You are on page 1of 4

SLAB DESIGN( Interior panel)Long

FLAT PLATE 1800


Slab Thickness 9 fc(Ult.) 4000.00
fy 60,000.00
d 8
Slab panel 20.00 18.00
Live Load 60.00 psf For column Strip
Dead Load 100.00 psf Assume a 0.44 Assume a
FF 0.00 psf Actual a 0.437777034818 Actual a
PW 0.00
160.00 psf Assume a 0.14 Assume a
Factored load 242.00 Actual a 0.140243676285 Actual a

Clear length along Long direction= 18.75

Moment Calculation
Mo 191425.8 Ib-ft
Mo 191.4258 Kip-ft
Mn 212.70 Kip-ft
b(Column Strip)
b(Middle Strip)

Column Strip M(-ve) M(+ve) As(-ve)


104.22 K-Ft 44.67 K-Ft 2.98 in2 /width(for Column)
Middle Strip
34.03 K-Ft 29.78 K-Ft 0.95 in2 /width(for Middle)

For column Strip As(min)=

For Middle Strip As(min)=


SQRT Fc' 63.24555 psi
psi 3604997
psi

For Middle Strip


0.19
0.184652

0.12
0.122559

10
10

As(+ve)
1.26 in2 /width (for Column)

0.83 in2 /width (for Middle)

1.94 SQ IN

1.94 SQ IN
SLAB DESIGN( Interior panel)Long
FLAT PLATE 1800
Slab Thickness 9 fc(Ult.) 4000.00
fy 60,000.00
d 8
Slab panel 20.00 18.00
Live Load 60.00 psf For column Strip
Dead Load 100.00 psf Assume a 0.32 Assume a
FF 0.00 psf Actual a 0.32101093958 Actual a
PW 0.00
160.00 psf Assume a 0.1 Assume a
Factored load 242.00 Actual a 0.103369560418 Actual a

Clear length along Long direction= 16.75

Moment Calculation
Mo 169740.3 Ib-ft
Mo 169.7403 Kip-ft
Mn 188.60 Kip-ft
b(Column Strip)
b(Middle Strip)

Column Strip M(-ve) M(+ve) As(-ve)


92.41 K-Ft 39.61 K-Ft 2.62 in2 /width(for Column)
Middle Strip
30.18 K-Ft 26.40 K-Ft 0.84 in2 /width(for Middle)

For column Strip As(min)=

For Middle Strip As(min)=


SQRT Fc' 63.24555 psi
psi 3604997
psi

For Middle Strip


0.13
0.135929

0.09
0.090392

12
12

As(+ve)
1.11 in2 /width (for Column)

0.74 in2 /width (for Middle)

2.33 SQ IN

2.33 SQ IN