DESIGN OF FOUNDATION FOR COLUMN OF COMPOUND WALL (CITY PLOT)

C/L of footing
C/L OF FOOTING
2200

810 290

2200

Axial Load form staad =71 kN

Moment = 41kNm footing at depth of 1.4m below NGL

C/C dist b/w column center line & footing center line = 0.29m

Weight of soil above Foundation =2.2x2.2x1x18 (1m depth of soil above foundation)
= 87.12 kN

Weight of Foundation = 2.2x2.2x.4x25=48.4kN

Total Axial load =71+87.12+48.4 = 206.62 KN

Additional moment due to Eccentricity = 71X0.29=21kNm

Total moment = 41+21=61 kNm

M 61
Eccentricity of loading (e) = 0.29m
P 206.62

e <L/6(L/6=0.366m).

P 6e
Since e < L/6 qmax,min= (1 ) .
A L

206.62 6 x0.29
qmax= (1 ) =76.5kN/m2
2.2 x2.2 2.2
206.62 6 x0.29
qmin= (1 ) =8.92kN/m2
2.2 x 2.2 2.2

Bending moment calculation:-

810 1390

8.92 kN/m

76.5kN/m
2
44.7kN/m

44 .7 x1.165 2 1 2
Max B.M at the face of the column = x(76 .5 44 .7) x1.165 x x1.165 =44.72kNm
2 2 3

0.5x30 4.6 x1.5x44.7 x106


Ast = [1 1 ]x1000x340 (cover for footing=60mm)
500 30 x1000x3402

=465 mm

Providing y12- 200 b/w bottom steel


Check for one way shear

Base pressure at dist of d from face of column=8.92+(0.805x67.58/2.2)=33.65kN/m2

Shear force at a dist d form face of column

810

225 352 805

233

Max S.F =33.65 x0.805+0.5x(76.5-33.65)x0.805=44.4kN

44 .4 X 10 3
TV= =0.13x1.5=0.19
1000 X 340

3.14 1000
Ast provided = x122 x =565.2mm
4 200

565.2
Pt = x100 =0.16%
1000x340

Tc= 0.29; TV< Tc hence safe

Check for 2 way shear

Ast a dist d/2 form face of column


790

640
Pu 1.5 x 207
Wu = = =64.15 kN/m
A 2 .2 x 2 .2

Punching shear =64.15x ( ) KN

278 x10 3
TV = =0.27
2[790 640 ] x352

0.3
Ks = min (0.5 ) ;1
0.45

Ks = 1

Tc = Ks x0.25 30 =1.36

= TV< Tc hence safe


STABILITY CRITERIA

Earth pressure = KarH

= 0.33x18x1.4 =8.316 kN/m

wind load form calculation =7.728kN/m

7.728kN/m 2400

1000

400

8.316kN/m

Axial load from staad = 70 kN ( Excluding soil weight and weight of footing)

70 KN will act at centre of column

Weight of soil =2.2x2.2x1x18 =87.12 kN will out at centre of footing

Weight of footing =2.2x2.2x25 = 121 kN will out at centre of footing

Total dead weight = 121+87.12+70 =278.12 = 279 kN

Normal due to wind load from staad =41kNm

Normal due to Earth Pressure =8.316x1.4x0.5xx(1.4)

=2.45kNm

810 1390

W1 W3

W2

Q A
Sr.No Designation Force(kN) Lever arm Moment at (A)kNm
1 w(DL from 71 1.390 97.3 kNm
staad)
w (S.W of (2.2x2.2x0.4x25)=48.4 1.1 53.24 kNm
footing)
2
3 w(S.W of soil (2.2x2.2x1x18)=87.12 1.1 95.8 kNm
above footing)
206.52 kN 246.372 kNm

246 .372
F.O.S against overturning = =5.67 > 1.5 safe
(2.45 41)

206.52x0.4 5
F.O.S against sliding =
(7.728x2.4 + x8.316x1. 4x0.33x(1. 4))

=4.345>1.5 safe

(coeff of friction)=0.45 considered for coarse grained soil with silt


Design of 230 thk brick wall for wind load

Clear Height of Brick wall = 1.84m

Clear Length of Brick wall = 4.9-0.3=4.6m

Check for slenderness

Safe as for table 7 IS 1905

K =1.0; considering as permanent structure with design life 50 years

K= considering class A & category 2=1

K =Topography factor taken as 1

Design wind speed =50x1x1x1=50m/s

P=0.6x50=1.5KN/M

Force co-eff as per table 24-IS-875-part 3 for b/h= =2.5 &one edge on ground is 1.2

Panel load on wall =1.5x1.2x1.84x4.6=15.2 kN

U.D.L due to self weight =0.23x1.84x18=7.61 kN/m

Compressive strength = =0.033

Bending moment for H/L =0.4= as per table 14 IS 1905 -1987

M =- kNm

Section modulus(Parallel to bed joint) ZH= =16.22x10 mm3

Bending strength due to wind (Parallel to bed joint) = =0.079


Section modulus(Perpendicular to bed joint) ZL= =40.55x10 mm3

Bending strength due to wind (Perpendicular to bed joint) = =0.0318

Now,

Max comp stress (Parallel to bed joint) =0.079+0.033

=0.112 N/mm

For M1 grade Masonry with C.M Proportion 1:5 (corresponding to masonry strength of 5 N/mm)

Max Comp stress as per table 8 is 0.5 N/mm

0.112<0.5 N/mm (safe)

Max tensile stress (Parallel to bed joint) =0.079-0.033

=0.046<0.14(safe)

As per cl 5.4.2 IS 1905

Now, max comp stress (Perpendicular to bed joint) =0.0318+0.33

= 0.3618 < 0.5 N/mm (safe)

Now, max com stress (Perpendicular to bed joint) =0.0318-0.33

=-0.29<0.07 N/mm (safe)

As per 5.4.2 IS 1905