Professional Documents
Culture Documents
Barrage and Weir0.1
Barrage and Weir0.1
1 DATA
Design Flood Q 200 m3/s
Average bed level of river 1941 m
Maximum water level 1946.3 m
Full Reservoir level 1944 m
Height of weir 3m
Crest level of weir 1944 m
Length of ungated weir portion 20 m
Width of crest of weir b 2m
Crest level of under sluice 1941 m
No of Bays in under sluice(Assumed) 2 Nos
Width of each bay in undersluice 3m
Height of undersluice D 2.5 m
Bottom level of breast wall 1943.5 m
Thickness of mid peir 1
thickness of divide wall(Assumed) 1
No of Divide walls in undersluice 1 Nos
Width of abutment 0.75 m
Free board 1.5 m
Total Width of diversion structure 29.50 m
Allowable afflux 1m
Particle size of sediment 0.3 mm
Lacy's Silt factor 0.96
Type of soil Single
u/s cutoff
Depth of scour hole 6.95 m 8.74
RL of bottom of scour hole 1940.00 m 1938.00
Provide upstream cutoff up to the elevation of 1940m.
D/s cutoff
downstream HFL 1940.13 1939.63
Depth of scour hole 9.26 m 11.65
RL of bottom of scour hole 1930.00 m 1927.00
Provide d/s stream cutoff up to the elevation of 1930m.
Use Concrete blocks of size 1.5mx1.5mx0.9m For 2 rows packed with Gravel through out the width
Provide concrete blocks of 1.5x1.5x0.9m For 3m over a well packed gravel layer of 0.6m
Provide 0.5m thick toe wall with bottom 1.3m width over a 0.15m thick pcc layer
a)For weir
; 2
λ 1.724683
GE 0.32
Floor thickness
a)For undersluice
1/; 0.05
ΦE 22 %
ΦD 18 %
ΦD1 82 %
Φc1 78 %
D 10.10 m
d 1.00 m
d1 1.00 m
b 19.50 m
Correction for Upstream cutoff
a)Correction due to Effect of cutoffwalls
C 7.79 %
b)Correction For depth
C 4%
c) Correction for slope
Φc1 Corrceted 89.79 %
Corrected depth of cutoff wall 1.90 m
m
m
m
m
m
avel through out the width