AIRCRAFT MAINTENANCE MANUAL

**ON A/C ALL


TASK 05−20−00−210−802
General Visual Inspection of the Left and Right Elevator LVDT Connectors (MRB# 052000−304)
1. General
A. The maintenance procedure that follows is for the general visual inspection of the left and right
elevator LVDT (Linear Variable Differential Transformer) connectors. This procedure is for the
Lightning/High Intensity Radiated Fields protection on the left and right elevator LVDT
connectors. The LVDTs are located in the horizontal stabilizer.

2. Job Set−Up Information


Subtask 05−20−00−946−014

A. Reference Information

REFERENCE DESIGNATION
TASK 24−00−00−910−801 Electrical/Electronic Safety Precautions

TASK 24−00−00−910−802 Electrostatic Discharge Safety Precautions

WM20−15−10−401 Wiring Diagram Manual

3. Job Set−Up
Subtask 05−20−00−910−023

A. Obey all the electrical/electronic safety precautions (Refer to TASK 24−00−00−910−801).

Subtask 05−20−00−910−024

B. Obey all the electrostatic discharge safety precautions (Refer to TASK 12−00−06−861−802).

Subtask 05−20−00−010−001

C. For the left hand side, open the access panel that follows:

REFERENCE DESIGNATION
332BB Access Panel

Subtask 05−20−00−010−004

D. For the right hand side, open the access panel that follows:

PSM 1−84−2 − MASTER


EFFECTIVITY:
Page 604
See first effectivity on page 604 of 05−20−00 05−20−00 Mar 05/2017
E
AIRCRAFT MAINTENANCE MANUAL

REFERENCE DESIGNATION
342BB Access Panel

4. Procedure
Refer to Figure 602.
Subtask 05−20−00−210−002

A. Do a general visual inspection of the Lightning/High Intensity Radiated Fields protection on the
left and right LVDT (1) electrical connectors (2) as follows:
(1) Look at the connectors on the LVDTs (1).
(2) Make sure that all connectors and backshells are correctly installed.
(3) Make sure that all connectors are in a good condition and are not damaged.
(4) Make sure that no red witness bands (indicators) on the connectors are visible.
NOTE: If the red witness band is visible, the backshell is unlocked. Refer to the Wiring
Diagram Manual, PSM 1−84−2W, 20−15−10−401, as necessary for information
about the applicable maintenance corrective−action.
(5) Make sure that the ground wire on each transformer body is not worn or damaged.
(6) Make sure that each ground stud (3) is correctly installed.

5. Close Out
Subtask 05−20−00−941−013

A. Remove all tools, equipment and unwanted materials from the work area.

Subtask 05−20−00−410−001

B. For the left hand side, close the access panel that follows:

REFERENCE DESIGNATION
332BB Access Panel

Subtask 05−20−00−410−002

C. For the right hand side, open the access panel that follows:

REFERENCE DESIGNATION
342BB Access Panel

PSM 1−84−2 − MASTER


EFFECTIVITY:
Page 605
See first effectivity on page 604 of 05−20−00 05−20−00 Mar 05/2017
E
AIRCRAFT MAINTENANCE MANUAL

LEGEND
1. LVDT.
2. Electrical Connector.
3. Ground stud.

2
brah42a01.dg, gg, 11/02/02

Left and Right Elevator LVDT Connectors − Inspection/Check


Figure 602

PSM 1−84−2 − MASTER


EFFECTIVITY:
Page 606
See first effectivity on page 604 of 05−20−00
05−20−00 Mar 05/2017