Point of ● Run CPU ● DI120~150

TCD - 021 DPRAM READ AREA ERROR of RUN CPU Application


detection ○ Speed CPU ● DI180~420
[Meaning] Run CPU communicates with Speed CPU to get Normal data area through
DPRAM. But in case that RUN CPU get random data from DPRAM [Action to take]
continuously 5 times. 1. Check the Joint condition of DOR-230 PCB CONNECTOR.
Check the connection cable contact condition
[Explanation]
among PCBs(MA, VE)

DPRAM READ 2. Check the SW1, SW2 position on DOR-230 PCB.

DPRAM read address and 3. If the TCD 21 occurs even though above action, replace
read size indicate the DOR-230,

read_data = Read the data of


indicated DPRAM address

no read_data == Read the data


of indicated DPRAM address
Yes

no Occur more than Succeed to read no

5 times continuously the indicated size?


Yes Yes

DPRAM READ
DPRAM READ OK
ERROR occur