1.10 VARIO GT 24
Static values
PI 320 E 1/2
1.10 VARIO GT 24
Statische Werte
Extended static values for static analysis according to the load-resistance-factor design
Values of the design tables (permissible values) remain valid!
Characteristic stiffness
EI
887 kNm2
=
=
=
=
=
=
19.5 kN
42.0 kN
30.0 kN
10.5 kNm
10.5 kNm
6.0 kNm
this lues!
e:
t
n
o
o
N
ed ible va
n
o
i
ent ermiss
m
s
tp
lue
o
a
n
v
e
The eet ar
h
PI-S
The partial load factor M = 1.3 and the modication factor kmod = 0.9
have been taken into consideration in the rated value.
Permissible values are to be determined through division using the partial load factor F = 1.5.
Fm,End,R,d = 24.0 kN
Fn,End,R,d = 24.0 kN
LA
LA
min. 16 cm
min. 16 cm
LA
Fn,R,d = 42.0 kN
Mn,R,d = 10.5 kNm
LA
Responsible / Verantwortlich:
eMail:
2009-04-21 Lorenz PM
heiner.lorenz@peri.de
Fm,R,d = 30.0 kN
Mm,R,d = 6.0 kNm
Product Information
1.10 VARIO GT 24
Static values
PI 320 E 2/2
1.10 VARIO GT 24
Statische Werte
Bearing pressure
Reaction force FR,d = b Leff kc fc,R,d
b
Leff
= bearing width
= effective bearing length
= LA + 2 3 cm, but
2 LA
Material-conditioned coefcient for lateral pressure
support in the truss joints
kc,90,n = 1.45
support between the truss joints
kc,90,m = 1.0
Bearing pressure
fc,R,d = 1.88 N/mm
e2
e1
F1
Vq,red =
F2
LA
24
r l
2
Vq
e2 > 60cm : VF 2 = F2
l e1
e1
l
60cm
l e2
l
VF1
F1
q l L A 48cm
1
2
l
l
l e1
F V Vn,R,d = 24.0 kN
VF2
F2
l e2
Responsible / Verantwortlich:
eMail:
2009-01-27 Lorenz PM
heiner.lorenz@peri.de