You are on page 1of 10

LATERAL SUPPORT

SLIDE SHOW

Modified for use in CE470, Purdue University, April 2004


Fully unsupported beams. The unbraced length is equal to the entire
length of the member.
These beams are continually supported with the deck that is
mechanically attached with screws or welds.
During construction, these
girders are fully
unsupported. The unbraced
length is the full length of
the girder.

Once the joists are placed


in position and attached,
the unbraced length is
reduced to the joist
spacing.
Bracing is not only accomplished by joists. Here, beams
are used as blocking and spaced to provide the necessary
lateral support.
Similarly, for the Chemical Engineering Building addition
(Purdue), the beams have no lateral support during placement
of the metal deck. The girders, meanwhile, have an unbraced
length corresponding to the spacing of the beams.
Another image of placement of metal deck for the Chemical
Engineering addition.
The deck is attached to the beams with puddle welds. Shear
studs are also welded in place so that the floor slab and beam
will act as a composite section in flexure.
These beams are now fully laterally supported.
Lateral bracing must be used for any member loaded in
bending, including those that are curved or inclined.

You might also like