MASK FASTENERS PVT LTD

MAGNETIC PARTICAL EXAMINATION REPORT

TEST REPORT NO. : MPI/12/2019-20 DATE : 07/05/2019

: M/s. JVS Flow Control Pvt Ltd Procedure MFPL/


NAME OF CUSTOMER 723-724-725, G.I.D.C. Makarpura,
vadodara - 390010 Surface
Praparation Satisfactory

þK Electronic make
Equipment
¨Magnaflux Make
Details of Job : Stud 1.1/4"x8unc x (l)140mm. ¨MT - 1500
Model þMT - 6000
Stage of Inspection : As Final condition ¨Y7 - YOKE
Current Apply þAC ¨DC ¨HWDC
Method : þWet ¨ Dry þContinuous þASTM Field Indicator
¨Visible þFlurescent ¨Residual Sensitivity þA Meter
Checked By ¨Lifting Capacity

Magnetization : ¨circular þlongitudinal ¨yoke Ref Standard


technique ASME SEC.V,SE-709

To Examination Surface & Sub-Surface


For defect
Tested At : "Mask Fasteners Pvt Ltd"

Result :

Sr. No. Desription of Particular Material Discontinuity


Stud 1.1/4 x 8 unc x (L) ASTM A193 GR
1 No Signifiacant indication observed
(Qty:16 nos ) B7M
Remark: Acceptable
Sketch:
-NA-

Tested By Client Inspection


Sachin Rokade Authority

Level - I Page no 01
C 129/1 Industrial Area Supa,Tal Parner, Dist Ahmednagar-414301 Maharashtra, India