Date of Issue: March 31, 2006

Affected Publication: API Specification 5CT, Specification for Casing and Tubing,
Eighth Edition, July 2005

ERRATA

3 Normative references: add, “ISO 9513, Metallic materials — Calibration of


extensometers used in uniaxial testing” after ISO 9402

7.14.4 Test solution: b) for Test Method D: change “…pH in range 2.6 to 2.8…” to “…pH
in range 2.8 to 3.0…”

8.12.2 Casing with API threads: fifth bulleted item: “LTC” should be “LC” by definitions

10.4.7 Test method: second paragraph, second sentence, add, “ISO 9513 or” after “… in
accordance with the procedures of…”

10.4.9: revise title to Re-tests — All products (except couplings, coupling


stock, pup joints or accessory materials in Grades C90, T95 and Q125)

10.15.11 Coupling stock, pup joints and accessories: delete “g)” and move the
entire paragraph currently in g) to become the second paragraph of 10.15.11 following: “—
magnetic particle inspection in accordance with ISO 13665 or ASTM E709.”

Figure D.15 — Measuring end straightness, Key 1: correct length to “1,8 m (6 ft)” (this
was correct in the 7th edition).

Table C/E.68 and 81: row 5, column 2, Mass designation, change comment to: “(fill in Label
2 designation from Tables C/E.1, C/E.2 or C/E.3)”

Table E.26: row 7 26, column 12, change “5.156” to “6.156”

H.7.2 Grades C90 and T95, PSL-3 (7.10.1): change “…as specified in H.7.1…” to “…as
specified in 7.10.1…”

H.18.3 NDE of untested pipe ends—All groups, PSL-3 (10.15.12): change title
to, H.18.3 NDE of pipe ends—All groups, PSL-3 (10.15.12); change sentence to,
“The pipe ends shall either be treated in accordance with 10.15.12 a) or c), or inspected after end
finishing (and before coupling installation on threaded and coupled tubulars) using the wet
magnetic particle method, or a method agreed between purchaser and manufacturer.”

--````,`,,`,,,,``,,```,,`,,``-`-`,,`,,`,`,,`---