESD safety container/bags should be used
Question 18
When using a Cletop cleaning stick, _____.
Your answer (correct): the cleaning stick should only be used once per connector
Question 19
When using a fiber inspection scope to inspect a fiber/bulkhead connection, _____.
Your answer (correct): the correct inspection adapter must be used
Question 20
When working in close proximity to telecommunications equipment, _____.
Your answer: ESD safety container/bags should be used

Correct answer: wrist straps should be worn