CALCULATIONFORSHOPSPLICINGOFSWAYGIRDERFORHTMJ2+3
Section of sway bracing= ISA110x110x10
Section properties
Ix = 240 cm4
Zx = 30.4 cm3
A= 21.1 cm2
r1 3.37
fy = 250 N/mm2
Partial Safety Factor= 1.25 (for Ultimate stress, refer table 5 of IS80

DesignofSplicePlates

Design Ultimate Tension / Comp stress (fa)= fy / SF


Design Ultimate Axial Capacity of Section (T)= A x fa
Splice to be Designed for Capacity (Percentage)
So, Ultimate Axial force for Splice Plate Design
Splice Design Force is taken by one side of angles (F)

DesignofSplicePlates
Total available width for splice (Bfp) 110-2x20
Thickness of flange splice plate reqd F / (Bfp x fa)
Flange Splice plate thk provided

Ultimate Strength of Weld (Refer IS:814)


Type of weld
Partial Safety factor of Weld (Refer Table 5 of IS 800) (FS )
Design Ultimate shear strength of weld fuw / sqrt(3) / FS
Size of weld
Capacity of weld per unit length 0.707 x 8 x 189 / 1000
Required total weld length 221.55/1.071
Weld Length each side 206.8/2
Length of flange splice plates required 2x103.42
Length of flange plates Provided
Size of splice plate provided = 16x70x275
, refer table 5 of IS800 )

= 200 N/mm2
= 422 KN
= 105%
= 443.1 KN
= 221.55 KN

= 70 mm
= 15.83 mm
= 16 mm

= 410 N/mm2
= Shop
= 1.25
= 190 N/mm2
= 8 mm
= 1.072 KN/mm
= 206.60 mm
= 103.30 mm
= 206.60 mm
= 275 mm