Pile cap ,PC1

Pile Capacity = 60 MT
dia 500 mm
L= 15000 mm
E= 25000 N/sq.mm
A= 196349.5 sq.mm
k= 5000 T/m

Pile location Pile cap thk (m) = 0.1 0.2 0.5 0.7
in pile cap STAAD Vertical Vertical Vertical Vertical
Node L/C Fy Mton Fy Mton Fy Mton Fy Mton
25 1 LOAD CASE 1 DL 221.01 359.76 395.299 397.495
31 1 LOAD CASE 1 DL 221.01 359.76 395.299 397.495
Central pile 61 1 LOAD CASE 1 DL 1115.959 560.96 418.802 410.021
91 1 LOAD CASE 1 DL 221.01 359.76 395.299 397.495
97 1 LOAD CASE 1 DL 221.01 359.76 395.299 397.495

1200

1000

800
REACTION

600

400

200

0
0.1 0.2 0.5 0.7 0.9 1.2 1.5 1.8 2 2.2 2.5
PILE CAP THK
0.9 1.2 1.5 1.8 2 2.2 2.5
Vertical Vertical Vertical Vertical Vertical Vertical Vertical
Fy Mton Fy Mton Fy Mton Fy Mton Fy Mton Fy Mton Fy Mton
398.327 398.884 399.159 399.322 399.399 399.46 399.53
398.327 398.884 399.159 399.322 399.399 399.46 399.53
406.693 404.464 403.365 402.711 402.404 402.161 401.878
398.327 398.884 399.159 399.322 399.399 399.46 399.53
398.327 398.884 399.159 399.322 399.399 399.46 399.53

Center Pile
Peripheral Pile

9 1.2 1.5 1.8 2 2.2 2.5


CAP THK