Professional Documents
Culture Documents
Audit Details
Lead Auditor: Paula Susín Brabo Date: January 9 - 2015
Company Details
Company Name: MEFASA Total No of Employees: 140 Part Time: 0
Temporary: 30 Contracted: 110 Others: 0
Address: Av de la Playa 2 Contact: Daniel Garcia
23417-San Juan De Nieva (Asturias) Spain
Phone: +34-985-567290
Fax: +34-985-566926
Email: mefasa@mefasa.com
Work Instructions: there are instructions related with manufacturing and inspection.
Other: records related with internal audits, Mgt review, objectives, legal requirements, licences and inspection plans.
Scope:
MANUFACTURE OF MACHINERY EQUIPMENTS METALLIC; METALLIC STRUCTURES; BOILERS; PRESSURE VESSELS AND
COMPOSITE FOR THE GENERAL INDUSTRY
DIIS/AUDIT/01/2013/REV 0 Page 1 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
DIIS/AUDIT/01/2013/REV 0 Page 2 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
DIIS/AUDIT/01/2013/REV 0 Page 3 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Check next
No. N/Cs
Checked
this visit
No. Obs
ISO 9001:2008 Requirement Specific Areas to Address Next Visit
visit
4.1 General Requirements
4.2 Documentation Requirements x Design & Development (7.3) is not
included in the scope of certification but it
isn’ exclude.
5.1 Management Commitment
5.2 Customer Focus
5.3 Quality Policy
5.4 Planning x Some Q objectives are not quantified
5.5 Responsibility, Authority and Comm.
5.6 Management Review x There is no analysis of results from
customer satisfaction questionnaires
6.1 Provision of Resources
6.2 Human Resources
6.3 Infrastructure
6.4 Work Environment
7.1 Planning of Product Realisation
7.2 Customer Related Processes
7.3 Design and Development
7.4 Purchasing x There is no clear criteria followed to
downgrade a Non Conformant supplier
7.5 Production and Service Provision
7.6 Control of Monitoring & Measuring
Equipment
8.1 Measurement, Analysis and Improvement
8.2 Monitoring and Measurement x Although KPI are raised control processes ,
their results are not followed and analyzed .
DIIS/AUDIT/01/2013/REV 0 Page 5 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Customer Complaints:
TOTALS 4 2
DIIS/AUDIT/01/2013/REV 0 Page 6 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Audit Summary
NC, AC, AP. Internal audits
PGCSM-04 NC Process control.
GNCP-1 Process to suppliers NC control.
NC nº 1260, 1273, 1148, 1160
Internal audits are done regularly and the non conformities detected are treated as per indicated in the NC procedure,
together with external audits NCs.
The treatment of the non conformities is not enough. They don’t analyse the root case in most of them, and the graduation
major, moderate, minor has not an objective criteria.
Also there should be a classification of the non conformities in order to analyse them and know where the system can fail
(machine, measurement, storage, etc)
Objectives, KPI:
Quality targets are established but they need to be measure and followed.
Some of the targets are not quantified and its following is just made when time is finished. They need to improve analysis
methodology and report every target they get.
KPI’s established for 2015 are an improvement respect last year. There is new KPI defined for production, but they have
to analyse the results, what to do if it is bad or why it is bad. There is a lack of data analysis in general.
2015 Management review is not available yet. Management review 2014 doesn’t present a good analysis of KPI’s or
quality objectives. It just mention if they are reached or not.
Purchasing. Suppliers
PGCSM-23, 1/10/12 Purchasing general conditions.
PGCSM-18 Purchasing manangement.
Acopio nº 2013011430, 2013011388, 2013002893, 2013012174.
Suppliers: Hierros Juan Manuel, Mecanizaciones industrials San Claudio.
Purchasing traceability. Very good traceability in all the process.
There are no established criteria for evaluating suppliers.
Calibration
Micro 32403039, Patrón cilíndrico 1893E-13, Manómetro NS49, nº 32404007, Pie de rey 32403056, Welding tool 216.
No comments.
Customer satisfaction
They send a test every year but results are not analized.
Conclusions:
The standard is correctly implemented in general. They should improve some points as the analysis of nonconformities or
objectives . It is found that they are working to improve the KPI and analysis of production processes .
DIIS/AUDIT/01/2013/REV 0 Page 7 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
N/c
Ref Clause
or Non-Compliances / Observations Raised
No. No.
Obs
8.2.3 NC Although KPI are raised, their results are not followed and
analyzed. Nor threshold values indicating when the result set
2
is considered acceptable.
5 7.3 Obs Design & Development (7.3) is not included in the scope of
certification even if the company has it among its activities
DIIS/AUDIT/01/2013/REV 0 Page 8 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Attendees:
MEFASA: Daniel Garcia (Quality Mgr), Francisco Alvarez (Responsible Planning)
(a) Thank the company for their hospitality and for their assistance and co-operation.
(b) Overall summary of assessment, non-compliances and observations found during the
audit.
(c) Explain procedure for submitting Corrective Action Plan and Objective Evidence if
Required
(d) Present recommendation for or against certification or its continuance
(e) Explain the continued surveillance audit cycle
(f) Invite questions from the company’s representatives including comments on this report
(g) Leave a photocopy/electronic copy of the DIIS Audit Report with the company.
DIIS/AUDIT/01/2013/REV 0 Page 9 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Notes:
Photo Evidence
DIIS/AUDIT/01/2013/REV 0 Page 10 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Audit Details
Lead Auditor: Paula Susín Date: 11 February 2015
Company Details
Company Name: Irmãos Valente Lda. (IRVA)
Address: Rua Comendador Arlindo Soares de Pinho Contact: Paulo Tavares / Ricardo Marques
1976 – Lordelo
Phone: + 351 256464222
3730-423 Vale de Cambra
Portugal Fax: + 351 256422003
Email: qualidade@irmaosvalente.pt
1. Objectives and Programme – “Objectives Measuring and monitoring Matrix, 2014” – 100%
achieved
2. Audits – IRVA.PR.002.01, 01/03/2013; Annual programme (28/01/2015); Last Internal audit Report
(30 and 31/01/2014); TÜV report (21/03/2014); auditors competence conformant
3. QMS Management Review – Last on 02/02/2015
4. Document control / Records – IRVA.SGQ.0313.003.01; IRVA.SGQ.0313.001.01;
IRVA.SGQ.0312.009.00
Work Instructions: NA
Other: NA
DIIS/AUDIT/01/2013/REV 0 Page 1 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
The contents of this report are confidential to the company, The signature of the company’s representative indicates their
as named above, and DIIS. As such, distribution to persons agreement and understanding of the noncompliance’s and
not under the employ of either party must be agreed by both observations found and that are the subject of this report.
parties prior to circulation. The non-compliances and
observations contained within this report are the result of
limited sampling and therefore it cannot be assumed that
others do not exist.
Signed: Signed:
(Auditor) (Company)
Name: Date:
DIIS/AUDIT/01/2013/REV 0 Page 2 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
DIIS/AUDIT/01/2013/REV 0 Page 3 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Audit Summary
DIIS/AUDIT/01/2013/REV 0 Page 5 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Audit Summary
1.0 Audit Scope
Quality Management System Audit / Pre-Qualification audit, required by China Harbour Engineering
Company (CHEC).
Auditees: Paulo Tavares, Nuno Pinto, Rui Pedro, Margarida Valente, Francisco Marques
Documentation:
Quality policy 6.4
Quality Manual rev.4, 3/3/2014
Objectives. KPI
2014 objectives/KPI record.
It should be improved the definition of objectives and actions to take to achieve them.
Customers satisfaction
Customers’ satisfaction report 21/1/15. A good satisfaction analysis based on the information obtained by
responsibles directly from customer contact is made. The results are positive .
Human resources
Ficha de funçao: técnico de manutençao, welder, quality manager.
2014 training plan.
Ficha de levantamento de necesidades de formación 2014.
It should be defined who is responsible for evaluating the effectiveness of the training
DIIS/AUDIT/01/2013/REV 0 Page 6 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Audit Summary
.
The quality system is young and is continually developing . Strong bases are established
and proposed improvements will mean a major progress in its system analysis.
DIIS/AUDIT/01/2013/REV 0 Page 7 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Audit Summary
N/c
Ref Clause
or Non-Compliances / Observations Raised
No. No.
Obs
1 7.6 Obs. Although it was evidenced for most equipment, there are a few absent
individual maintenance records (e.g. ESAB Nº 53).
2 6.2.2 Obs. It should be defined who is responsible for evaluating the effectiveness of the
training.
3 7.4.1 Obs. The suppliers are only evaluated / classified as capable or not capable.
Suppliers’ classification criteria should be defined more clearly and formally
implemented.
4 8.3 Obs It should be improved the classification of NC to facilitate analysis and set
new targets and indicators.
DIIS/AUDIT/01/2013/REV 0 Page 8 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
(a) Thank the company for their hospitality and for their assistance and co-operation.
(b) Overall summary of assessment, non-compliances and observations found during the audit.
(c) Explain procedure for submitting Corrective Action Plan and Objective Evidence if Required
(d) Present recommendation for or against certification or its continuance
DIIS/AUDIT/01/2013/REV 0 Page 9 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Photo Evidence
NA
DIIS/AUDIT/01/2013/REV 0 Page 10 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Audit Details
Lead Auditor: Paula Susín Date: February 10, 2015
Company Details
Company Name: COMECARAN SA Total No of Employees: 25 Part Time: 0
Temporary: 0 Contracted: 25 Others:0
Email: cmaranzazu@cmaranzazu.com
Procedures: procedures cover all Standard requirements and identified from PG-00 up to PG-18
Work Instructions:
Other: Documents list include some quality records like: inspection, training, customer satisfaction.
The contents of this report are confidential to the company, The signature of the company’s representative indicates their
as named above, and DIIS. As such, distribution to persons agreement and understanding of the noncompliance’s and
not under the employ of either party must be agreed by both observations found and that are the subject of this report.
parties prior to circulation. The non-compliances and
observations contained within this report are the result of
limited sampling and therefore it cannot be assumed that
others do not exist.
DIIS/AUDIT/01/2013/REV 0 Page 1 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Signed: Signed:
(Auditor) (Company)
Name: Paula Susín Name: Ruben Atutxa Date: Feb. 10, 2015
DIIS/AUDIT/01/2013/REV 0 Page 2 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
DIIS/AUDIT/01/2013/REV 0 Page 3 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Check next
No. N/Cs
Checked
Specific Areas to Address Next
No. Obs
this visit
ISO 9001:2008 Requirement
Visit
visit
4.1 General Requirements
4.2 Documentation Requirements
5.1 Management Commitment
5.2 Customer Focus
5.3 Quality Policy
5.4 Planning
5.5 Responsibility, Authority and Comm.
5.6 Management Review x Process performance analysis and
objectives should be improved
6.1 Provision of Resources
6.2 Human Resources
6.3 Infrastructure
6.4 Work Environment
7.1 Planning of Product Realisation
7.2 Customer Related Processes
7.3 Design and Development
7.4 Purchasing
7.5 Production and Service Provision
7.6 Control of Monitoring & Measuring
Equipment
8.1 Measurement, Analysis and Improvement
8.2 Monitoring and Measurement
8.3 Control of Nonconforming Products x Root cause analysis and classification
should be improved
8.4 Analysis of Data
8.5 Improvements
Customer Complaints:
TOTALS 2
DIIS/AUDIT/01/2013/REV 0 Page 5 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Audit Summary
General Comments or Concerns and details of any temporary sites:
Management review. KPI. Objectives. Quality policy April 2013. Internal audits. Treatment of NC. AC. AP.
Revised: 2013 Management review report and 2014 draft report
PG-06, april 2013. NC control
20015-NC-0045, order 4794
2014-NC-0030, order 5451
2014-NC-0284, 2014-NC0257
Action plan in order to decrease number of NC, 2014
2015 objectives are not established yet. 2014 objectives are closed and they evidence an improvement in NC
treatment.
Comecaran will implement new KPI for 2015 to improve monitoring and measurement of processes and
facilitate the approach of new targets.
They should pay attention to monitoring KPI and objectives and establishing corrective action if they are not
reached.
The treatment of NC can be improved. Root cause analysis should be deeper (not just “human mistake”). It’s
recommended a more detailed classification in order to facilitate the former analysis.
Internal audits are done regularly. Audit report February 15. No NC.
For order OF5456: Hoja de ruta, plan nºE113732C, pedido 27593, PPI
OF 5908 Registro de autocontrol/selfcontrol record, mainly used for dimensional control.
OF 5812 Hoja de ruta, plan E102756B, PPI.
Calibration: CC-02-039, AC-02-037, AC-02-056. Calibration plan, Calibration certificates.
Suppliers reevaluation.
DIIS/AUDIT/01/2013/REV 0 Page 6 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Audit Summary
The system is properly implemented . The nonconformities control process, establishing corrective actions and
traceability throughout the process are good . It should be improved the study of the non conformity root cause,
objectives program and KPI.
DIIS/AUDIT/01/2013/REV 0 Page 7 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
N/c
Ref Clause
or Non-Compliances / Observations Raised
No. No.
Obs
3 8.3 Obs
DIIS/AUDIT/01/2013/REV 0 Page 8 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Attendees:
Ruben Atutxa (General and Technical Mgr)
Jose A Berrojalbiz (Quality Mgr)
Paula Susín – Auditor
Michael Rannacher (Dash Inspector)
Oumar Seck – Operations Director (E. Beaudrey)
Julian Burgué– Project M
(a) Thank the company for their hospitality and for their assistance and co-operation.
(b) Overall summary of assessment, non-compliances and observations found during the audit.
(c) Explain procedure for submitting Corrective Action Plan and Objective Evidence if Required
(d) Present recommendation for or against certification or its continuance
(e) Explain the continued surveillance audit cycle
(f) Invite questions from the company’s representatives including comments on this report
(g) Leave a photocopy/electronic copy of the DIIS Audit Report with the company.
DIIS/AUDIT/01/2013/REV 0 Page 9 of 10
DASH INSPECTORATE INSPECTION DUBAI office Address:
SERVICES Dash inspectorate Inspection
services ,Post Box 45978
DUBAI- UAE 97143258469
AUDIT REPORT Mobile 971-508692438,971-
553548848
URL: www.dashinspectorate.com,
E-mail: dash@dashinspectorate.com,
Notes:
Photo Evidence
DIIS/AUDIT/01/2013/REV 0 Page 10 of 10