DATA
1) L 345 MM
2) b 345 MM
3) DISTANCE FOR LOAD APPLIED a 935 MM
4) LOAD 100 KN
5) fck 20 N/MM2
6) FY 500 N/MM2
7) ASSUME pt 0.5 > 0.40%
SOLUTION
b) LEVER ARM
z2/d2-(β/∞+β)z/d + (∞/∞+β)β2 0
∞=P/fck0.86bd 0.033261
β=a/d 1.230263
Solving Quadratic Eqn
z/d^2 - 0.973676 z/d + 0.039842 = 0
0.973676 + 0.888075 \ 2
z/d 0.930876
z 707.4654 mm
z=d-0.42x
x=2.38(d-z) x 125.0322 mm
x/d 0.164516 < 707.4654
Hence, No Compression reinf
DATA
1) L 345 MM
2) b 345 MM
3) DISTANCE FOR LOAD APPLIED a 335 MM
4) LOAD 100 KN
5) fck 20 N/MM2
6) FY 500 N/MM2
7) ASSUME pt 0.5 > 0.40%
SOLUTION
b) LEVER ARM
z2/d2-(β/∞+β)z/d + (∞/∞+β)β2 0
∞=P/fck0.86bd 0.0383
β=a/d 0.507576
Solving Quadratic Eqn
z/d^2 - 0.929837 z/d + 0.018076 = 0
0.929837 + 0.890108 \ 2
z/d 0.909973
z 600.582 mm
z=d-0.42x
x=2.38(d-z) x 141.4147 mm
x/d 0.214265 < 600.582
Hence, No Compression reinf