You are on page 1of 3

Re: Verification Manuals [!!! NOT REAL SENDER - Open with care !!!

SPF
softfail] [!!! NOT REAL SENDER - Open with care !!! SPF softfail]
Xiang Hou Cheong to: HanChuin Teo 12/10/2013 03:26 PM

Hi Teo,

Alright. Kindly find the following for the reply from Pravin, ANSYS India:

To get the velocity fluctuation if you assume the isotropic turbulence then you can get the information
on velocity fluctuation using turbulence kinetic energy as
u_prime = v_prime = w_prime = (3k/2)^(1/2)
However, if you have un=isotropic turbulence, then you would need to either use RSM model or LES
to get the information on each component of velocity fluctuations.
I hope this answers your question.
Should you required further information/clarification, please do not hesitate to contact
me.

Thanks and regards,

Cheong Xiang Hou


Technical Sales Engineer
CAD-IT Consultants (M) Sdn Bhd
DID: (603) 7806-4626
Mobile: (6016) 608 3381

www.cadit.com.sg

Bringing you tomorrow’s technology today!

Confidentiality Notice

This page and any accompanying documents are intended only for the use by the individual
or entity to which it is addressed and solely for its intended purpose. It may contain
information that is privileged, confidential and exempt from disclosure under the applicable
law. You are hereby notified that any unauthorized use, dissemination, distribution or
copying, or the taking of any action based on the contents of such information is strictly
prohibited. If you are not the intended recipient and have received this communication in
error, please notify us immediately and delete all attachments immediately from your system.
Thank you.

On Tue, Dec 10, 2013 at 3:25 PM, HanChuin Teo <hcteo@technip.com> wrote:
Hi Cheong,
I do not require the validation for version 14.5. I will do that upon the release of
version 15. I will send the form over to you when the time comes.

In the meantime, could you provide me with the confirmation on the usage of
turbulent kinetic energy in plotting the Urms contour? Appreciate it.

Regards,

Han Chuin TEO


Graduate Technical Safety Engineer, Technical Safety Department
_______________________________________________________________ __________
nd
Technip Malaysia - 2 Floor Wisma Technip - 241 Jalan Tun Razak - 50400 Kuala Lumpur - Malaysia -
www.technip.com
Tel (Direct): +603 2146 4494 – Switchboard: +603 2116 7888 – Fax: + 603 2116 7999
Please consider the environment before printing this email or its attachments.

From: Xiang Hou Cheong <xianghou.cheong@cadit.com.sg>


To: HanChuin Teo <hcteo@technip.com>,
Date: 12/04/2013 05:23 PM
Subject: Verification Manuals [!!! NOT REAL SENDER - Open with care !!! SPF softfail]

Hi Teo,

You can search for "Verification Manuals" in the ANSYS Help. It will show you all the
verification done by ANSYS including CFD and FEA.

Should you required further information/clarification, please do not hesitate to


contact me.

Thanks and regards,

Cheong Xiang Hou


Technical Sales Engineer
CAD-IT Consultants (M) Sdn Bhd
DID: (603) 7806-4626
Mobile: (6016) 608 3381

www.cadit.com.sg

Bringing you tomorrow’s technology today!

Confidentiality Notice

This page and any accompanying documents are intended only for the use by the individual
or entity to which it is addressed and solely for its intended purpose. It may contain
information that is privileged, confidential and exempt from disclosure under the applicable
law. You are hereby notified that any unauthorized use, dissemination, distribution or
copying, or the taking of any action based on the contents of such information is strictly
prohibited. If you are not the intended recipient and have received this communication in
error, please notify us immediately and delete all attachments immediately from your
system. Thank you.

This email and any attached files ("Message") may contain


confidential and/or privileged information. It is intended
solely for the addressee(s). If you receive this Message in
error, inform the sender by reply email, delete the Message
and destroy any printed copy.
Any unauthorized use, distribution, or copying of this
Message or any part thereof is prohibited. Emails are
susceptible to alteration. Neither Technip nor any of its
affiliates shall be liable for the Message if altered or
falsified nor shall they be liable for any damage caused by
any virus that might be transmitted with this Message.