ANALISIS Y DISEÑO DE MURO DE CONTENCION

ZONA 1 ( SP ):
Jose Maria Arguedas
bo q= 1 tn/m3 PREDIMENSIONAMIENTO
0.6 s/c
bo = (0.2 - 0.3)H 0.2
2 2
ɣc= 2.3 tn/m ɣ = 2.1 tn/m b = (0.4 - 0.6)H 0.5
φ= 39.2 ° H = 3.0 mts
C= 0.1
bo = 0.6
Arena Pobremente b = 1.5
Gradada (SP)

ɣ = 1.8 tn/m2
Hp = 1 m φ= 39 °
C= 0.1

φ= 39 1.5
C= 0.1 b
a= 0.9
δ= 0 SP

Ka = 0.23
Kp = 4.43
DIAGRAMA DE PRESIONES

3 6
5
2

2.07 2.76

1 4

8.0 3.45 1.4 0.23

N° Fv Fh Brazo MFv MFh


1 3.98 0.33 1.3
2 2.07 0.60 1.2
3 2.76 1.20 3.3
4 3.45 0.75 2.6
5 2.13 1.00 2.13
6 0.68 1.50 1.02
Fsv = 8.5 = 2.7 CORRECTO
∑ 12.26 2.81 ∑ 8.47 3.15
3.15

10.14
a FsD = 10.14 = 3.6 CORRECTO
10.07 2.81
ANALISIS Y DISEÑO DE MURO DE CONTENCION
ZONA 1 ( SP ):
Villa Rosario
bo q= 1 tn/m3 PREDIMENSIONAMIENTO
0.8 s/c
bo = (0.2 - 0.3)H 0.2
2 2
ɣc= 2.3 tn/m ɣ = 2.1 tn/m b = (0.4 - 0.6)H 0.5
φ= 39.2 ° H = 4.0 mts
C= 0.1
bo = 0.8
Arena Pobremente b= 2
Gradada (SP)

ɣ = 1.8 tn/m2
Hp = 1 m φ= 39 °
C= 0.1

φ= 39 2
C= 0.1 b
a= 0.9
δ= 0 SP

Ka = 0.23
Kp = 4.43
DIAGRAMA DE PRESIONES

3 6
5
2

4.14 5.52

1 4

8.0 4.6 1.9 0.23

N° Fv Fh Brazo MFv MFh


1 3.98 0.33 1.3
2 4.14 0.80 3.3
3 5.52 1.60 8.8
Fsv = 4 18.1
4.60 = 2.6 1.00
CORRECTO 4.6
5 6.87 3.79 1.33 5.06
6 0.90 2.00 1.81
∑ 18.24 4.70 ∑ 18.07 6.87
Fsv = 18.1 = 2.6 CORRECTO
6.87

15.06 FsD = 15.06 = 3.2 CORRECTO


a
4.70
14.95
ANALISIS Y DISEÑO DE MURO DE CONTENCION
ZONA 1 ( SP ):
Sauces
bo q= 1 tn/m3 PREDIMENSIONAMIENTO
1 s/c
bo = (0.2 - 0.3)H 0.2
2 2
ɣc= 2.3 tn/m ɣ = 2.1 tn/m b = (0.4 - 0.6)H 0.6
φ= 39.5 ° H = 5.0 mts
C= 0.1
bo = 1
Arena Pobremente b= 3
Gradada (SP)

ɣ = 1.8 tn/m2
Hp = 1 m φ= 39.5 °
C= 0.1

φ= 39.5 3
C= 0.1 b
a= 0.9
δ= 0 SP

Ka = 0.22
Kp = 4.50
DIAGRAMA DE PRESIONES

3 6
5
2

9.2 9.2

1 4

8.1 6.9 2.3 0.22

N° Fv Fh Brazo MFv MFh


1 4.05 0.33 1.3
2 9.20 1.33 12.3
3 9.20 2.50 23.0
4 6.90 1.50 10.4
5 5.84 1.67 9.73
6 1.11 2.50 2.78
∑ 29.35 6.95 ∑ 46.97 12.51
Fsv = 47.0 = 3.8 CORRECTO
12.51

24.49
a
FsD = 24.49 = 3.5 CORRECTO
24.46 6.95