DELHI N T P C Limited DOOSAN POWER


(A Government of India Enterprise) CONTRACTOR SYSTEMS INDIA PRIVATE
PROJECT JAWAHARPUR THERMAL POWER C.H.P CLEARANCE/INTERIM INSPECTION REPORT LIMITED
. PROJECT(2 X 660 MW)
PACKAGE EPC PACKAGE MANUFACTURER-REVA INDUSTRIES LTD
CONTRACT CW-MK-9877 issue
NO
ISSUE DATE 22/AUG/19 CHP_NO-01075652 PLACE FARIDABAD

SL REF
REMARKS Contd..
NO DOCUMENTS contd
PORT FOR THE OFFERED EOT CRANES,FOUND IN LINE NDARD.
WITH APPROVED PAINTING SCHEDULE.REPORT
NO:RQA/PAINT/5095/92,93. AS PER QP CLAUSES A.2,A.3,A.5,A.6: REVIEWED THIRD PARTY CHECK TEST REPORTS FOR
BASED ON THE ABOVE,OFFERED CRANES ARE CLEARED WHEELS,AXLES, GEARS ,PINIONS, GEAR BOX CASING,SHAFT,SHEAVES,ROPE DRUM AGAINST
FOR DESPATCH. CHARACTERISTICS AS PER APPROVED QP, FOUND MEETING THE REQUIREMENT OF
G] APPLICABLE STANDARD AND DRG.
EOT CRANES ARE IDENTIFIED BY HARD PUNCH OF SL.NO
AND NTPC STAMP(NTPC 0868) ON BODY OF HOIST,MAIN CHECK TEST REPORTS ARE CORRELATED BY M/S REVA INDUSTRIES INTERNALLY ASSIGNED
GIRDER AND HOOK. GE NUMBER.
H)
SUPPLIER TO RETAIN SUMMARY SHEET REFERENCE NO: AS PER QP CLAUSE B.3, REVIEWED MANUFACTURER’S TC AND M/S REVA INDUSTRIES
RQA/SS/5095.92,93,94,95 AND ALL ITS BACK UP DOCUMENTS INTERNAL INSPECTION REPORTS FOR UT, DPT AND PROOF LOAD TEST FOR HOOK , FOUND
AND WITNESS REPORTS FOR FUTURE REFERENCE IF ANY. MEETING THE REQUIREMENT OF APPLICABLE STANDARD EXCEPT FOR ONE OBSERVATION
I) ENSURED CALIBRATION STATUS OF ALL THE WHICH IS MENTIONED IN REMARK SL.NO: F.
MEASURING AND TESTI
AS PER QP CLAUSE B.2, REVIEWED MANUFACTURER’S TC FOR STEEL CORD AGAINST
CHARACTERISTICS AS PER APPROVED QP, FOUND MEETING THE REQUIREMENT OF
APPLICABLE STANDARD AND DRG.

AS PER QP CLAUSE B.6, REVIEWED MANUFACTURER’S ROUTINE TC FOR MOTORS OF THE


OFFERED EOT CRANES, FOUND MEETING THE REQUIREMENT SPECIFIED IN DRG EXCEPT FOR
. ONE DEVIATION WHICH IS MENTIONED IN REAMRK SL.NO:F.

REVIEWED TC/IR FOR ALL OTHER QP CLAUSES OF BOUGHT OUT ITEMS(AS APPLICABLE),
FOUND MEETING REQUIREMENT OF APPROVED DRG/DATA SHEET/APPROVED SUB VENDORS
LIST.
1 22 3 4
page Inspection Dates:-8/21/2019--8/27/2019--9/4/2019--
FOR CONTRACTOR/SUBCONTRACTOR Disposal code details FOR AND ON BEHALF OF N T P C Limited
L ACCEPTED MDCC NOT APPLICABLE
DOOSAN POWER SYSTEMS INDIA PRIVATE LIMITED//REVA
INDUSTRIES LTD S PRABHU
Doc no-QS-01-QAI-P-13/F3-R1 MANAGER(IS)

http://210.212.126.88/inspection/chpprint.asp?chpno=1075652 9/4/2019