Electrical Inverter Test Protocol:

The Inverter is tested for the following:

1. Electrical ratings
2. Inversion
3. Leakages
4. Pressure.

Test Procedure For Electrical Inverter:

1. Connect hydraulically and electrically the invertor to the work bench; take care that the
voltage is in line to the drawing.

2. Starts the pump and act the commands to test the inversions. Verify that the oil comes out
alternatively from first and second outlet and that the pin exits otherwise reject it.

3. Plugs the two outlets and pressurize up to 300 bar end test 3 cycles .
4. Verify that there are no leakages .

5. Depressurize the work banch, disconnecting it electrically and hydraulically and and plugs
the oulets and paste the label.

6. Checks the electrical pressure during the inversion cycles.

7. Whole test has been done with 100cst oil.