You are on page 1of 6

Starter motor failure

SUMITOMO (S.H.I) CONSTRUCTION MACHINERY CO.,LTD


Starter motor failure
reduction type starting moter

SUMITOMO (S.H.I) CONSTRUCTION MACHINERY CO.,LTD


Starter motor failure
Failure
Planetary gear broken Sun gear worn out

Starter motor have been improved twice in the past.

1 : The pinion shaft diameter is increased


2 : Starter front bracket thickness is increased for rigidity

New failure showing in above pictures occurs occasionally.

SUMITOMO (S.H.I) CONSTRUCTION MACHINERY CO.,LTD


Starter motor failure
Failure rate

Average hour meter:1342 STDEV:926

SUMITOMO (S.H.I) CONSTRUCTION MACHINERY CO.,LTD


Starter motor failure
Investigation report
End of cranking

Cranking
Fluctuating

Stop time

System lag time


After stop engine cranking when engine failed to start,
fluctuating rotation is produced before engine stops completely.
SUMITOMO (S.H.I) CONSTRUCTION MACHINERY CO.,LTD
Starter motor failure
Root cause
If engine is re-started while fluctuating rotation is produced,
planetary gear will be damaged by kickback impact.

Counter measure
Starter motor will be controlled by ECM detecting engine speed,
and will be engaged 3 seconds after engine stopped completely.

Current → New
Not compatible
New starter relay

Engine harness also will be changed


SUMITOMO (S.H.I) CONSTRUCTION MACHINERY CO.,LTD