You are on page 1of 11

PROJEK PENSWASTAAN LEBUHRAYA BERTINGKAT SUNGAI BESI - ULU KELANG

SECTION A - SUNGAI BESI TO CHERAS


PACKAGE : CA1 (CH.0 TO CH.2400)

BILL NO. 13 - STREET LIGHTING AND TRAFFIC LIGHT

ITEM DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT


NO. (RM) (RM)

(All quantities are subject to remeasurement)

13.1 STREET LIGHTING

13.1.1 Feeder Pillar

13.1.1.1 LV supply distribution feeder pillars (IP 54) nr 2


fabricated from electro-galvanised steel sheet with
minimum thickness of 2mm c/w padlock, switch
socket outlet with built-in ELCB, corrosive resistant
fluorescent light fitting, earthing equipment to Furse
(<1ohm) and concrete footing as per drawing. Heat
shrinkable sleeves and cable lugs must be used for
all cable terminations. Rate must also include
labelling, identification and connection of power
supply.

13.1.1.2 Street lighting feeder pillars (IP 54) fabricated from


electro-galvanised steel sheet with minimum
thickness of 2mm c/w padlock, switch socket outlet
with built-in ELCB, corrosive resistant fluorescent
light fitting, earthing equipment to Furse (<1ohm),
surge protection device and concrete footing as per
drawing. Heat shrinkable sleeves and cable lugs
must be used for all cable terminations. Rate must
also include labelling, identification and connection
of power supply.

a) Street Lighting Feeder Pillar nr 10

13.1.2 Cables

Rates shall include for the supply and pulling of


cables including trenching, sand bedding, jointing
of cables, backfilling, compaction, PVC slab,
orange nylon warning tape, disposal of surplus
material and making good of site surface as per
specifications.

13.1.2.1 4-core 300 sq.mm XLPE/SWA/PVC (Cu) cable


from Street Lighting Main Switch Borad to the LV
feeder pillar

a) LV Feeder pillar 1 m 700


b) LV Feeder pillar 2 m 700

Carried to Collection
PROJEK PENSWASTAAN LEBUHRAYA BERTINGKAT SUNGAI BESI - ULU KELANG
SECTION A - SUNGAI BESI TO CHERAS
PACKAGE : CA1 (CH.0 TO CH.2400)

BILL NO. 13 - STREET LIGHTING AND TRAFFIC LIGHT

ITEM DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT


NO. (RM) (RM)

13.1.2.2 4-core 240 sq.mm XLPE/SWA/PVC (Cu) cable


from Street Lighting Main Switch Borad or LV
feeder pillar to the Street Lighting Feeder Pillars

a) Feeder Pillar 'FP1' m 150

b) Feeder Pillar 'FP2' m 150

c) Feeder Pillar 'FP3' m 200

d) Feeder Pillar 'FP4' m 350

e) Feeder Pillar 'FP5' m 300

f) Feeder Pillar 'FP6' m 70

g) Feeder Pillar 'FP7 m 400

h) Feeder Pillar 'FP8' m 550

i) Feeder Pillar 'FP9' m 700

j) Feeder Pillar 'FP10' m 450

Carried to Collection
PROJEK PENSWASTAAN LEBUHRAYA BERTINGKAT SUNGAI BESI - ULU KELANG
SECTION A - SUNGAI BESI TO CHERAS
PACKAGE : CA1 (CH.0 TO CH.2400)

BILL NO. 13 - STREET LIGHTING AND TRAFFIC LIGHT

ITEM DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT


NO. (RM) (RM)

13.1.2.3
4-core 16 sq.mm PVC/SWA/PVC (Cu) street
lighting cable from Feeder Pillars to all lighting
columns:

a) Feeder Pillar 'FP1'


i) circuit a m 800

iI) circuit b m 850

iii) circuit c m 950

b) Feeder Pillar 'FP2'


i) circuit a m 600

iI) circuit b m 600

c) Feeder Pillar 'FP3'


i) circuit a m 850

iI) circuit b m 600

d) Feeder Pillar 'FP4'


i) circuit a m 800

iI) circuit b m 850

e) Feeder Pillar 'FP5'


i) circuit a m 600

iI) circuit b m 500

iii) circuit c m 600


f) Feeder Pillar 'FP6'
i) circuit a m 550
iI) circuit b m 250

iii) circuit c m 600


iv) circuit d m 450
v) circuit e m 450
g) Feeder Pillar 'FP7'
i) circuit a m 600

iI) circuit b m 550

iii) circuit c m 600

iv) circuit d m 350


Carried to Collection
PROJEK PENSWASTAAN LEBUHRAYA BERTINGKAT SUNGAI BESI - ULU KELANG
SECTION A - SUNGAI BESI TO CHERAS
PACKAGE : CA1 (CH.0 TO CH.2400)

BILL NO. 13 - STREET LIGHTING AND TRAFFIC LIGHT

ITEM DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT


NO. (RM) (RM)

h) Feeder Pillar 'FP8'


i) circuit a m 300

iI) circuit b m 550

i) Feeder Pillar 'FP9'


i) circuit a m 600

iI) circuit b m 500

j) Feeder Pillar 'FP10'


i) circuit a m 400

iI) circuit b m 300

iii) circuit c m 300

13.1.2.4
2-core 2.5 sq.mm PVC/SWA/PVC (Cu) dimming
cable from Feeder Pillars to all lighting
columns/junction boxes.

a) Feeder Pillar 'FP1'


i) circuit a m 800

iI) circuit b m 850

iii) circuit c m 950

b) Feeder Pillar 'FP2'


i) circuit a m 600

iI) circuit b m 600

c) Feeder Pillar 'FP3'


i) circuit a m 850

iI) circuit b m 600

d) Feeder Pillar 'FP4'


i) circuit a m 800

iI) circuit b m 850

Carried to Collection
PROJEK PENSWASTAAN LEBUHRAYA BERTINGKAT SUNGAI BESI - ULU KELANG
SECTION A - SUNGAI BESI TO CHERAS
PACKAGE : CA1 (CH.0 TO CH.2400)

BILL NO. 13 - STREET LIGHTING AND TRAFFIC LIGHT

ITEM DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT


NO. (RM) (RM)

e) Feeder Pillar 'FP5'


i) circuit a m 600

iI) circuit b m 500

iii) circuit c m 600

f) Feeder Pillar 'FP6'


i) circuit a m 550

iI) circuit b m 250

iii) circuit c m 600

iv) circuit d m 450

v) circuit e m 450

g) Feeder Pillar 'FP7'


i) circuit a m 600

iI) circuit b m 550

iii) circuit c m 600

iv) circuit d m 350

h) Feeder Pillar 'FP8'


i) circuit a m 300

iI) circuit b m 550

i) Feeder Pillar 'FP9'


i) circuit a m 600

iI) circuit b m 500

j) Feeder Pillar 'FP10'


i) circuit a m 400

iI) circuit b m 300

iii) circuit c m 300

Carried to Collection
PROJEK PENSWASTAAN LEBUHRAYA BERTINGKAT SUNGAI BESI - ULU KELANG
SECTION A - SUNGAI BESI TO CHERAS
PACKAGE : CA1 (CH.0 TO CH.2400)

BILL NO. 13 - STREET LIGHTING AND TRAFFIC LIGHT

ITEM DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT


NO. (RM) (RM)

13.1.2.5 Trench excavation for laying of the above cables


c/w sand bedding, intermediate joints,
backfilling,compaction, PVC slab, orange
nylon warning tape, disposal of surplus
material and making good of site surface
as per specifications.

a) 400 (W) X 1400 (D) for all above cables m 31900

13.1.2.6 2 core 2.5 sq.mm XLPE/SWA/PVC (Cu) cable


from Feeder Pillars to remote photo cell on
nearest column.

a) Feeder Pillar 'FP1' m 30


b) Feeder Pillar 'FP2' m 30
c) Feeder Pillar 'FP3' m 30
d) Feeder Pillar 'FP4' m 30
e) Feeder Pillar 'FP5' m 30
f) Feeder Pillar 'FP6' m 40
g) Feeder Pillar 'FP7' m 30
h) Feeder Pillar 'FP8' m 30
i) Feeder Pillar 'FP9' m 30
j) Feeder Pillar 'FP10' m 20

13.1.2.7 3-core 4 sq.mm XLPE/SWA/PVC (Cu)


soffit lighting cable from junction box to
all soffit lighting:
a) Feeder Pillar 'FP KESAS'

i) circuit a m 100

ii) circuit b m 100

13.1.2.8 HDPE (PN10) ducts laid by Horizontal Direct


Drilling method including provision,assembly and
removal of completion of all plant, equipment,
resources, and temporary works, complete with
nylon draw rope, excavation of pit, backfilling,
disposal of surplus materials, breaking up existing
pavement and reinstatement of surfaces

a) 150mm Diameter HDPE (PN10) (2 way) m 250


b) 150mm Diameter HDPE (PN10) (4 ways) m 40
c) 150mm Diameter HDPE (PN10) (8 ways) m 30

Carried to Collection
PROJEK PENSWASTAAN LEBUHRAYA BERTINGKAT SUNGAI BESI - ULU KELANG
SECTION A - SUNGAI BESI TO CHERAS
PACKAGE : CA1 (CH.0 TO CH.2400)

BILL NO. 13 - STREET LIGHTING AND TRAFFIC LIGHT

ITEM DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT


NO. (RM) (RM)

Underground Ducts

13.1.2.9 Rates shall include for the supply and laying of


underground ducts including trenching, jointing
(using proper collars), backfilling, compaction,
crossing markers, draw-in wire, disposal of surplus
material and making good of site surface as per
specifications.
a) 1 no. 100 mm dia. GI pipe class 'B' m 50
a) 2 no. 100 mm dia. GI pipe class 'B' m 50
a) 3 no. 100 mm dia. GI pipe class 'B' m 50
a) 4 no. 100 mm dia. GI pipe class 'B' m 100

13.1.2.10 Trench excavation for laying of the above


GI ducts c/w sand bedding, backfilling,
compaction, disposal of surplus material and
making good of site surface
as per specifications.
a) 400 (W) X 1300 (D) for all above GI ducts m 250

Ducts at Bridge

13.1.2.11 Supply and install 2 nos. of 150mm dia. m 200


corrugated double wall HDPE ducts
(spare included) for cables at the bridge
crossing KESAS Highway. Ducts are to be laid
inside the bridge U-beam section and to be
secured by galvanised iron tape every 2m.

Lighting Columns
13.1.2.12 Rates shall include for all operations necessary for
a) 12 meter high tapered octogonal single-section
i) Single sided 3 meter arm nr 375
ii) Double sided 3 meter arm nr 6

Lighting Column Foundation


13.1.2.13 Supply and install concrete foundation for lighting nr 381
columns whose rate must include submission of
design calculations, pipe sleeves, reinforcements,
high tensile grout, etc.

Feeder Pillar Foundation

13.1.2.14 Supply and install concrete foundation for feeder nr 12


pillar whose rate must include submission of
design calculations, pipe sleeves, reinforcements,
high tensile grout, etc.

Carried to Collection
PROJEK PENSWASTAAN LEBUHRAYA BERTINGKAT SUNGAI BESI - ULU KELANG
SECTION A - SUNGAI BESI TO CHERAS
PACKAGE : CA1 (CH.0 TO CH.2400)

BILL NO. 13 - STREET LIGHTING AND TRAFFIC LIGHT

ITEM DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT


NO. (RM) (RM)

Luminaire

13.1.2.15 Supply and install and connect the following IP66


LED luminaire c/w LEDs, main ballast, surge
protection device, AC drivers and all mounting
accessories and earthing as per specifications and
drawings:

(Catalogues showing isolux diagram, utilization


factor curves, polar curves,
downward light output
ratio and computer generated print-outs
showing all the calculation results of the light
distribution on the road surface using the
luminaire offered shall be enclosed. Failure to
submit the above may render the tender
submission null and void)

1 X 221W LED Street Lantern ,IP66 c/w control nr 387


gears, etc. to Schreder Teceo 2 or approved
equivalent (Provisional)

13.1.2.16 High quality luminaire suitable for underpass


lighting with:
a) Asymmetrical light distribution.
b) Clear SON-T lamp
c) Ignitor, capacitor, ballast and lamp.
d) Index Protection of at least IP 65
e) Dimming control circuit c/w dimming ballast
f) Lamp holder with anti-vibration fixation device.
g) Complete mounting accessories.
h) GI conduits from the junction box to the
luminaire.

(Catalogues showing isolux diagram, utilization


factor curves, polar curves of C-planes 0-180,
90-270, 15-65 degrees, downward light output
ratio and computer generated print-outs
showing all the calculation results of the light
distribution on the road surface using the
luminaire offered shall be enclosed. Failure to
submit the above may render the tender
submission null and void)

a) 250 W HPSV soffit lighting to Schreder nr 6


RT3 or approved equivalent.

Carried to Collection
PROJEK PENSWASTAAN LEBUHRAYA BERTINGKAT SUNGAI BESI - ULU KELANG
SECTION A - SUNGAI BESI TO CHERAS
PACKAGE : CA1 (CH.0 TO CH.2400)

BILL NO. 13 - STREET LIGHTING AND TRAFFIC LIGHT

ITEM DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT


NO. (RM) (RM)
Miscellaneous

13.1.2.17 Photo cell sensors nr 10

13.1.2.18 Earthing of every lighting columns nr 381


to achieve less than 5 ohm which must
include copper tape, inspection pit,
accessories, copper rod to Furse or
approved equivalent.

13.1.2.20 Labelling of all columns including feeder pillars with nr 393


reflective stickers to 3M or approved equivalent in
accordance to the initial and numberings as per
drawing.

13.1.2.21 LS
Submission of shop drawings, samples,
catalogues, etc. for approval.

13.1.2.22 Factory acceptance test of luminaires at the place LS


of manufacture/assembly including passage,
lodging, etc for 4 persons.

13.1.2.23 Factory acceptance test of columns at the place of LS


manufacture including passage, lodging, etc for 4
persons.

13.1.2.24 Allow sum for sending the light fitting for an LS


independent laboratory test other than SIRIM to
test the following features:-
a) Photometrics
b) IP rating

13.1.2.25 LS
5 sets of as-built drawings in plastic pockets in
hard cover files and CD ROM.

13.1.2.26 5 sets of operation and maintenance manuals in LS


plastic pockets in hard cover files.

13.1.2.27 Scheduled monthly maintenance of the whole LS


street lighting installation for 24 months. Tenderer
to submit details of maintenance method
statement.

Carried to Collection
PROJEK PENSWASTAAN LEBUHRAYA BERTINGKAT SUNGAI BESI - ULU KELANG
SECTION A - SUNGAI BESI TO CHERAS
PACKAGE : CA1 (CH.0 TO CH.2400)

BILL NO. 13 - STREET LIGHTING AND TRAFFIC LIGHT

ITEM DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT


NO. (RM) (RM)

13.1.2.28 Testing and commissioning of the whole street LS


lighting installation which among other things
must include:-
a) Light distribution test using lux meter as well
as photometer.

b) Megger test of all cables including


pole-to-pole megger test.
c) Verticality check on the columns using
theodolites.
d) Earth resistance test on all earth chambers.

13.1.2.29 Allow a Provisional Sum of RM 1,500,000.00 LS


to be paid to TNB as Contribution Charges
for the laying of power supply cables, metering
meter deposit and any other fees deemed
necessary by TNB.

13.1.2.30 Spare parts:

a) 12m street lighting column with single sided nr 20


3m arm

b) 12m street lighting column with double sided nr 1


3m arm

d) 221 W LED Lantern nr 20

e) Photo cell nr 1

Carried to Collection
PROJEK PENSWASTAAN LEBUHRAYA BERTINGKAT SUNGAI BESI - ULU KELANG
SECTION A - SUNGAI BESI TO CHERAS
PACKAGE : CA1 (CH.0 TO CH.2400)

BILL NO. 13 - STREET LIGHTING AND TRAFFIC LIGHT

ITEM DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT


NO. (RM) (RM)

COLLECTION PAGE

BQ 13. - 1/11

BQ 13. - 2/11

BQ 13. - 3/11

BQ 13. - 4/11

BQ 13. - 5/11

BQ 13. - 6/11

BQ 13. - 7/11

BQ 13. - 8/11

BQ 13. - 9/11

BQ 13. - 10/11

TOTAL CARRIED TO SUMMARY