You are on page 1of 20

DESIGN OF ROLLED DOUBLY SYMETRIC I-BEAM AS PER AISC-LRFD (14th Edition)

Beam Section W12x22


d (inch) 12.300 d (mm) 312.42
bf (inch) 4.030 bf (mm) 102.36
tf (inch) 0.425 tf (mm) 10.80
tw (inch) 0.260 tw (mm) 6.60
Ag (in2) 6.480 Ag (mm2) 4180.64

Material Properties
E (Ksi) 29000 E (Mpa) 199947.98
Fy (Ksi) 50 Fy (Mpa) 344.74
beam o.w.(ib/ft) 22.050 beam o.w.(KN/m) 0.33

Applied forces
Mxu (Kip.Ft) 16
Myu (Kip.Ft) 0
Qu (Kip) 4 converter
m
SPAN 5.2
Lb (ft) 1.3
KN
Cb 17.2
Mmax. (Kip.Ft) 16 max. moment
Ma (Kip.Ft) 3.88 M @ 0.25L KN.m
Mb (Kip.Ft) 7.83 M @0.5L 16.1
Mc (Kip.Ft) 11.87 M @0.75L
Cb 1.69 Calculated value Mpa
Cb 1 Designed value 216

CHECK OF MOMENT
ΦMpx(Kip.Ft) 109.88 X-plastic moment
ΦMpy (Kip.Ft) 13.725 Y-plastic moment
Lp (ft) 3.00 Lm (ft) 3.00 Lr (ft) 9.17
ΦMn-LTB(Kip.Ft) 109.88 lateral torsional buckling flexural strength
λp 9.15
λr 24.08
λ=bf/2tf 4.74 compact flange
ΦMn-FLB (Kip.Ft) 0 flange local buckling flexural strength
ΦMnx (Kip.Ft) 109.88
ΦMny (Kip.Ft) 13.725
Mu/ΦMn 0.146 SAFE
CHECK OF SHEAR
ΦVn (Kip) 95.94 Vu/ΦVn 0.042 SAFE
METRIC I-BEAM AS PER AISC-LRFD (14th Edition)

converter
ft
17.06

KiP
3.87

KiP.ft
11.87

Ksi
31.33
DESIGN OF BUILT-UP DOUBLY SYMETRIC I-GIRDER AS PER AISC-LRFD (14th Edition)
Beam Section
h (inch) 45 d (mm) 1143.00
bf (inch) 24 bf (mm) 609.60
tf (inch) 1 tf (mm) 25.40
tw (inch) 0.3125 tw (mm) 7.94
Ag (in2) 38.063 Ag (mm2) 24556.40

Material Properties
E (Ksi) 29000 E (Mpa) 199947.98
Fy (Ksi) 36 Fy (Mpa) 248.21
beam o.w.(ib/ft) 129.518 beam o.w.(KN/m) 1.93

Applied forces
Mxu (Kip.Ft) 500
Myu (Kip.Ft) 500
Qu (Kip) 4 converter
m
SPAN 5.2
Lb (ft) 20
KN
Cb 17.2
Mmax. (Kip.Ft) 16 max. moment
Ma (Kip.Ft) 3.88 M @ 0.25L KN.m
Mb (Kip.Ft) 7.83 M @0.5L 16.1
Mc (Kip.Ft) 11.87 M @0.75L
Cb 1.69 Calculated value Mpa
Cb 1 Designed value 216

CHECK OF MOMENT
ΦMpx(Kip.Ft) 3407.95 X-plastic moment
ΦMpy (Kip.Ft) 780.566 Y-plastic moment
Lp (ft) 17.42 Lr (ft) 63.64
ΦMn-LTB(Kip.Ft) 3203.444 lateral torsional buckling flexural strength
λp (flange) 10.79
λr (flange) 15.95
λf=bf/2tf 12.00 non-compact
ΦMn-FLB (Kip.Ft) 3019.1488 flange local buckling flexural strength
λp (web) 106.72
λr (web) 161.78
λw=h/tw 144.00 non-compact
ΦMn-CFY (Kip.Ft) 3260.7038 compersion flange yielding flexural strength
ΦMnx (Kip.Ft) 3019.1488
ΦMny (Kip.Ft) 780.56631
Mu/ΦMn 0.806 SAFE
CHECK OF SHEAR
a (in) 120 Kv 5.70
ΦVn (Kip) 101.62 Vu/ΦVn 0.039 SAFE
D (14th Edition)

converter
ft
17.06

KiP
3.87

KiP.ft
11.87

Ksi
31.33
DESIGN OF ROLLED DOUBLY SYMETRIC I-COLUMN AS PER AISC-LRFD (14th Edition)
Column Section W16x45
d (inch) 16.10 d (mm) 408.94
bf (inch) 7.04 bf (mm) 178.82
tf (inch) 0.57 tf (mm) 14.35
tw (inch) 0.35 tw (mm) 8.76
rx (in) 6.65 rx (mm) 168.91
ry (in) 1.57 ry (mm) 39.88
Ag (in2) 13.30 Ag (mm2) 8580.63
Ix (in4) 586.00 Ix (mm4) 243911615.40
Iy (in4) 32.80 Iy (mm4) 13652390.76

Material Properties
E (Ksi) 29000 E (Mpa) 199947.98
Fy (Ksi) 36 Fy (Mpa) 248.21

Applied forces
working axial force converter
X-direction Y-direction m
dead load Pdx (Kip) 46.54 Pdy (Kip) 46.54 5.2
live load PLx (Kip) 0 PLy (Kip) 0
wind load Pwx (Kip) 0 Pwy (Kip) 0 KN
seismic load Psx (Kip) 0 Psy (Kip) 0 17.2
working bending moment
X-direction Y-direction KN.m
dead load Mdx (K.ft) 168.58 Mdy (K.ft) 0 21.6
live load MLx (K.ft) 0 MLy (K.ft) 0
wind load Mwx (K.ft) 0 Mwy (K.ft) 0 Mpa
seismic load Msx (K.ft) 0 Msy (K.ft) 0 216
ultimate shear force
Y-direction
total load Qu (kip) 0

Unbraced length and height


Lbx (ft) 17.06 Kx 1
Lby (ft) 17.06 Ky 1.2
L (ft) 17.06 story height

second order analysis parameter (effective length method)


X-direction Y-direction
Mu1x (K.ft) 320 M1 < M2 Mu1y (K.ft) 950 M1 < M2
Mu2x (K.ft) 320 Mu2y (K.ft) 1492
Single curvature Cmx 1.00 Single curvature Cmy
B1x 1.02 B1y 1.20
building lateral system unbraced building lateral system unbraced
ΣPstory (Kip) 11 Rmx 1 ΣPstory (Kip) 11 Rmy
ΣHx (Kip) 33.4 ΔHx (in) 0.336 ΣHy (Kip) 33.4 ΔHy (in)
B2x 1.00 B2y 1.00
Final design forces & moments
X-direction Y-direction
Pntx (Kip) 65.16 Pltx (Kip) 0.00 Pnty (Kip) 65.16 Plty (Kip)
Mntx (K.ft) 239.91 Mltx (K.ft) 0.00 Mnty (K.ft) 0.00 Mlty (K.ft)
Prux (kip) 65.16 Mrux (K.ft) 239.91 Pruy (kip) 65.16 Mruy (K.ft)

Cb
Mmax. (Kip.Ft) 1 max. moment
Ma (Kip.Ft) 1 M @ 0.25L
Mb (Kip.Ft) 1 M @0.5L Cb 1.00 Calculated value
Mc (Kip.Ft) 1 M @0.75L Cb 1 Designed value

NORMAL STRENGTH
(KL/r)max. 156.47 ΦFcr (Ksi) 9.23 ΦPn (Kip) 122.82
Prux/ΦPn 0.53 SAFE Pruy/ΦPn 0.53 SAFE

MOMENT STRENGTH
ΦMpx(Kip.Ft) 222.21 X-plastic moment ΦMpy (Kip.Ft) 39.15 Y-plastic moment
Lp (ft) 6.54 Lm (ft) 6.54 Lr (ft) 20.55
ΦMn-LTB(Kip.Ft) 158.53 lateral torsional buckling flexural strength
λp 10.79 λr 28.38 λ=bf/2tf 6.23 compact flange
ΦMn-FLB (Kip.Ft) 0.00 flange local buckling flexural strength
ΦMnx (Kip.Ft) 158.53 ΦMny (Kip.Ft) 39.15
Mrux/ΦMn 1.51 UNSAFE Mruy/ΦMn 0.00 SAFE

Interaction forces check


X-direction 1.876 UNSAFE Y-direction 1.876

CHECK OF SHEAR
ΦVn (Kip) 119.977 Vu/ΦVn 0.000 SAFE
-COLUMN AS PER AISC-LRFD (14th Edition)

converter
ft
17.06

KiP
3.87

KiP.ft
15.93

Ksi
31.33
0.85

1
0.5712
0.00
0.00
0.00

Calculated value
Designed value

Y-plastic moment

compact flange

UNSAFE
DESIGN OF BUILT-UP DOUBLY SYMETRIC I-COLUMN AS PER AISC-LRFD (14th Edition)
column Section
h (inch) 45 d (mm) 1143.00
bf (inch) 24 bf (mm) 609.60
tf (inch) 1 tf (mm) 25.40
tw (inch) 0.3125 tw (mm) 7.94
rx (in) 27.010 rx (mm) 686.07
ry (in) 7.780 ry (mm) 197.62
Ag (in2) 38.063 Ag (mm2) 24556.40
Ix (in4) 27769.047 Ix (mm4) 11558349968.33
Iy (in4) 2304.114 Iy (mm4) 959044838.49

Material Properties
E (Ksi) 29000 E (Mpa) 199947.98
Fy (Ksi) 36 Fy (Mpa) 248.21

Applied forces
working axial force converter
X-direction Y-direction m
dead load Pdx (Kip) 46.54 Pdy (Kip) 46.54 5.2
live load PLx (Kip) 0 PLy (Kip) 0
wind load Pwx (Kip) 0 Pwy (Kip) 0 KN
seismic load Psx (Kip) 0 Psy (Kip) 0 17.2
working bending moment
X-direction Y-direction KN.m
dead load Mdx (K.ft) 168.58 Mdy (K.ft) 20 16.1
live load MLx (K.ft) 30 MLy (K.ft) 15
wind load Mwx (K.ft) 50 Mwy (K.ft) 10 Mpa
seismic load Msx (K.ft) 20 Msy (K.ft) 5 216
ultimate shear force
Y-direction
total load Qu (kip) 500

Unbraced length and height


Lbx (ft) 20 Kx 1
Lby (ft) 17.06 Ky 1.2
L (ft) 17.06 story height

second order analysis parameter (effective length method)


X-direction Y-direction
Mu1x (K.ft) 320 M1 < M2 Mu1y (K.ft) 950 M1 < M2
Mu2x (K.ft) 320 Mu2y (K.ft) 1492
Single curvature Cmx 1.00 Single curvature Cmy
B1x 1.00 B1y 1.00
building lateral system unbraced building lateral system unbraced
ΣPstory (Kip) 11 Rmx 1 ΣPstory (Kip) 11 Rmy
ΣHx (Kip) 33.4 ΔHx (in) 0.336 ΣHy (Kip) 33.4 ΔHy (in)
B2x 1.00 B2y 1.00
Final design forces & moments
X-direction Y-direction
Pntx (Kip) 65.16 Pltx (Kip) 0.00 Pnty (Kip) 65.16 Plty (Kip)
Mntx (K.ft) 250.30 Mltx (K.ft) 80.04 Mnty (K.ft) 48.00 Mlty (K.ft)
Prux (kip) 65.16 Mrux (K.ft) 330.34 Pruy (kip) 65.16 Mruy (K.ft)

Cb
Mmax. (Kip.Ft) 16 max. moment
Ma (Kip.Ft) 3.88 M @ 0.25L
Mb (Kip.Ft) 7.83 M @0.5L Cb 1.69 Calculated value
Mc (Kip.Ft) 11.87 M @0.75L Cb 1 Designed value

NORMAL STRENGTH
(KL/r)max. 31.57 ΦFcr (Ksi) 30.74 ΦPn (Kip) 1170.22
Prux/ΦPn 0.06 SAFE Pruy/ΦPn 0.06 SAFE

CHECK OF MOMENT
ΦMpx(Kip.Ft) 3407.95 X-plastic moment ΦMpy (Kip.Ft) 780.566 Y-plastic moment
Lp (ft) 17.42 Lr (ft) 63.64
ΦMn-LTB(Kip.Ft) 3203.444 lateral torsional buckling flexural strength
λp (flange) 10.79 λr (flange) 15.95 λf=bf/2tf 12.00 non-compact
ΦMn-FLB (Kip.Ft) 3019.148796 flange local buckling flexural strength
λp (web) 106.72 λr (web) 161.78 λw=h/tw 144.00 non-compact
ΦMn-CFY (Kip.Ft) 3260.703807 compersion flange yielding flexural strength
ΦMnx (Kip.Ft) 3019.148796 ΦMny (Kip.Ft) 780.566309
Mrux/ΦMn 0.109 SAFE Mruy/ΦMn 0.082 SAFE

Interaction forces check


X-direction 0.219 SAFE Y-direction 0.219

CHECK OF SHEAR
a (in) 120 Kv 5.70
ΦVn (Kip) 101.62 Vu/ΦVn 4.920 UNSAFE
METRIC I-COLUMN AS PER AISC-LRFD (14th Edition)

converter
ft
17.06

KiP
3.87

KiP.ft
11.87

Ksi
31.33
0.85

1
0.5712
0.00
16.01
64.01

Calculated value
Designed value

Y-plastic moment

non-compact

non-compact

SAFE

You might also like