You are on page 1of 4

DESIGN OF LIFT IRRIGATION PUMP

AMOUNT OF WATER REQUIRED FOR IRRIGATION

CALCULATION FOR AREA

A =

FLOW VELOCITY

V =

LENGTH OF PIPE

L =

FRICTIONAL FACTOR

f =

FRICTIONAL HEAD

Hf =

ELEVATION HEAD

He =

SUCTION HEAD

Hs =
OUT LET HEAD LOSS

Ho =

TOTAL HEAD

H =

POWER OF PUMP

H =
Area of Land (kanal) 500
Area of Land (acre) 61.9601
Duty of Water (acre/cusec) 121
Water Required (cusec) 0.512067
Percent Water available from other source (%) 10
Amount of water to be lift by Pump (cusec) 0.46086
No of Hours Pump will Operate (hours) 8
Design Discharge (cusec) 1.382581
Design Discharge (cumec) 0.03918

Dia of Pipe (inch) 4


Dia of Pipe (meter) 0.1016
Crossectional Area of Pipe (Sq meter) 0.008107

Velocity 4.832724

Length of Pipe (feet) 150


Length of Pipe (meter) 45.72

Frictional Factor 0.009101

Frictional Head Loss 19.520548

Elevational Head (feet) 20


Elevational Head (meter) 6.0959998

Suctional Head (feet) 15


Suctional Head (meter) 4.5719999
Out let Head Loss (meter) 1.190378

Total Head (meter) 31.37893

Efficiency of Pump (%) 65

Power of Pump (Hp) 25.21926