You are on page 1of 3

Specification for

Adsorbent Bed Accumulator

Item No: V-05202

Project No: 14308P

Novomer, Inc.
Project BioKim
Adana, Turkey
Client Reference: NVM-12-2520-PR-SPC-V-2522-3

This document contains confidential and proprietary information belonging to


Novomer Inc. and/or Cambridge Chemical Technologies Inc. and, except in
accordance with an agreement under which it was supplied, shall not be copied,
reproduced, distributed, or furnished in whole or in part to others in any form without
prior written authorization of both Novomer Inc. and Cambridge Chemical
Technologies Inc. (Ref. Novomer/CCTI CDA effective 5/25/2016).

Project Manager_________________________ Date____________

0 12-May-17 Issued for Package B - Area 1 YBR DCS Customer__________________________________ Date____________

Issue Date Description By Appr'd Sheet 1 of 3 Spec No: 14308P-SP-V-05202


PRESSURE VESSEL DESIGN DATA
Client: Novomer, Inc. Project No: 14308P Item No: V-05202
Unit: 052 - Solvent Recovery II Location: Adana, Turkey
REV Service: Adsorbent Bed Accumulator Manufacturer:
Note: √ indicates selection made by DEC No. Req'd: One (1)
Vertical/Horizontal : Vertical
Shell Diameter: Shell Length (TL-TL): MATERIAL Corrosion Allowance, mm
ID (mm): 1000 2600 mm Shell CS 3.0
OD (mm): √ Head Thickness: mm Heads CS 3.0
Temperature Pressure Internals CS 3.0
Operating: 0-240 °C 2.5 barg Top Head 2:1 Elliptical
Design: 275 °C 9.5 barg Bottom Head 2:1 Elliptical
Code ASME Section VIII, Div. 1
Emergency Vacuum Design No Nozzle Mark No. Size, in Qty. Rating Type
Liquid Height: (mm) LOW Note 2 HIGH Note 2 Vapor/ Liquid Inlet A 6 1 150# RF WN
Specific Gravity 0.907 @ 0 °C Liquid Outlet B 1.5 1 150# RF WN
Insulation Personnel Protection
Stress Relief for Process Reasons No Vapor Out K 6 1 150# RF WN
Level L1-L4 Note 1 4 150# RF WN
Manway M 18 1 150# RF WN
Boot Diameter mm Deep mm Pressure P Note 1 1 150# RF WN
Baffle Height mm Location Relief Valve RV LATER 1 150# RF WN
Temperature T Note 1 1 150# RF WN
Vent V 1.5 1 150# RF WN

SUPPORTS (Note 4) MATERIAL


Skirt Height mm
Saddles No.
Lugs No.
Legs
Pad
Insulation

Gen. Spec. Ref.


Client Spec. No's
Information to be Furnished by Others
Construction
Stress Relief
REMARKS (special conditions, start-up, shutdown, regeneration, vibration, etc. that may affect the mechanical design):
Notes:

1) Instrument nozzle sizing by DEC.


2) Liquid levels per equipment sketch.
3) Vessel elevation to be minimum for piping.
4) Support type by DEC.

ISSUE SHEET

0 2 of 3
1 2 3 4 5 6 7 8

K
A
RV V P

MIN

L2 L4

850

A A
200 A

SECTION A-A

E
HHLL = 1450

2600 A
TL-TL HLL = 1250

F 12" STD
CS HALF PIPE

1000 ID

LLL = 450

M
MIN
LLLL = 250
H

L1 L3 T

ELEV:
NOTE 3

J ANTI-SWIRL BAFFLES

Client Information:
VORTEX BREAKER NOVOMER, INC.
PROJECT BIOKIM
ADANA, TURKEY

B Drawing Information:
K EQUIPMENT SKETCH
ADSORBENT BED ACCUMULATOR
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED.
V-05202

Scale:
NONE

L
cambridge Project Number:
CHEMICAL TECHNOLOGIES 14308P
Drawing-Sheet No.
This document contains confidential and proprietary information belonging to
Novomer Inc. and/or Cambridge Chemical Technologies Inc. and, except in
accordance with an agreement under which it was supplied, shall not be copied,
14308P-SP-V-05202
reproduced, distributed, or furnished in whole or in part to others in any form
Sheet Issue
0 0 12 MAY 17 VKn ISSUED FOR PACKAGE B - AREA 1 YBR DCS - without prior written authorization of both Novomer Inc. and Cambridge

ISS. REV. DATE ISS. BY DESCRIPTION ENG. P.M. CLIENT


Chemical Technologies Inc. (Ref. Novomer/CCTI CDA effective 5/25/2016).
3 OF 3 0