You are on page 1of 2

HI-BOND

COMPOSITE FLOOR

HB938
Z275 GALVANIZED

LIMIT STATES
DESIGN
METRIC
DEPTH FROM MAXIMUM FACTORED PHYSICAL
Note SECTION MODULUS Moment of Inertia
NEUTRAL REACTIONS
1. Load Tables are NOMINAL MASS WITH
MIDSPAN SUPPORT MIDSPAN FULL
AXIS TO PROPERTIES
CORE AREA OF ZF75 BOTTOM OF EXTERIOR INTERIOR STEEL PROPERTIES
based on the design Sm Ss Im If
THICKNESS STEEL GALVANIZED DECK Y b (kN) (kN)
of ONE-WAY (mm3 x 103) (mm3 x 103) (mm4 x 103) (mm4 x 103)
(mm) (mm2) (kg/m2) (mm)
composite slabs
carrying uniformly 0.76 996.8 8.08 9.59 9.76 213.9 228.3 22.16 10.9 15.7 (PER METRE WIDTH)
distubuted loads on a 0.91 1197.4 9.65 11.70 12.31 266.8 274.0 22.26 15.3 22.3 In accordance
simple span basis. with CSA
1.22 1593.0 12.83 15.87 16.21 364.0 364.0 22.45 25.8 38.4
For complete design Specification
criteria see the 1.52 1992.1 15.96 20.00 20.06 454.4 454.4 22.65 38.9 58.7
S136-07
VICWEST Hi-Bond
Composite Floor SLAB THICKNESS 101 111 126 136 PHYSICAL
Designer's Manual. h(mm)
Slab Weight, W1(kN/m2) 1.89 2.11 2.45 2.68 PROPERTIES
2. A uniform loading in
Concrete Volume, (m3/m2) 0.078 0.088 0.103 0.113 COMPOSITE SLAB
excess of 10 kPa Base Steel Nominal (PER METRE WIDTH)
(200 psf) is often an Thickness IC d IC d IC d IC d
indication of Composite
(mm)
concentrated or Moment of
moving loads. Such 0.76 5455 78.8 7228 88.8 10548 103.8 13244 113.8 Inertia,
conditions may 0.91 5836 78.7 7725 88.7 11252 103.7 14109 113.7 I C (mm4 x 103)
require additional
1.22 6516 78.6 8613 88.6 12519 103.6 15673 113.6 Effective Depth,
reinforcing steel.
Contact VICWEST d (mm)
1.52 7121 78.4 9408 88.4 13662 103.4 17090 113.4
for additional design
Base Steel
information
Nominal 1 2 3 1 2 3 1 2 3 1 2 3
LOAD TABLE
3. Slab Thickness h, is Thickness Span Span Span Span Span Span Span Span Span Span Span Span Span
from underside of (mm) (mm)
steel deck to top of 1200 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 Maximum
concrete. Maximum 1400 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 Specified
0.76
span is not to exceed 1600 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 Uniformly
32h. 1800 16.4 16.4 18.5 18.5 Distributed Load
4. Properties and loads 1200 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
are based on Grade in kN/m 2 (kPa)
1400 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
230 steel (Grade 33 1600 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
steel) with a 0.91
1800 18.3 18.3 18.3 20.0 20.0 20.0 20.0 20.0 20.0 20.0 Shear Bond
minimum yield stress 2000 15.1 15.1 17.0 17.0 19.9 Coefficents
of 230 MPa (33,000
2200 k 1 = 29.1202
psi) and a maximum
1400 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 k 2 = 145.8115
stress under
1600 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 k 3 = 0.2552
Factored loads of 207
MPa (29,700 psi). 1800 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 k 4 = -0.1660
2000 18.6 18.6 18.6 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
1.22
5. Load values are 2200 15.8 15.8 15.8 17.8 17.8 17.8 20.0 20.0 20.0 20.0
based on Normal 2400 13.7 13.7 15.4 15.4 18.0 18.0
Weight Concrete 2600 12.0 12.0
(density of 2300 2800
kg/m3) (145 pcf) with 1800 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
a minimum 2000 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
compressive strength 18.9 20.0 20.0 20.0
2200 18.9 18.9 20.0 20.0 20.0 20.0 20.0 20.0
of 20.7 MPa (3,000 1.52 2400 16.4 16.4 16.4 18.5 18.5 18.5 20.0 20.0 20.0 20.0 20.0
psi) and a Modular
2600 14.5 14.5 14.5 16.3 16.3 19.1 19.1 20.0 20.0
Ratio n=9
2800 12.9 12.9 14.5 14.5
3000 11.4

Continued on back
In accordance with ongoing efforts to improve our products and their performance, Vicwest
reserves the right to change without notice the specifications contained herein.
The contents herein are for general information and illustrative purposes only and are not intended to
serve as any type of advice. Every effort is made to ensure the accuracy of the information included in
this brochure and it is believed that the information contained herein is accurate and reliable as of the
date of publication. Vicwest, however, does not warrant or represent the accuracy or reliability of any
information included in this brochure. Any reliance on any information without consultation with Vicwest VW00147EN10/10
or a duly authorized representative shall be at the user's own risk. ©2010, Vicwest – All rights reserved
HI-BOND
COMPOSITE FLOOR

HB938
Z275 GALVANIZED

LIMIT STATES
DESIGN
IMPERIAL
PHYSICAL DEPTH FROM MAXIMUM FACTORED
SECTION MODULUS Moment of Inertia Note
NEUTRAL REACTIONS
PROPERTIES NOMINAL MASS WITH
MIDSPAN SUPPORT MIDSPAN FULL
AXIS TO
Continued from
STEEL PROFILE CORE AREA OF ZF75 BOTTOM OF EXTERIOR INTERIOR
STEEL GALVANIZED Sm Ss Im If DECK Y b front
THICKNESS (pounds) (pounds)
(inches) (inches2) (lb/ft2) (inches3) (inches3) (inches4) (inches4) (inches)

(PER FOOT WIDTH) .030 0.471 1.655 0.1784 0.1815 0.1566 0.1672 0.872 747 1076 6. No additional

In accordance reinforcing steel is


.036 0.566 1.977 0.2176 0.2290 0.1954 0.2006 0.876 1048 1528
required for the slab
with CSA
.048 0.753 2.628 0.2952 0.3015 0.2666 0.2666 0.884 1768 2631 thicknesses shown
Specification on this table. For
.060 0.941 3.268 0.3720 0.3731 0.3327 0.3327 0.892 2666 4022
S136-07 temperature
SLAB THICKNESS 4.00 4.50 5.00 5.50 reinforcing (crack-
PHYSICAL
h(inches) control) steel, see
PROPERTIES Slab Weight, W1(lb/ft2) 39.7 45.7 51.6 57.6 the VICWEST Hi-
COMPOSITE SLAB Concrete Volume, (cu yd/100 ft2) 0.954 1.109 1.263 1.417 Bond Composite
Base Steel Nominal Floor Designer's
(PER FOOT WIDTH)
Thickness IC d IC d IC d IC d Manual.
Composite
(inches)
Moment of
.030 4.0604 3.128 5.7677 3.628 7.8957 4.128 10.4878 4.628 7. Hi-Bond composite
Inertia,
load capacities are
4
I C (inches ) .036 4.3444 3.124 6.1623 3.624 8.4227 4.124 11.1693 4.624 dependant on the
Effective Depth, .048 4.8510 3.116 6.8697 3.616 9.3720 4.116 12.4026 4.616 material finish of the
d (inches) steel. VICWEST
.060 5.3023 3.108 7.5039 3.608 10.2285 4.108 13.5219 4.608 publishes load tables
for ZF75 Galvanneal
Base Steel
LOAD Nominal 1 2 3 1 2 3 1 2 3 1 2 3 steel and Z275
TABLE Thickness Span Span Span Span Span Span Span Span Span Span Span Span Span Galvanized steel. For
(inches) (inches) other finishes contact
your local VICWEST
Maximum 4'-6" 400 400 400 400 400 400 400 400 400 400 400 400
office.
Specified 5'-0" 400 400 400 400 400 400 400 400 400 400
.030
Uniformly 5'-6" 397 397 400 400 400 400 400
6'-0" 335 335 8. Loads for the deck
Distributed Load
2 5'-0" 400 400 400 400 400 400 400 400 400 400 400 400 acting as a Form
in lb/ft (psf) include Slab Weight,
5'-6" 400 400 400 400 400 400 400 400 400 400 400
6'-0" 376 376 376 400 400 400 400 400 400 W 1 and a
.036
6'-6" 324 324 376 376 400 construction load of
7'-0" 283 283 1.0 kN/m2 (21 psf)
7'-6" Uniformly Distrubuted
5'-6" 400 400 400 400 400 400 400 400 400 400 400 400 Live Load
400 400 400 400 OR
6'-0" 400 400 400 400 400 400 400 400
2.0 kN/m (137 lb/ft)
6'-6" 398 398 398 400 400 400 400 400 400 400 400 400
Transverse Live
7'-0" 351 351 351 400 400 400 400 400 400 400
.048 Load.
7'-6" 312 312 362 362 400 400 400 400
8'-0" 280 280 325 325
8'-6" 253 253 9. Load Table values
9'-0" allow for slab self
7'-0" 400 400 400 400 400 400 400 400 400 400 400 400 weight.
7'-6" 374 374 374 400 400 400 400 400 400 400 400 400
8'-0" 338 338 338 392 392 392 400 400 400 400
.060 8'-6" 307 307 307 356 356 400 400 400
9'-0" 281 281 326 326 371
9'-6" 258 258
10'-0"

In accordance with ongoing efforts to improve our products and their performance, Vicwest
reserves the right to change without notice the specifications contained herein.
The contents herein are for general information and illustrative purposes only and are not intended to
serve as any type of advice. Every effort is made to ensure the accuracy of the information included in
this brochure and it is believed that the information contained herein is accurate and reliable as of the
date of publication. Vicwest, however, does not warrant or represent the accuracy or reliability of any
information included in this brochure. Any reliance on any information without consultation with Vicwest VW00147EN10/10
or a duly authorized representative shall be at the user's own risk. ©2010, Vicwest – All rights reserved