Development Length - Tension

Units
f'c = 28 Mpa
fy = 420 Mpa
fyt = 420 Mpa
As provided = 510.00 * mm 2 d
h
As req'd = 510.00 * mm 2 As
Area estr Atr = 142 * mm 2
db = 25.4 mm
No. Barras n= 0 *
Sep estr s= 0 * mm
yt = b
Sup 1.00
Epox ye = 1.00 * cells with * indicate that this information is optional
Diám ys = 1.00 Atr, n and s are needed only if the Ktr term is used

Conc l= 1.00 As reqd is needed only if the As reqd/As prov reduction is used
Rec cb = 50.00 mm All terms with * can be omitted and a conservative
y ty e = 1.00
Ktr = 0.000
Confinam (cb + Ktr)/db = 1.969

Barras mayores a No. 7

fy y ty ey s
ld = db = 46.69 diameters
1185.92 mm. (not adjusted for A
1.7 l f c'

f y y ty ey s 72.16 diameters
1832.78 mm. (not adjusted for A
ld = db =
1.1 l f c
'

Barras Menores a No. 6

f y yty ey s diameters
mm. (not adjusted for A
ld = db =
2.1 l fc'

f y y ty ey s diameters
ld = db = mm. (not adjusted for A
1.4 l f c'

Ecuación general
9 fy y ty ey s 36.29 diameters
ld = db = 921.74 mm. (not adjusted for A
10 l f c'  c b  K tr 
 
 db 
As req'd/As provided = 1.00 ld = 921.74 mm. (adjusted for As req'd/As provided)

40 db 1016.00 but not less than


Diámetro mm Area mm2 No. pulg
6.40 32 2 1/4
9.50 71 3 3/8
12.70 129 4 1/2
15.90 199 5 5/8
19.10 284 6 3/4
22.20 387 7 7/8
Barra No. 8 25.40 510 8 1
28.70 645 9 1 1/8
32.30 819 10 1 1/4
35.80 1006 11 1 3/8
rmation is optional 43.00 1452 14 1 3/4
Ktr term is used 57.30 2581 18 2 1/8

s prov
reduction is used
d a conservative ld will result

# db
4 db 5 db 6 db D (mm)
mm
#3 a #8 101.60 155.00
#9, #10 y #11 0.00
#14 y #18 0.00

adjusted for As req'd/As provided)

adjusted for As req'd/As provided) Traslapos


fy Mpa

adjusted for As req'd/As provided)


C.12.2.4 — Los factores a usar en las expresiones para la longitud de desarrollo de barra
(a) Cuando para el refuerzo horizontal se colocan más 300 mm de concreto fresco debajo
(b) Barras o alambres con recubrimiento epóxico con menos de b 3d de recubrimiento, o
No obstante, el producto te ψψ no necesita ser mayor de 1.7.
(c) Para barras No. 6 (3/4”) ó 20M (20 mm) o menores y alambres corrugados, s 0.8 ψ= .
(d) Donde se use concreto liviano, λ no debe exceder de 0.75 a menos que se especifiqu
adjusted for As req'd/As provided)
adjusted for As req'd/As provided) 0.9

sted for As req'd/As provided)

300 mm
Diametro doblamiento
No. Octavos Pulg D (mm)
3 3/8 60
4 1/2 80
5 5/8 95
6 3/4 115
7 7/8 135
8 1 155
9 1 1/8 240
10 1 1/4 275
11 1 3/8 305
14 1 3/4 465
18 2 1/8 610

GANCHO A fy
90 180 <= >=
12 db 420 Mpa 750 Mpa
Traslapo (mm) 40 db
459.80 358.20 757.428 1866.9 1016.00

ara la longitud de desarrollo de barras y alambres corrugados en tracción en C.12.2 son los siguientes:
s 300 mm de concreto fresco debajo de la longitud de desarrollo o un empalme, t 1.3 ψ= . Otras situaciones t 1.0 ψ= .
menos de b 3d de recubrimiento, o separación libre menor de b 6d , e 1.5 ψ= . Para todas las otras barras o alambres con recubrimiento e

s y alambres corrugados, s 0.8 ψ= . Para barras No. 7 (7/8”) ó 22M (22 mm) y mayores, s 1.0 ψ= .
de 0.75 a menos que se especifique ct f (véase C.8.6.1). Donde se use concreto de peso normal, 1.0 λ= .
s t 1.0 ψ= .
o alambres con recubrimiento epóxico, e 1.2 ψ= . Refuerzo sin recubrimiento y refuerzo recubierto con cinc (galvanizado), e 1.0 ψ= .
anizado), e 1.0 ψ= .
Development Length - Compression

Units
f'c = 21 Mpa
fy = 420 Mpa As
As = 284.00 mm2
db = 12.7 mm

l= 1.00
As req'd = 284.00 mm2 b

0 . 24 f y 279.35
l dc = d b =
l f c
'

 0 . 043 f y d b = 229.36

0 . 043 mm 2
N
As req'd =

As req'd/As provided = 1.00


Enclosed with spirals or ties (ACI 12.3.3) = 1.00

ldc = 279.35

Condiciones de anclaje para ganchos estandar

DMI - DMO
BARRA db (mm) Ldh (mm) hmin col (mm) hmin viga (mm)
3 9.50 208.97 258.47 201.5
4 12.70 279.35 328.85 252.7
5 15.90 349.74 399.24 303.9
6 19.10 420.13 469.63 355.1
7 22.20 488.32 537.82 404.7
8 25.40 558.71 608.21 455.9
9 28.70 631.30 680.80 508.7
10 32.30 710.48 759.98 566.3
11 35.80 787.47 836.97 622.3
14 43.00 945.84 995.34 737.5
18 57.30 1260.39 1309.89 966.3

rec 4 cm y diámetro estribo 0.95 cm (3/8" Barra No. 3)


Longitudes de desarrollo para barras rectas a tracción

DMI - DMO DES


BARRA No. Db (mm) Ld (mm) Ld (mm)
Otras Altas 1.30 Otras
3 9.50 414.61 539.00 403.10
4 12.70 554.27 720.56 538.88
5 15.90 693.93 902.11 674.66
6 19.10 833.59 1083.67 810.44
7 22.20 1196.86 1555.92 941.97
8 25.40 1369.38 1780.20 1077.75
9 28.70 1547.29 2011.48 1217.78
10 32.30 1741.38 2263.79 1370.53
11 35.80 1930.07 2509.09
14 43.00 2318.24 3013.72
18 57.30 3089.20 4015.95

hv=20*db col
hc=20*db vig
d
h

Barra No. 4

mm

>300 mm

mm

mm but not less than 200 mm

DES
Ldh (mm)2 hmin col (mm)3 hmin viga (mm)4
161.24 250.74 201.5
215.55 305.05 252.7
269.86 359.36 303.9
324.17 413.67 355.1
376.79 466.29 404.7
431.10 520.60 455.9
487.11 576.61 508.7
548.21 637.71 566.3
607.62 697.12 622.3
729.82 819.32 737.5
972.52 1062.02 966.3
DES
Ld (mm)
Altas 1.30
524.03
700.54
877.05
1053.57
1224.57
1401.08
1583.11
1781.69
Diámetro mm Area mm2 No. No. Diametro doblamiento
6.40 32 2 1/4 No. OctavoPulg D (mm)

9.50 71 3 3/8 3 3/8 60


12.70 129 4 1/2 4 1/2 80
15.90 199 5 5/8 5 5/8 95
19.10 284 6 3/4 6 3/4 115
22.20 387 7 7/8 7 7/8 135
25.40 510 8 1 8 1 155
28.70 645 9 1 1/8 9 1 1/8 240
32.30 819 10 1 1/4 10 1 1/4 275
35.80 1006 11 1 3/8 11 1 3/8 305
43.00 1452 14 1 3/4 14 1 3/4 465
57.30 2581 18 2 1/8 18 2 1/8 610

GANCHO A
# db 90 180
4 db 5 db 6 db 12 db 40 db
#3 a #8 50.80 232.40 181.60 508.00
#9, #10 y #11 50.80 63.50 232.40 194.30 508.00
#14 y #18 50.80 76.20 232.40 207.00 508.00

No aplica gancho para desarrollo de compresión


Development Length - Hooks

Units
f'c = 28 Mpa d
h
fy = 420 Mpa As
As = 129.00 mm2
db = 12.7 mm
l= 1.00
ye = 1.00 b
As req'd = 129.00 mm2

19.0 diameters
0 . 24y e f y
l dh = db = 241.93 mm
l f c'
150.0 mm
 150 mm .
8d b 101.6 mm

Multipliers
(a) Cover multiplier = 1 Rec mayor de 60 mm aplica 0.7
(b) tie or stirrup multiplier 1 Cuando se requiere 1-2db y resto-3
(c) ties 1 Si rec es menor de 60 mm no aplica
(d) As req'd/As provided 1.000 Rec mayor de 60 mm se puede red

ldc = 241.9 mm but not less than


and not less than
Diámetro mm Area mm2 No. No. Diametro doblamiento
6.40 32 2 1/4 No. Octavo
9.50 71 3 3/8 3
12.70 129 4 1/2 4
Barra No. 4 15.90 199 5 5/8 5
19.10 284 6 3/4 6
22.20 387 7 7/8 7
25.40 510 8 1 8
28.70 645 9 1 1/8 9
32.30 819 10 1 1/4 10
35.80 1006 11 1 3/8 11
43.00 1452 14 1 3/4 14
57.30 2581 18 2 1/8 18

Ganchos (mm)

mayor de 60 mm aplica 0.7 GANCHO A


ndo se requiere 1-2db y resto-3db en ldh # db 90 180
c es menor de 60 mm no aplica 0.8 4 db 5 db 6 db 12 db
mayor de 60 mm se puede reducir #3 a #8 50.80 232.40 181.60
#9, #10 y #11 63.50 232.40 143.50
but not less than 150.00 mm #14 y #18 76.20 232.40 156.20
and not less than 101.60 mm
Diametro doblamiento
Pulg D (mm)
3/8 60
1/2 80
5/8 95
3/4 115
7/8 135
1 155
1 1/8 240
1 1/4 275
1 3/8 305
1 3/4 465
2 1/8 610
Development Length - Headed Bars

Units
f'c = 4000 psi d
h
fy = 60000 psi As
As = 2.35 in 2
db = 1.00 in.
ye = 1.00
As req'd = 2.20 in. b
0 . 016 y e f y 15.2 diameters
l dt = db = 15.2 in.
'
f c

 6 in. 6 in.

8d b 8 in.

Multipliers
As req'd/As provided 0.936

ldc = 14.2 in. but not less than 6 in.


and not less than 8 in.
Development Length - Tension
Units
f'c = 4000 psi
fy = 60000 psi
fyt = 60000 psi
b= 14 * in. d
h
d= 30 * in.
As
h= 33 * in.
As = 3.79 * in 2
Atr = 0 * in 2
db = 1.27 in.
b
n= 3 *
s= 8 * in.
yt = 1.00
ye = 1.00 * cells with * indicate that this information is
ys = 1.00 optional. Mu, b, d, h and As are needed only to calculate

l= 1.00 As reqd. Atr, n and s are needed only if the Ktr term is
cb = 2.00 in. to be used. All terms with * can be omitted and
Mu = 430.90 * ft-k a conservative value of ld will result.
y ty e = 1
Ktr = 0.000
(cb + Ktr)/db = 1.575

3 fy y ty ey s
ld = db = 542.17 diameters
40 l f c'  c b  K tr 
688.56 in. (not adjusted for As req'd
 d 
 b 
As req'd = 3.44053 in 2 -
As req'd/As provided = 0.9077927 ld = 625.07 in. (adjusted for As req'd/As provided

but not less than 12 in.


d
h
As

b
nformation is
needed only to calculate

nly if the Ktr term is


be omitted and

ed for As req'd/As provided)

or As req'd/As provided)