Harness And Wire Electrical Schematic Symbols
Symbols
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The
circle indicates that the component has screw terminals and a wire can be disconnected from it.
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.).
No circle indicates that the wire cannot be disconnected from the component.
Ground (Wired): This indicates that the component is connected to a grounded wire. The
grounded wire is fastened to the machine.
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine.
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the
16M Motor Grader contacts of a normally open reed switch; it opens the contacts of a normally closed reed switch.
Sender: A component that is used with a temperature or pressure gauge. The sender
Electrical System Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it. The
electromagnet can open or close the switch part of the relay.
F F
LONG RANGE LEFT RADAR
REAR LEFT RADAR R-C1
365-1271 2305010
GND 1 C234-R5 BK-18
CAN H 2 K900-R26 YL-18
CAN L 3 K990-R34 GN-18
Vs 4 C569-R12 YL-18
5 C234-R11 BK-18
6
C234-R5 BK-18
C234-R10 BK-18 C234-R1 BK-14
LONG RANGE RIGHT RADAR C234-R11 BK-18
REAR RIGHT RADAR R-C2
365-1271 2305010 C569-R12 YL-18
GND 1 C234-R10 BK-18 C569-R18 YL-18 C569-R2 YL-14
CAN H 2 K900-R20 YL-18
CAN L 3 K990-R28 GN-18 K900-R19 YL-18
Vs 4 C569-R18 YL-18 K900-R20 YL-18 K900-R3 YL-18
MP IO-1 5
K900-R26 YL-18
6
K990-R27 GN-18
K990-R28 GN-18 K990-R4 GN-18
K990-R34 GN-18
CAN RESISTOR C234-CM6 BK-14
CAN 1 TERM RES B R-C3
174-3016 1330973
A K900-R19 YL-18
200-CM7 BK-14
E B
C
K990-R27 GN-18
CAB 200-CM4 BK-14 E
GROUND
20A
130-CM1 RD-12 200-CM7 BK-14 3 GROUND
4
C569-CM20 YL-14 5 +12V SWITCHED OUT
D D
RD-12
130-CM1 RD-12 130-CM2 RD-14 6
130-CM3 RD-14
200-CM4 BK-14
109-CM29
200-CM7 BK-14
308-FUSE2 YL-12
CM-C16
3045284 308-FUSE2 YL-12 308-CM8 YL-16
CM-C3
1 2 308-CM9 YL-16
1330973
FUSEBLOCK 308-FUSE1 YL-12
892-CM10 BR-16 K900-CM25 YL-18 A
CAN 1 TERM RES A
109-CM29 MUST BE CONNECTED TO THE UNSWITCHED SIDE (115 RD P-T4) 892-CM15 BR-16 892-CM14 BR-16 K990-CM27 GN-18 B
174-3016
CONNECT TO THE EXISTING FUSE PANEL P-C1 C
308-YL MUST BE CONNECTED TO THE SWITCHED SIDE (112-PU P-T1)
CONNECT TO THE EXISTING FUSE PANEL P-C3 893-CM11 GN-16 893-CM12 GN-16
893-CM13 GN-16
C569-CM20 YL-14
C 8 K900-CM17
K990-CM16
YL-18
GN-18
7
8
CAN 1 +
CAN 1 -
C
9
308-CM8 YL-16 10 KEYSWITCH
130-CM2 RD-14 11 BATTERY +
CM-C8 CM-C7 200-CM4 BK-14 12 BATTERY -
UNPLUG FROM P-C21 (SERVICE CONNECTOR)(9W-1951 9 PIN HD10) 3E3364 1552269
PINS D & E AND CONNECT TO CM-C8 892-P428 BR-16 1 892-CM10 BR-16 CM-C2
PIN D 893-P429 893-P429 GN-16 2 893-CM11 GN-16 1552253 USB
PIN E 892-P428 1
2
(Dimensions: 25 inches x 24 inches)
3
4
5
GROUND CIRCUIT
PART NUMBER DESCRIPTION WIRES THAT HAVE SYSTEM VOLTAGE WHEN THE KEY SWITCH IS OFF
283-0657 3 METER VIDEO CABLE WIRES THAT HAVE SYSTEM VOLTAGE WHEN THE KEY SWITCH IS ON
VOLTAGE CONVERTER OUTPUT CIRCUIT
GY GRAY
ATTACHMENT: CAT DETECT OBJECT DETECTION
H# CIRCUIT GROUPING DESIGNATION
7 6 5 4 3 2 1