You are on page 1of 22

No.

of Manufacturi Country Unit Price Total Amt


Sr. Instruments/Machine Column Model instrum ng company of origin In USD Remark
No Name 1 IN USD
ent

Temper
ture
Parame
ter
UV-A Calibrat
lamps at on
340nm only ,3
Accelerated weathering & UV-B Quv/se
1 1 Q-Lab, USA USA 70 70 Temp
Tester lamps at cal.
310 nm, points ,
Temp:3 By using
2-60C single
sensor
method
.

3
point,
Cometech upto 1
Adhesive Holding power Time
2 tester QC -801 1 Testng Taiwan 70 70 hr
machine tmer
calibra
ton
Pressur
e gauge
calibrat
on , 5
Pressure Cal.
: 4.1 Point 3
Netherla
3 Autoclave Bar, 3850 El 1 Tuttnauer 100 100 Temp
nd,
Temp: cal.
135C points ,
By using
single
sensor
method

3 Temp
cal.
O Sung points ,
Temp:3 OS4-
4 Baking Oven Tester 1 Scientfic Co. Korea 50 50 By using
00C 265TO Ltd., Korea single
sensor
method

Hepa Facility
filter JSCB- Not
5 Bio safety Cabinet Leak 1 JSR korea 0 0
check, 1200SB Avaliabl
air flow e

3 points
Volume: 50mL German
6 Burrete 5 Duran 60 300 calibrat
50mL y on
Conduc
tvity0.0
μS/cm
(ppm) -
20.00
mS/cm
(ppt),
Temp: 0
- 100.0
°C / 32 -
212 °F,
TDS
Range(C Facility
oefficien CON30 CLEAN Not
7 CLEAN CON30 Tester 1 Instruments China 0 0
t:0.5) Avaliabl
0.0 e
mg/L
(ppm) -
20.00
g/L
(ppt),
Salinity
Range
0.0
mg/L
(ppm) -
13.00
g/L
(ppt)
with 9
temp
sensors
method
,
mappin
g will be
done
for 3
temp
calibrat
RH:20- on
98%,Te point,
8 Climate Chamber mp: 1 Taiwan 500 500 test for
-40C to period
+100C of 6 hrs.
Checke
d for
error,
stability
and
uniform
ity.
Humidit
y 30 to
90%Rh
@25ᵒC
with 9
temp
sensors
method
,
mappin
g will be
done
for 3
temp
calibrat
RH:30- on
CM
98%,Te Nano-80- point,
Envirosystem India
9 Climate Chamber mp: 1 500 500 test for
-30C to A-H s Pvt. Ltd, period
+85C India of 6 hrs.
Checke
d for
error,
stability
and
uniform
ity.
Humidit
y 30 to
90%Rh
@25ᵒC

Range
-320
g,Reada
bility
-0.1 mg,
10
points
calibrat
0.1g to AUW320
10 Electric balance 1 Shimazu Japan 100 100 on,
320 gm checked
for
error,
repeata
bility
and
eccentri
city
Temp:
200C,
stroke:
100mm,
Speed: Facility
0.01- Biolin Not
11 Force tensiometer 500mm Sigma 700 1 Syden 0 0
scientfic Avaliabl
/min, e
Angle:
0-180,
Load:
5gm

3 temp
points
by
Temp: single
12 Fridge -18 to 1 110 110 Sensor
18 C calibrat
on
method

3 temp
points
by
Temp: single
13 Furnace JSMF-45T 1 JSR Korea 110 110
1000C Sensor
calibrat
on
method

Volume:
28.95c Facility
Quantachro German
m3, 1200e, Not
14 Gas pycnometer 1 me, 0 0
56.55 UPY-31-F y Avaliabl
Germany.
cm3, e
7cm3

force,
hardness tester 0 weight

Weight:
2 kg, Facility
15 Impact Testng Machine Pendulu IT504 1 Tenious UK 0 0 Not
m Olsen, UK Avaliabl
allingme e
nt
3 temp
points
by
Temp: single
16 Incubator SMI6 1 Shellab USA 110 110
120C Sensor
calibrat
on
method

3 temp
points
by
Temp: single
17 Incubator 1 JSR Korea 110 110
120C Sensor
calibrat
on
method

Angle
Cometech Measur
Angle: QC -805(A) 1
18 Inital Adhesion tester Testng Taiwan 30 30 ement,
20°~40° machine 3 Cal.
Point

Heatng
rate: 7-
20
C/min,
Stability
: Temp: 756/831 Facility
200C, KF Switzerla Not
19 KF Coulometer Cooling Coulomete 1 Metrohm 0 0
nd Avaliabl
rate:4- r e
11C/min
,
Measur
ement:
100mL/
min
3 temp
points
by
Temp: Tenious single
20 Melt Flow Indexer MP200 1 USA 50 50
450C Olsen, UK Sensor
calibrat
on
method

20-
200uL, 20-200uL, 3 points
21 Micro pipette 100- 2 Dragon Lab China 60 120 calibrat
100- 1000uL on
1000uL

Lens: Facility
40X, Not
22 Microscope 100X 1 Micros Austria 0 0 Avaliabl
and e
110X

temper
ature of
water
bath,
negatv
e
oil content analyzer 0 temper
ature of
fridge
unit,
flow of
rotamet
er, tme
Load Load
cell: 100 cell:
N, 100 N,
Speed: Speed:
Cometech
3- 3-
23 Peel testng machine 600mm QC-507M1 1 Testng Taiwan 200 200 600mm
machine
/ min, / min,
Displace Displac
ment: ement:
300 mm 300 mm

Calibrat
on by
pH: 4, 7 pH 211 Hanna, mV
24 pH Meter 1 India 60 60
10 Vietnam simulat
on
method

3 points
5ml to 5 mLto 25 10 German
25 Pipette Duran 60 600 calibrat
25 mL mL y on

Facility
Current:
26 Potentometric Titrator 800mV, 848 Titrino 1 Metrohm, Switzerla Not
0 0
plus Swiss nd Avaliabl
400mA e

TEMP,
humidit
reacton chamber 0 y,
pressur
e

(Class-
5 mg to F1,F2,M
500gm ( 5 mg to 1,M2)
27 Standard weight 50 Nos. 500gm 1 - China 250 250 All
Weights weights
) calibrat
on

Facility
0- Not
28 Tesla Meter 3000.0 TM-801 1 Kantec Japan 0 0 Avaliabl
mT e
Thermal
conduc Facility
29 Thermal Conductvity tvity λ fox 320 Laser Comp, USA Not
1 0 0
measuring device value at USA. Avaliabl
different e
temp

Calibrat
Load on in
cell: tension
10KN, Mode
Speed:
30 Universal Testng Teniuos for 10
50mm/ H10KS 1 UK 250 250
Machine (UTM) Olsen, UK Kn load
min, cell , 10
Displace Calibrat
ment: on
43 inch point

ultrasonic hand held thickne


0
thickness gauze ss

RPM
Measur
emnet
Elektron upto
31 Viscometer RPM Sheen-480 1 Technology, UK 25 25 3000
UK rpm , 5
Calibrat
on
point
RPM
Measur
emnet
upto
3000
rpm , 5
Calibrat
Shanghai on
Temp:2 Kingdak point ,
50C
32 Viscometer ,RPM: DV-1H 1 Scientfic China 100 100 Temp
Instrument measur
100 Co, Ltd. ement
3
calibrat
on
point by
using
single
sensor

RPM
Measur
emnet
upto
3000
rpm , 5
Calibrat
on
Temp:1 point ,
00C Grace
33 Viscosity meter ,RPM: M3600 1 Instrument USA 100 100 Temp
measur
600 ement
3
calibrat
on
point by
using
single
sensor

Sub Total 3915


Discount 392
@10%
Grand 3524
Total
electro
ISO/IEC :17025 Calibraton OTS-unit OTS- total meter-unit
accredited/Non Perform at price in price price in
accredited site / in house taka usd

ISO/IEC :17025
accredited - At-site 22000 22000 regret
(NABL India)

ISO/IEC :17025
accredited - At-site 8000 8000 75
(NABL India)
ISO/IEC :17025
accredited - At-site 14000 14000 50
(NABL India)

ISO/IEC :17025
accredited - At-site 8000 8000 60
(NABL India)

NA NA 60000 60000 60

ISO/IEC :17025
accredited - In- house 2500 12500
(NABL India)
NA NA 16000 16000
ISO/IEC :17025
accredited - At-site 14000 14000 75
(NABL India)
ISO/IEC :17025
accredited - At-site 14000 14000
(NABL India)

ISO/IEC :17025
accredited - At-site 6000 6000
(NABL India)
NA NA 18000 18000 100

ISO/IEC :17025
accredited - At-site 14000 14000
(NABL India)

ISO/IEC :17025
accredited - At-site 14000 14000
(NABL India)

NA NA 5000 5000 75

120

NA NA 18000 18000 100


ISO/IEC :17025
accredited - At-site 10,000 10,000 60
(NABL India)

ISO/IEC :17025
accredited - At-site 10,000 10,000 60
(NABL India)

ISO/IEC :17025
accredited -( Non At-site 8000 8000 regret
NABL India)

NA NA 12000 12000 75
ISO/IEC :17025
accredited - At-site 12000 12000 100
(NABL India)

ISO/IEC :17025
accredited - In- house
(NABL India)

NA NA 30000 30000 70

120
ISO/IEC :17025
accredited -( Non At-site 18000 18000
NABL India)

ISO/IEC :17025
accredited -( Non At-site 5000 5000 45
NABL India)

ISO/IEC :17025
accredited - In- house 2500 25000
(NABL India)

NA NA 16000 16000 60

80

ISO/IEC :17025
accredited - In- house 1000 50000
(NABL India)

NA NA 16000 16000
NA NA 18000 18000 regret

ISO/IEC :17025
accredited -
(NABL India) Non At-site 18000 18000 400
Nabl foe spped &
Displacement

60

ISO/IEC :17025
accredited - At-site 12000 12000 90
(NABL India)
ISO/IEC :17025
accredited - At-site 12000 12000 90
(NABL India)

ISO/IEC :17025
accredited - At-site 12000 12000 90
(NABL India)

527500 2115

vat 15% 79125

Total 606625