You are on page 1of 8

CADANGAN PEMBANGUNAN RUMAH KOS RENDAH YANG TERDIRI DARI :

FASA 1 : 6 BLOK 17 TINGKAT (1152 UNIT)


FASA 2 : 2 BLOK 16 TINGKAT ( 360 UNIT )
TERMASUK 8 UNIT KEDAI (TINGKAT BAWAH BERSERTA KEMUDAHAN
AWAM DI ATAS LOT 14228, DI JALAN PJS 2C/C, KAMPUNG MEDAN PJS 2,
PETALING JAYA, SELANGOR DARUL EHSAN
UNTUK TETUAN SYARIKAT PERUMAHAN NEGARA BERHAD

Hiley's Formula for Set Calculation of R.C. Driven Pile

Type of Pile : 300 x 300 mm R.C. Square Pile

Working Load of Pile : 45 tons

Provisional Pile Penetration Length : 30 meters

Driving Hammer Weight, W : 2.5 tons

Weight of Pile, P1 : 2.88 tons

Weight of Driving Cap, P2 : 0.41 tons

Total Weight, P = P1 + P2 : 3.29 tons

Hammer Drop Height, H : 600 mm

Coefficient of Resistance, N : 0.45

Temp. Compression, C : 12.5 mm (assumed)

W + (P . N2)
Efficiency factor, f =
W+P

= 0.5468

W.H.F
Ultimate Resistance, R =
S + c/2

Using factor of safety = 2 times working load of pile

R = 90 tons

Set per blow, s = 2.8641 mm

Set per 10 blows = 29 mm


0.2 0.2
MULTI SETIA DEVELOPMENT SDN. BHD.

Hiley's Formula for Set Calculation of R.C. Driven Pile

Type of Pile : 300 x 300 mm R.C. Square Pile

Working Load of Pile : 35 tons

Provisional Pile Penetration Length : 36 meters

Driving Hammer Weight, W : 2.5 tons

Efficiency of Hammer , Wf : 0.75

Weight of Pile, P1 : 2.646 tons

Weight of Driving Cap, P2 : 0.41 tons

Total Weight, P = P1 + P2 : 3.056 tons

Hammer Drop Height, H : 600 mm

Coefficient of Resistance, N : 0.45

Temp. Compression, C : 12.5 mm (assumed)

W + (P . N2)
Efficiency factor, f =
W+P

= 0.5613

Wf.W . H . F
Ultimate Resistance, R =
S + c/2

Using factor of safety = 2 times working load of pile

R = 70 tons

Set per blow, s = 2.7716 mm


Set per 10 blows = 28 mm
0.175 0.175
CADANGAN PEMBANGUNAN RUMAH KOS RENDAH YANG TERDIRI DARI :
FASA 1 : 6 BLOK 17 TINGKAT (1152 UNIT)
FASA 2 : 2 BLOK 16 TINGKAT ( 360 UNIT )
TERMASUK 8 UNIT KEDAI (TINGKAT BAWAH BERSERTA KEMUDAHAN
AWAM DI ATAS LOT 14228, DI JALAN PJS 2C/C, KAMPUNG MEDAN PJS 2,
PETALING JAYA, SELANGOR DARUL EHSAN
UNTUK TETUAN SYARIKAT PERUMAHAN NEGARA BERHAD

Hiley's Formula for Set Calculation of R.C. Driven Pile

Type of Pile : 300 x 300 mm Round Pile


Throat
Working Load of Pile : 160 tons

Provisional Pile Penetration Length : 27 meters 0.301

Driving Hammer Weight, W : 7 tons

Efficiency of Hammer , Wf : 0.75 tons

Weight of Pile, P1 : 8.127 tons

Weight of Driving Cap, P2 : 0.41 tons

Total Weight, P = P1 + P2 : 8.537 tons

Hammer Drop Height, H : 920 mm

Coefficient of Resistance, N : 0.45

Temp. Compression, C : 12 mm (assumed)

W + (P . N2)
Efficiency factor, f =
W+P

= 0.5618

Wf.W . H . F
Ultimate Resistance, R =
S + c/2

Using factor of safety = 2 times working load of pile


R = 320 tons

Set per blow, s = 2.4797 mm

Set per 10 blows = 25 mm


0.5 0.5
0.325 0.325

8.127

You might also like