SITE ADDRESS:

746 NEW SOUTH HEAD RD


ROSE BAY NSW 2029
DRAWING LIST (PROJECT NO. 160509) - EARLY WORKS PACKAGE
NO. SHEET NO. SHEET NAME SIZE REV ISSUED DATE

1 S001 COVER SHEET A1 B 26.04.2017


2 S100 GENERAL NOTES A1 A 21.02.2017
3 S200 SCREW PIER SETTING OUT PLAN A1 A 21.02.2017
4 S300 FLOOD PROTECTION SHELL PLAN A1 B 03.03.2017
5 S301 FLOOD PROTECTION SHELL SECTIONS A1 B 26.04.2017
6 S302 FLOOD PROTECTION SHELL PLAN & DETAILS A1 B 26.04.2017
7 S303 WALL LAYOUT - BELOW GROUND FLOOR A1 B 26.04.2017
8 S305 FLOOD PROTECTION SHELL REINFORCEMENT PLAN A1 B 26.04.2017
9 S306 FLOOD PROTECTION SHELL REINT. SECTION A1 B 26.04.2017
DETAILS
10 S601 GROUND LEVEL PLAN AND SECTIONS A1 A 26.04.2017
11 S602 LEVEL 1 PLAN AND SECTIONS A1 A 26.04.2017
12 S603 LEVEL 2 PLAN AND SECTIONS A1 A 26.04.2017
13 S604 ROOF PLAN AND SECTIONS A1 A 26.04.2017
14 S605 GROUND LEVEL REINF. PLAN AND SECTIONS A1 A 26.04.2017
15 S606 LEVEL 1 REINFORCEMENT PLAN AND SECTIONS A1 A 26.04.2017
16 S607 LEVEL 2 REINFORCEMENT PLAN AND SECTIONS A1 A 26.04.2017
17 S608 ROOF LEVEL REINFORCEMENT PLAN-AND A1 A 26.04.2017
SECTIONS
18 S609 AWNING DETAILS A1
19 S701 SECTIONS & DETAILS - 01 A1 A 26.04.2017
20 S702 SECTIONS & DETAILS - 02 A1 A 26.04.2017
22 S901 STAIRS DETAILS A1 A 26.04.2017

FOR TENDER
GOOD FOR CONSTRUCTION
REVISIONS & AMENDMENTS
REV. DESCRIPTION DATE SAFE AUSTRALIA PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE
A ISSUED FOR TENDER 10.03.2017 DESIGN & CONSULTING ENGINEERS 746 NEW SOUTH HEAD RD 160509 BT 10.03.2017 26.04.2017
B RE-ISSUED FOR TENDER 26.04.2017 CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT
SUITE 7, 8 MCFARLANE STREET
ROSE BAY NSW 2029 APPROVED BY CHECKED BY SHEET SIZE SCALE
MERRYLANDS, NSW 2160, Australia AN VR A-1 1:100
P: 02 8872 4902
M: 04 3734 2436 DRAWING CONTENT CLIENT DRAWING NO. REVISION
E: contact@safeoz.com.au
www.safeoz.com.au
AZHAR M. NASIR
MIEAust, CPEng, NPER, (2016938)
COVER SHEET 746 OSH PTY LTD S001 B
DD EE
S301 S301
A
CC
S301
CAPPING BEAM TOP LEVEL=3.800 CAPPING BEAM TOP LEVEL=4.400
SEWER MAIN: 4.2m OFF REAR
BB S301
LEGEND:

0
S301 300 BORED PIERS WITH 50MM GAP (TBC) PIPES CAST IN SLAB

45
0
BOUNDARY WALL 2.9m TO INVERT
0

30
FPS WALL 250MM THK CAPPING BEAM TOP LEVEL=5.330
+0.700 45

1000
SEA WALL S500 450 CFA PIER SHORING WALL
BY 550
AA1 OTHERS 0
S300
1 +0.900 CC2 30
S500 300 CFA PIER SHORING WALL

CC1 -0.050 450 CFA PIERS


4230 S500 WITH 50MM GAP 168 SCREW PIERS
+1.750 CAPPING BEAM TOP LEVEL=5.080
FPS WALL 250MM THK
ENCASED STORM WATER PIPE S500
250MM THK R.C WALL (u.n.o)

2 CC1, CC2: RC COLUMNS


+0.250 ACCESS OPENING 900X900
9825

ENCASED SEWER CAPPING BEAM TOP LEVEL=3.400


S500 +0.690
2400

+1.200 S500 +4.000


+3.945
350
AA S500 F S600
S300
3 S301

ENCASED STORM WATER PIPE


3195

4%
VARIES

ABSORBTION PIT
4
1000

OPENING FOR FLOOD SEALED 100MM THK SHOTCRETE WITH SL82 MESH &
REFER TO SEAWALL GATE N12 DOWEL @ 1500 C/C HORIZONTAL AND 1200 C/C VERTICAL
CONSULTANT'S DOCUMENTS DOWELS DRILLED & FIXED TO PIERS 120MM EMBEDMENT.
G2
SEWER MAIN: 5.35m OFF REAR

4%
S301
BOUNDARY WALL 2.95m TO INVERT
B

13690 10210 7000 5840 4820 2350 6450


50360
+4.565~+4.850
GROUND LEVEL S250
A B C D E F G H
CAPPING BEAM TOP LEVEL=3.400
FPS FLOOR PLAN
G1
NOTE: WORK METHOD CAN BE (i) SERVICE UNINTERRUPTED OR
(ii) SERVICE INTERRUPTED. S301
IF SERVICE WOULD BE REQUIRED UNINTERRUPTED, SCALE 1 : 100
THEN DIG IN ONE THIRDS OF THE LENGTH, STARTING ALL WALLS AND SLABS ARE N50 CONCRETE, 250MM THICK. 5
FROM MIDDLE, AND HAVE SUFFICIENT WORKABLE 1 REFER TO DWG S302 FOR GROUND FLOOR SUPPORTS.
SPACE TO POUR CRONCRETE. 1 GROUND FLOOR SUPPORTS SHOULD BE CAST TOGETHER WITH FPS SLAB WHERE APPLICABLE.
2 2 5700
B A C D E F G H
J K
450

0.3mm VAPOUR BARRIER B


20MM THK FLEXIBLE WRAP TO ALLOW N10-300 TIES CAPPING BEAM WALL TOP HEIGHT TO BE EQUAL TO
PIPE EXPANSION CONTRACTION 3N12 MAIN BARS EACH FACE OR HIGHER THAN GROUND LEVEL BEFORE NEIGHBOUR RETAINING
DUE TO TEMPERATURE CONDITION 450 4.800 4.800 EXCAVATION.
50mm LEAN CONCRETE WALL
4.030
SEWER PIPE ENCASEMENT DETAILS 3.945
550X400 CAPPING
SCALE 1 : 20 3.400 BEAM

2.500
EXTERNAL GROUND LEVEL EXTERNAL GROUND LEVEL PERMEATION GROUTING
1.675 1.750 1.660 1.720 1.720
1.200 1.200
0.690
0.250

SEA WALL
BY OTHERS 450 CFA PIERS WITH 50MM GAP
SEWER MAIN 2
TO INVERT 100MM THK SHOTCRETE WITH SL82 MESH &
S300 N12 DOWEL @ 1500 C/C HORIZONTAL AND 1200 C/C VERTICAL
REFER TO REPORT BY DOWELS DRILLED & FIXED TO PIERS 120MM EMBEDMENT.
ALL SYDNEY SIDE LINES PTY LTD
DATED 16/06/2015

B
SECTION AA
A B C SCALE 1 : 100 S602 D E F G H

5.330

550WX400D CAPPING BEAM


4.400
3.800
100MM THK SHOTCRETE WITH SL82 MESH &
N12 DOWEL @ 1500 C/C HORIZONTAL AND 1200 C/C VERTICAL
2.500 DOWELS DRILLED & FIXED TO PIERS 120MM EMBEDMENT.
EXTERNAL GROUND LEVEL
1.750
1.200 450 CFA PIERS WITH 50MM GAP
0.700

MIN.2000
FPS FLOOR 500MM
ENCASED STORM WATER PIPE
SEA WALL
BY OTHERS NOTE: CAPPING BEAM TOP LEVEL SHALL BE EQUAL
SEWER MAIN TO OR HIGHER THAN GROUND LEVEL BEFORE
EXCAVATION.

FOR TENDER
SECTION AA1 GOOD FOR CONSTRUCTION
SCALE 1 : 100 S300
REVISIONS & AMENDMENTS
REV. DESCRIPTION DATE SAFE AUSTRALIA PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE
A ISSUED FOR TENDER 21.02.2017 DESIGN & CONSULTING ENGINEERS 746 NEW SOUTH HEAD RD 160509 BT 03.03.2017 03.03.2017
B SEWER ENCASEMENT DETAIL ADDED 03.03.2017 CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT
SUITE 7, 8 MCFARLANE STREET
ROSE BAY NSW 2029 APPROVED BY CHECKED BY SHEET SIZE SCALE
MERRYLANDS, NSW 2160, Australia AN VR A-1 1:100
P: 02 8872 4902
M: 04 3734 2436 DRAWING CONTENT CLIENT DRAWING NO. REVISION
E: contact@safeoz.com.au
www.safeoz.com.au
AZHAR M. NASIR
MIEAust, CPEng, NPER, (2016938)
FLOOD PROTECTION SHELL PLAN 746 OSH PTY LTD S300 B
1 2 3 4 1 2 3 4 1 2 3 4

LEGEND:
3.800 ACCESS OPENING 600X900
300 BORED PIERS WITH 50MM GAP 120MM AFS LOGICWALL
2.750 2.750
2.750 2.750 FPS WALL 200MM THK FPS WALL 200MM THK 2.750 2.800
FPS FLOOR 500MM
GROUND FLOOR 150MM AFS LOGICWALL
FPS WALL 200MM THK GROUND FLOOR 1.750
FPS FLOOR 500MM RL 1.800 1.750

LEVEL
MIN 2M SOCKETING
1.470 RL 1.800 1.200 GROUND FLOOR RL 1.800
1.200 GROUND FLOOR 1.200 1.200 GROUND FLOOR 162MM AFS LOGICWALL
0.900
0.690

BELOW 1.75M
0.250 FPS FLOOR 500MM
RL 0.250 200MM AFS LOGICWALL

.
RL 0.250 PUMPOUT PIT RL 0.250
PUMPOUT PIT PUMPOUT PIT
WALL UNDER
ENCASED STORM WATER PIPE
PERMEATION GROUTING
PERMEATION GROUTING
PERMEATION GROUTING

SECTION BB SECTION CC SECTION DD


SCALE 1 : 100 S300 SCALE 1 : 100 S300 SCALE 1 : 100 S300

N12-1200(V)
N12-1000(H)
DOWELS (EPOXY ANCHORING TO SPECIALISTS DETAILS)
1 2 3 4
J K 5

RL 4.850
410 (MIN)

4.400
550WX400D CAPPING BEAM LEVEL 1
1 4.000
4% EXTERNAL GROUND LEVEL
450 CFA PIERS WITH 50MM GAP 4% EXTERNAL GROUND LEVEL N12-400(V)
S301
250MM THK SLAB+4.565~+4.850
600

500 250MM THK SLAB ON PIER CAP LAPBARS


200

2.750 VERTICALLY
(MIN 300 LEG)
1.750 PIER CAP
LEVEL
MIN 2M SOCKETING

1.650 ABSORPTION PIT(NO SLAB) RL 1.800 PIER CAP 600X600X600


600X600X600 168 SCREW PIERS
GROUND FLOOR
168 SCREW PIERS SL 82 MESH
BELOW 1.75M

500MM THK SLAB 40 COVER


.

RL 0.250
PUMPOUT PIT
PERMEATION GROUTING

SECTION EE SECTION G1 SECTION G2


SCALE 1 : 100 S300 SCALE 1 : 100 S300 SCALE 1 : 100 S300
140

140
200

200

WALL/SLAB
350

WATER STOP BAR TO ENGINEER'S APPROVAL


500

4N16 VERTICAL BARS WALL/SLAB WATER STOP BAR TO ENGINEER'S APPROVAL CONSTRUCTION JOINT
N10. 250 TIES
4N24 VERTICAL BARS
N10. 250 TIES 300 CFA PIERS WITH 50MM GAP
CONSTRUCTION JOINT
100 THK SHOTCRETE WITH SL82 MESH
450 CFA PIERS WITH 50MM GAP & N12 DOWEL @ 1500 c/c HORIZONTAL
AND 1200 c/c VERTICAL DOWELS DRILLED & TYPICAL CONSTRUCTION JOINT TYPICAL CONSTRUCTION JOINT AFS162
100 THK SHOTCRETE WITH SL82 MESH FIXED TO PIERS 120MM EMBEDMENT.
& N12 DOWEL @ 1500 c/c HORIZONTAL
HIGH STRENGTH
(HORIZONTAL) (VERTICAL) 100 THK SHOTCRETE WALL
AND 1200 c/c VERTICAL DOWELS DRILLED & 550WX400D CAPPING BEAM
FIXED TO PIERS 120MM EMBEDMENT. MORTAR NOTE: CONSTRUCTION JOINT LOCATIONS SHOULD BE APPROVED BY THE ENGINEER NOTE: CONSTRUCTION JOINT LOCATIONS SHOULD BE APPROVED BY THE ENGINEER
HIGH STRENGTH
100
MORTAR
DETAIL A 450 CFA PIERS WITH 50MM GAP
SCALE 1 : 20 S300
100 100MM THK SHOTCRETE WITH SL82 MESH &
N12 DOWEL @ 1500 C/C HORIZONTAL AND 1200 C/C VERTICAL

TYPICAL SHORING PIER WALL TYPICAL SHORING PIER WALL DOWELS DRILLED & FIXED TO PIERS 120MM EMBEDMENT.

B DETAIL 1
550 400 SCALE1 : 30
400x550 WIDE CAPPING BEAM WITH 4N16 FACEBARS 400x400 WIDE CAPPING BEAM WITH 4N16 FACEBARS 350 2645 3275 250
FPS WALL 250MM THK
+ 2N12 T&B BARS N10-300 TIES, 50 COVER TO TIES + 2N12 T&B BARS N10-300 TIES, 50 COVER TO TIES
400

400

RL 1.800
1.675 GROUND FLOOR 2-N16 DOWELS T&B PER PIERS (TYP.)

FLOOR
250

100 THK. SHOTCRETE WALL 100 THK. SHOTCRETE WALL


225

1.200
500

TBC TBC
CHIP 50MM DEEP
N12-200 SQUARE CUT GROOVE
450 100 300 100 800 AT SLAB LEVEL TO CONNECT
SLAB TO PIERS (TYP.)
BARS TYP.
TYPICAL CAPPING BEAM DETAILS TYPICAL CAPPING BEAM DETAILS ALONG THE
PERIMETER DETAIL 2
(450 CFA PIER) (300 CFA PIER) SCALE 1 : 20 FOR TENDER
SECTION F
SCALE 1 : 20 S300
GOOD FOR CONSTRUCTION
REVISIONS & AMENDMENTS
REV. DESCRIPTION DATE SAFE AUSTRALIA PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE
A ISSUED FOR TENDER 21.02.2017 DESIGN & CONSULTING ENGINEERS 746 NEW SOUTH HEAD RD 160509 BT 21.02.2017 26.04.2017
B RE-ISSUED FOR TENDER 26.04.2017 CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT
SUITE 7, 8 MCFARLANE STREET
ROSE BAY NSW 2029 APPROVED BY CHECKED BY SHEET SIZE SCALE
MERRYLANDS, NSW 2160, Australia AN VR A-1 1:100
P: 02 8872 4902
M: 04 3734 2436 DRAWING CONTENT CLIENT DRAWING NO. REVISION
E: contact@safeoz.com.au
www.safeoz.com.au
AZHAR M. NASIR
MIEAust, CPEng, NPER, (2016938)
FLOOD PROTECTION SHELL SECTIONS 746 OSH PTY LTD S301 B
F G
E E1 S702 S702 LEGEND:
D S702 S702
S702 120MM AFS LOGICWALL

150MM AFS LOGICWALL


1
162MM AFS LOGICWALL
30
+4.800 200MM AFS LOGICWALL

1456
CC1 SC2 S275
CC2
4230

C
+4.770 WALL UNDER
+4.770 S702
+4.725 S170
SC1 30 S170
S200 SLAB CUT-OUT
200x500
150x600
2 ACCESS OPENING 900X900
Sxxx xxx THK SLAB
75 200x1115
9825

+4.800
+4.710
5
SC1 150x50 SOLID BAR STEEL COLUMN
S200 300x550
2400

+4.000
+3.945
B S200
90
S601 +4.030 85 SC2 150x150 SOLID BAR STEEL COLUMN
S701 30 S200 S600
8
3 S602 SC3 SC3 100x100 SOLID BAR STEEL COLUMN

60
SC1 +4.770 +4.770 SC4 250 UC 89 STEEL COLUMN
30 S170 S170
7
SC3
3195

S602
A
1050

4%
VARIES SC4
S701

4 9
S602 3
S602

4%
13690 10210 7000 5840 4820 2350 6450 6330
50360 +4.565~+4.850
S250

A B C D E F G H

H
LEVEL 1 PLAN-POST TENSIONED
SCALE 1 : 100 5
FOR SLAB THICKNESS REFER TO PTC DRAWINGS
SC4 5700

1020

20
73
J K

75
G

296
236
B
3.945

75
4.800 RL 4.850

200
4.800 4.710 LEVEL 1
RL 4.850

73
200

4.725

170
LEVEL 1

2010
200

20
345
275
200

30 75 75 30
210
150 120 3.145 6-M16 HOLDING DOWN BOTLS DRILLED FIXED USING EPOXY GROUT
575
REO 502 RAMSET OR EQUIVALENT 120MM MIN EMBEDMENT

SECTION 7 SECTION 8 SECTION 9


8 THK BASE PLATE PLACED ON
20MM THK GROUT BELOW BASE PLATE
SCALE 1 : 20 S602 SCALE 1 : 20 S602 SCALE 1 : 20 S602 SCALE 1 : 5

SC1(O)
2-N24 CROSS BARS
SC2(O)
600MM LONG
4.800 RL 4.850
4.725 LEVEL 1
75

250x250x20 THK PLATE


FULLY WELDED TO SC1&SC2

SC1(U)
SC2(U)

STEEL COLUMN TO SLAB CONNECTION DETAIL OF SC1&SC2


SCALE 1 : 20

FOR TENDER
GOOD FOR CONSTRUCTION
REVISIONS & AMENDMENTS
REV. DESCRIPTION DATE SAFE AUSTRALIA PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE
A ISSUED FOR TENDER 26.04.2017 DESIGN & CONSULTING ENGINEERS 746 NEW SOUTH HEAD RD 160509 BT 26.04.2017 26.04.2017
CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT
SUITE 7, 8 MCFARLANE STREET
ROSE BAY NSW 2029 APPROVED BY CHECKED BY SHEET SIZE SCALE
MERRYLANDS, NSW 2160, Australia AN VR A-1 1:100
P: 02 8872 4902
M: 04 3734 2436 DRAWING CONTENT CLIENT DRAWING NO. REVISION
E: contact@safeoz.com.au
www.safeoz.com.au
AZHAR M. NASIR
MIEAust, CPEng, NPER, (2016938)
LEVEL 1 PLAN AND SECTIONS 746 OSH PTY LTD S602 A
LEGEND:
120MM AFS LOGICWALL

150MM AFS LOGICWALL

162MM AFS LOGICWALL


1 2 3 4
F G H 1 2 3 4 200MM AFS LOGICWALL

RL 11.230 RL 11.230 RL 11.230 WALL UNDER


TOP OF PARAPET TOP OF PARAPET TOP OF PARAPET

7.850 7.820 7.775 7.850


RL 7.900 RL 7.900 RL 7.900
LEVEL 2 LEVEL 2 LEVEL 2
NEIGHBOUR RETAINING
WALL
1
S301
4.770 4.800 4.800
RL 4.850 RL 4.850 RL 4.850
LEVEL 1 LEVEL 1 LEVEL 1

D
2 S302 2.750 2.750
S301
1.720 1.750 1.750 1.750
RL 1.800 RL 1.800 RL 1.800
GROUND FLOOR GROUND FLOOR 1.200 GROUND FLOOR

0.250
RL 0.250 RL 0.250 RL 0.250
PUMPOUT PIT PUMPOUT PIT PUMPOUT PIT

PERMEATION GROUTING PERMEATION GROUTING

SECTION C SECTION D SECTION E


SCALE 1 : 100 S602 SCALE 1 : 100 S602 SCALE 1 : 100 S602

1 2 3 4 1 2 3 4
1 2 3 4
11.250
RL 11.230 RL 11.230
TOP OF PARAPET TOP OF PARAPET
RL 11.230
TOP OF PARAPET

7.850 7.820 7.850


RL 7.900 RL 7.900
7.850 LEVEL 2 LEVEL 2
RL 7.900
LEVEL 2

4.800 4.800
RL 4.850 RL 4.850
4.800 LEVEL 1 4.030 LEVEL 1
RL 4.850 3.800
3.800
LEVEL 1
2.750 2.750 2.750

2.750 2.750
1.750 1.750 1.750
RL 1.800 RL 1.800
1.750 GROUND FLOOR 1.200 GROUND FLOOR
RL 1.800 0.690
1.200 GROUND FLOOR
RL 0.250 RL 0.250
PUMPOUT PIT PUMPOUT PIT
RL 0.250
PUMPOUT PIT PERMEATION GROUTING

PERMEATION GROUTING

SECTION F SECTION G
SECTION S602
SCALE 1 : 100 SCALE 1 : 100 S602
E1
SCALE 1 : 100 S602
FOR TENDER
GOOD FOR CONSTRUCTION
REVISIONS & AMENDMENTS
REV. DESCRIPTION DATE SAFE AUSTRALIA PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE
A ISSUED FOR TENDER 26.04.2017 DESIGN & CONSULTING ENGINEERS 746 NEW SOUTH HEAD RD 160509 BT 26.04.2017 26.04.2017
CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT
SUITE 7, 8 MCFARLANE STREET
ROSE BAY NSW 2029 APPROVED BY CHECKED BY SHEET SIZE SCALE
MERRYLANDS, NSW 2160, Australia AN VR A-1 1:100
P: 02 8872 4902
M: 04 3734 2436 DRAWING CONTENT CLIENT DRAWING NO. REVISION
E: contact@safeoz.com.au
www.safeoz.com.au
AZHAR M. NASIR
MIEAust, CPEng, NPER, (2016938)
SECTIONS & DETAILS - 02 746 OSH PTY LTD S702 A
LEGEND:
120MM AFS LOGICWALL

200
3
150MM AFS LOGICWALL

2 UP 162MM AFS LOGICWALL


S901

200
200MM AFS LOGICWALL
3

162

162
WALL UNDER
2 UP 1
S901 UP UP SLAB THICKNESS BY PTC
S901

1376
1

162
S901

162
150
4

162
100
4
F F

GROUND STAIR LEVEL 1 STAIR LEVEL 2 STAIR


SCALE 1 : 50 SCALE 1 : 50 SCALE 1 : 50

F
6.960
0
60

200
N12@150
E F
N12@300
7.850 RL 7.900

18
60 LEVEL 2

0
0
200

N12@300
0

N12@300
18

N12@300
N12@150
940
N12@300 N12@150

N12@150
6.960
60
0
200

4.800 RL 4.850
LEVEL 1

4.030
N12@150 0
60

200
STARTER BARS
1910

N12@150 STARTER BARS

N12@150
4.800 RL 4.850

18
LEVEL 1 N12@300

0
200

N12@300
N12@150
180

820

N12@300 N12@150 N12@300


STARTER BARS N12@150
4.030
150 150 600
200

N12@150
1.750 RL 1.800
N12@150 STARTER BARS
N12@300 GROUND FLOOR

SECTION 1 SECTION 2 250


SCALE 1 : 25 S901 SCALE 1 : 25 S901

FOR TENDER
GOOD FOR CONSTRUCTION
REVISIONS & AMENDMENTS
REV. DESCRIPTION DATE SAFE AUSTRALIA PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE
A ISSUED FOR TENDER 26.04.2017 DESIGN & CONSULTING ENGINEERS 746 NEW SOUTH HEAD RD 160509 BT 26.04.2017 26.04.2017
CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT
SUITE 7, 8 MCFARLANE STREET
ROSE BAY NSW 2029 APPROVED BY CHECKED BY SHEET SIZE SCALE
MERRYLANDS, NSW 2160, Australia AN VR A-1 1:100
P: 02 8872 4902
M: 04 3734 2436 DRAWING CONTENT CLIENT DRAWING NO. REVISION
E: contact@safeoz.com.au
www.safeoz.com.au
AZHAR M. NASIR
MIEAust, CPEng, NPER, (2016938)
STAIRS DETAILS 746 OSH PTY LTD S901 A