A. Reference Information
REFERENCE DESIGNATION
TASK 24−00−00−910−801 Electrical/Electronic Safety Precautions
3. Job Set−Up
Subtask 05−20−00−910−023
Subtask 05−20−00−910−024
B. Obey all the electrostatic discharge safety precautions (Refer to TASK 12−00−06−861−802).
Subtask 05−20−00−010−001
C. For the left hand side, open the access panel that follows:
REFERENCE DESIGNATION
332BB Access Panel
Subtask 05−20−00−010−004
D. For the right hand side, open the access panel that follows:
REFERENCE DESIGNATION
342BB Access Panel
4. Procedure
Refer to Figure 602.
Subtask 05−20−00−210−002
A. Do a general visual inspection of the Lightning/High Intensity Radiated Fields protection on the
left and right LVDT (1) electrical connectors (2) as follows:
(1) Look at the connectors on the LVDTs (1).
(2) Make sure that all connectors and backshells are correctly installed.
(3) Make sure that all connectors are in a good condition and are not damaged.
(4) Make sure that no red witness bands (indicators) on the connectors are visible.
NOTE: If the red witness band is visible, the backshell is unlocked. Refer to the Wiring
Diagram Manual, PSM 1−84−2W, 20−15−10−401, as necessary for information
about the applicable maintenance corrective−action.
(5) Make sure that the ground wire on each transformer body is not worn or damaged.
(6) Make sure that each ground stud (3) is correctly installed.
5. Close Out
Subtask 05−20−00−941−013
A. Remove all tools, equipment and unwanted materials from the work area.
Subtask 05−20−00−410−001
B. For the left hand side, close the access panel that follows:
REFERENCE DESIGNATION
332BB Access Panel
Subtask 05−20−00−410−002
C. For the right hand side, open the access panel that follows:
REFERENCE DESIGNATION
342BB Access Panel
LEGEND
1. LVDT.
2. Electrical Connector.
3. Ground stud.
2
brah42a01.dg, gg, 11/02/02