Professional Documents
Culture Documents
CHARGING SOLUTIONS
FOR ELECTRIC VEHICLES
OR PLUG-IN HYBRIDS
UNSHUTTERED
PLUG
PLUG suitable
for unshuttered
vehicle coupler
MODE 3
T2 PLUG
1
BUILDING ELECTRICAL
30 mA
Safety contact
20 A to 40 A RCBO 3.7 kW single-phase
(1)
3hrs
Pilot wire for off-peak
signal or clock 7.4 kW single-phase
Green’up Premium charging station
3.7 to 7.4 kW single-phase
(1) Average time for full charge according to manufacturer sources, variable depending on the model
1
Select your charging solution
for residential or
commercial buildings
2 IK 08 AND IK 10 GREEN’UP ACCESS SOCKET MODES 1 & 2
Charging time
GREEN’UP CHARGING SOLUTIONS
IP 55 - IK 08
14 A - 3.2 kW
single-phase
IP 55 - IK 10
14 A - 3.2 kW
single-phase
IK 08 socket
Optimum safety
Surface treatment of
metal contacts
to improve electrical
conductivity
DETECTION SYSTEM
PATENTED BY LEGRAND
Vehicles detect the secure Green’up
infrastructure and select the
maximum power that can be
supplied via the socket, resulting
in a shorter charging time.
IK 10 socket
(1) Average time for full charge according to manufacturer sources, variable depending on the model
2
GREEN’UP PREMIUM CHARGING STATION MODES 1 & 2 3
MODE 3
(1)
6hrs
IP 44 - IK 08
3.7/4.6 kW single-phase
IP 44 - IK 08
7.4 kW single-phase
Integrated
off-peak control
Automatically charges
during off-peak hours,
with override button for operation
outside the low-tariff period
“
SOLUTION THAT IS INEXPENSIVE,
ADAPTABLE AND SAFE
With the IK 08 and IK 10 Green’up
Access socket, Legrand makes it easy WHEN I'M AT HOME,
to charge vehicles at home and in I CAN CHARGE MY
public car parks. ELECTRIC VEHICLE
Inexpensive, simple to install, safe,
OVERNIGHT IN
they can also be used for all
conventional purposes, and are COMPLETE SAFETY
specially prewired so they can easily
be replaced with a mode 3 charging
station.
3
4 READY TO INSTALL GREEN’UP ACCESS MODES 1 & 2
Charging time
GREEN’UP CHARGING SOLUTIONS
IP 66 - IK 08
14 A - 3.2 kW
single-phase
30 mA Hanging bracket
20 A RCBO - C curve - Detects For the charging
faults with AC and DC components cable control box
(1) Average time for full charge according to manufacturer sources, variable depending on the model
4
Green’up sockets and charging stations
TM
TYPE 2
for electric vehicles and plug-in hybrids
SINGLE-PHASE - 230 V
0 904 70(1)
3.2 Plastic 55 08 1 - 6(2) 8(2) -
0 904 72
Metal
3.2 55 10 1 0 778 57 - 6(2) 8(2) -
with key
3.7/4.6 0 590 20 4 6 8
Mode 3 Plastic 44 08 1 -
7.4 0 590 29 2.5 3.5 4.5
Modes 2
and 3
5
Green'up Access ready to install kit
TM
Green'up Access sockets
TM
0 904 72 0 778 56
6
Green'up Access sockets TM
Single-phase Green’up Premium TM
charging stations
Charging stations
n Installation principle for an individual mode 2 socket compliant with ZE
Ready(1) specifications
In electrical panel, dedicated RCBO Cat.No 4 110 95
20 A, C curve - 30 mA - Type HPI With power adjustment
16 A
10 mA function
Dedicated line 3 x 2.5 mm2 minimum
L N Integrated
residual current
(3 x 6 mm2 maximum)
protection
Green'Up Access
2P+E socket
7
Single-phase Green’up Premium TM
charging stations
ET
15V
16A
10mA
min. 3 x 2.5 mm2 / 4 mm2 / 6 mm2 /10 mm2
110/4
6kA
electronic circuits of the charging T2S line
station(*) min. 3 x 2.5 mm2 4 115 91 4 115 91 4 115 91 4 115 91 4 115 91 4 115 91 4 115 91 4 115 91
protection by RCCB +
T2S + + + + + + + +
MCB(1)(2)
4 077 43 4 077 44 4 077 45 4 077 46 4 077 43 4 077 44 4 077 45 4 077 46
Min. cross section of the
Same line
2P+E cable supplying Green'Up
Safety signal 2 x 1.5 mm2 Not concerned Not concerned as T2S 2.5 2.5 2.5
Access 2P+E socket
socket
Optional (mm2)
For remote control (with programmable time switches), Rated current & tripping
3 x 1.5 mm2, 230 V Same
curve of the RCBO
protection 20 A 20 A 20 A
* : Except Cat.No 0 590 20 and charging stations set to 16 A / 3.7 kW protecting the line Not concerned Not concerned
as T2S C curve C curve C curve
supplying Green'Up
line
Access 2P+E socket
Same
RCBO for the line
protection
supplying the Green'Up Not concerned Not concerned 4 077 43 4 077 43 4 077 43
as T2S
Access 2P+E socket
line
Current shunt trip / safety
4 062 76 4 062 76 4 062 76 4 062 76 4 062 76 4 062 76
signal
T2S line:
Charging station rated current (A) 16 20 25 32
min. 3 x 2.5 mm2 / 4 mm2 / 6 mm2 /10 mm2
Integrated into Integrated into Integrated into Integrated into
Residual current protection: 30 mA Hpi
the station the station the station the station
L N T2S Rated current & tripping curve of the 20 A 25 A 32 A 40 A
MCB protecting the T2S line C curve C curve C curve C curve
2P+E Minimum cross section of the T2S
2.5 4 6 10
cable (mm2)
Optional
4 077 43 4 077 44 4 077 45 4 077 46
For control signal: 230V A by MCB (1)
(6000/10kA) (6000/10kA) (6000/10kA) (6000/10kA)
3 x 1.5 mm2, 230 V T2S line protection
4 110 95 4 110 96 4 110 97 4 110 98
by RCBO
16A
8
Green'up Access sockets
TM
Single-phase Green'Up Premium TM
charging stations
365
98 70
Cat.No 0 904 78
300 mini
115 6 190
Ø6
200 Ø 13
92.5
Ø6
147.5
600 mini
900 mini
180 28
Cat.No 0 778 56
110 26 21
12 mini
97
70
Ø 13
Cat.No 0 778 57 206
110 26 48 230
1200
110
9
FOLLOW US
ALSO ON
legrand.com
youtube.com/user/legrand
facebook.com/Legrand
twitter.com/Legrand
pinterest.com/legrandgroup
instagram.com/legrandnews
EXB16013 ©Legrand - April 2016
Head office
and International Department
87045 Limoges Cedex - France
Tel. : + 33 (0) 5 55 06 87 87
Fax: + 33 (0) 5 55 06 74 55