You are on page 1of 7

Guestroom Control Unit myRoom Control Interfaces

369708i 1 05.21.18

myRoom Plus Guestroom Control Unit


Lutron myRoom Plus Guestroom Control Units 5 4 3 2 1 RJ45 RJ45
coordinate lighting, shades / draperies, and

Con/Act

Con/Act
L1

COM
L2

FD/Col

FD/Col
temperature control in a hotel guestroom. These can 2.0 A / L1, L2 250 mA
24 – 36 V-
be automated for guest comfort when the room PWR
becomes occupied and for energy savings when the
room is vacant.
The myRoom Plus Guestroom Control Unit(s) can myRoom
integrate with myRoom Vue and third-party systems GCU-HOSP
via the onboard Ethernet link with additional licenses. 24 – 36 V-
Examples include Property Management Systems IEC PELV / SELV / NECR Class 2
(PMS), Central Electronic Locking Systems (CELS) and www.lutron.com/qs

Building Management Systems (BMS).

lutron.com 1.844.LUTRON1

Model Numbers + 44.(0)20.7680.4481

PWR
GCU-HOSP 2 Link Control Unit ERR
L1
GCU-HOSP-1 1 Link Control Unit L1
L1
L1 TX /RX
L2
QS L1 QS L2 L2 TX /RX

COM
COM

MUX
MUX
MUX
MUX

V+
V+

D
D
1 2 3 4 5 1 2 3 4 5

GCU-HOSP shown

® S P E C I F I C AT I O N S U B M I T TA L Page 1
Job Name: Model Numbers:

Job Number:
Guestroom Control Unit myRoom Control Interfaces
369708i 2 05.21.18

Specifications
Regulatory Approvals Power Supply Wire Type
• RoHS Compliant • 18 AWG (0.75 mm2)
• Complies with UL508 Link Capacities
• Complies with CSA-C22.2 No. 14 • QS Wired Device Link: maximum 50 devices, 50
• Complies with IEC / EN 60669 zones, 50 occupancy sensors, and 100 switch legs
• NOM (ballasts, drivers, and interfaces).
• QS RF Link: maximum 50 devices and 100 zones.
Power
• 230 V~ Thermostat Control Link: maximum 32 room
• GCU-HOSP thermostats (LR-HVAC-230-S).
- Processor (P): 24 – 36 V- 250 mA
- Links (L1/L2): 24 – 36 V- 2 A per link • Power Panel Link - 16 addresses / 256 zones
• GCU-HOSP-1 Connections
- Processor (P): 24 – 36 V- 250 mA • GCU-HOSP
Typical Power Consumption - Two 5-pin, removable terminal blocks* for Link 1 and
• 5 W; 8 Power Draw Units (PDUs) Link 2 communications.
- One 5-pin, removable terminal block* for Power
Environment Input.
• Ambient Temperature Operating Range: • GCU-HOSP-1
32 °F to 104 °F (0 °C to 40 °C) - One 5-pin, removable terminal block* for Power
• Unit generates heat, maximum 24 BTU/hr Input / Link 1 communications.
• Relative humidity: 0% to 90% non-condensing Communication Links
• For indoor use only. • Each Lutron myRoom Plus Guestroom Control Unit
has up to three communication links:
Cooling Method – Link 1 and Link 2 (GCU-HOSP only): Lutron® QS
• Passive cooling wired device link, QS RF link, or thermostat control
link.
Internal Timeclock
– Ethernet:
• ±1 minute per year º GCU-HOSP — 2 Ethernet jacks for system
Power Failure Memory start-up and PMS / BMS / CELS integration. Up to
2 GCU-HOSP processors can be daisy chained
• System data stored in non-volatile memory. System for very large guestrooms.
programming retention for 10 years.
º GCU-HOSP-1 — 1 Ethernet jack for system
Miswire Protection start-up and PMS / BMS / CELS integration. Can
only be daisy chained via Ethernet to one
• All terminal block inputs are over-voltage and miswire
GCU-HOSP processor.
protected against wire reversals and shorts.
Communications Link Wire Type
• Two pairs: one pair 18 AWG (0.75 mm2), one pair
18 AWG to 22 AWG (0.75 mm2 to 0.34 mm2) twisted,
shielded: IEC PELV / NECR Class 2 cable
• Total wire length for each link must not exceed 500 ft
(152.4 m)
* Each terminal will accept up to two 18 AWG (0.75 mm2) wires.

® S P E C I F I C AT I O N S U B M I T TA L Page 2
Job Name: Model Numbers:

Job Number:
Guestroom Control Unit myRoom Control Interfaces
369708i 3 05.21.18

Specifications (continued)
System Capabilities
• Lutron QS Link allows control and programming of: • Lutron myRoom Plus Guestroom Control Unit can
– DIN rail power modules interface with the Hotel Service Optimization System
(HotSOS) via a wired Ethernet hotel network
– Palladiom and seeTouch QS keypads connection. Software license LMR-HOTSOS-PR is
– Palladiom QS thermostat required for a Newmarket HotSOS interface.
– Pico wireless controls (through QS sensor module) • Lutron myRoom Plus Guestroom Control Unit can
– Sivoia QS motorized shades / draperies interface with the hotel Building Management System
(BMS) via a wired Ethernet hotel network connection.
– Interfaces for door sensors, window sensors, room
Software license LMR-BAC-PR required for native
chimes, and privacy and service controls
BACnet interface.
• 230 V~ thermostat control link allows control of
• BACnet interface allows BMS to monitor and control
Lutron room thermostat (LR-HVAC-230-S).
room lighting, shades / draperies, temperature, room
• Keypad buttons can be programmed to toggle lights, occupancy and vacancy status, and identify system
select room scenes, or raise and lower lighting or faults.
shades / draperies.
• Lighting and HVAC load schedule data can be
• Conditional logic can be programmed to select programmed at start-up. This data is used to calculate
different actions based on inputs (e.g., time of day). room lighting and HVAC power usage, and is available
• Lutron myRoom Plus Guestroom Control Unit can to the hotel BMS for logging and reporting via the
interface with the hotel Property Management System native BACnet interface.
(PMS) via a wired Ethernet hotel network connection. • myRoom Vue can provide a powerful software
A software license is required. For example, interface to control, configure, monitor, analyze and
LMR-OPERA-PR is required to interface with MicrosR report on the myRoom Plus system. This requires
OperaT PMS. license LMR-MYRMVUE-PR.
• Lutron myRoom Plus Guestroom Control Unit can
interface with the hotel Central Electronic Lock System
(CELS) via a wired Ethernet hotel network connection.
A software license is required. For example,
LMR-SAFLOK-PR, LMR-SALTO-PR, or
LMR-VINGCARD-PR is required depending on which
CELS vendor is being used (KABAR Saflok, SALTOR,
or ASSA ABLOY VingCardR interface).

® S P E C I F I C AT I O N S U B M I T TA L Page 3
Job Name: Model Numbers:

Job Number:
Guestroom Control Unit myRoom Control Interfaces
369708i 4 05.21.18

Dimensions
Dimensions shown as: in (mm)

GCU-HOSP

Top View

Front View Side View


5 4 3 2 1 RJ45 RJ45
Con/Act

Con/Act
L1

COM
L2

FD/Col

FD/Col

2.05 A /4L1, L2
3 2502 mA1 RJ45 RJ45
Con/Act

Con/Act
L1

COM
L2

FD/Col

FD/Col

24 – 36 V-
PWR
2.0 A / L1, L2 250 mA
24 – 36 V-
PWR

myRoom
GCU-HOSP
myRoom
24 – 36 V-
GCU-HOSP
IEC PELV / SELV / NECR Class 2
24 – 36 V-
www.lutron.com/qs

IEC PELV / SELV / NECR Class 2


6.0 www.lutron.com/qs 5.26
(152) lutron.com 1.844.LUTRON1
+ 44.(0)20.7680.4481 (134)
lutron.com 1.844.LUTRON1 PWR
ERR
+ 44.(0)20.7680.4481
L1
L1 PWR
L1 ERR
L1 TX L1
/RX
L2 L1
QS L1 QS L2 L2L1TX /RX
L1 TX /RX
COM
COM

MUX
MUX
MUX
MUX

L2
V+
V+

D
D

1 L1
QS 2 3 4 5 QS 2 3 L24 TX5/RX
1 L2
COM
COM

MUX
MUX
MUX
MUX

V+
V+

D
D

1 2 3 4 5 1 2 3 4 5

4.27 1.06
(108) (27)

® S P E C I F I C AT I O N S U B M I T TA L Page 4
Job Name: Model Numbers:

Job Number:
Guestroom Control Unit myRoom Control Interfaces
369708i 5 05.21.18

Dimensions
Dimensions shown as: in (mm)

GCU-HOSP-1

Top View

Front View Side View

RJ45
Con/Act
FD/Col

myRoom
GCU-HOSP-1
24 – 36 V-
IEC PELV / SELV / NECR Class 2
5.63 www.lutron.com/qs 5.26
(143) (134)
lutron.com 1.844.LUTRON1
+ 44.(0)20.7680.4481

PWR
ERR
L1
L1
L1
L1 TX /RX

QS L1
COM

MUX
MUX
V+

1 2 3 4 5

4.27 1.06
(108) (27)

Lutron, Lutron, Palladiom, seeTouch, Pico, Sivoia, and Alena are trademarks of Lutron Electronics Co., Inc., registered in the U.S. and other countries.
myRoom is a trademark of Lutron Electronics Co., Inc.
SALTO is a trademark of Salto Systems, S.L.
VingCard is a trademark of ASSA ABLOY AB.
KABA and Saflok are trademarks of the Kaba Group.
Micros and Opera are trademarks of MICROS Systems, Inc.
HotSOS is a trademark of Amadeus IT Group and/or its affiliates.

® S P E C I F I C AT I O N S U B M I T TA L Page 5
Job Name: Model Numbers:

Job Number:
Guestroom Control Unit myRoom Control Interfaces
369708i 6 05.21.18

Mounting
The myRoom Plus Guestroom Control Unit can be installed in an LV16-120, LV16-230, HQ-LV21, L-LV21, or L-LV14
enclosure. It is typically powered using the QSPS-DH-1-75 or MQSPS-DH-1-30 power supply.

Power Supply 1,2
QSPS-DH-1-75 or
L(+) N(-)
L N
MQSPS-DH-1-30
120 - 240 V
Input / Entrada / Entrée
24 V
Output / Salida / Sortie
(up to 2)
Guestroom Control Unit 1,2
GCU-HOSP or
GCU-HOSP-1
22.5 - 25 V

+ −

OR
System Interfaces 1,2
5 4 3 2 1 RJ45 RJ45 RJ45
Con/Act

Con/Act

Con/Act
L1
L2

COM
P

FD/Col

FD/Col

FD/Col

2.0 A / L1, L2 250 mA


24 – 36 V-
PWR

myRoom myRoom
GCU-HOSP GCU-HOSP-1
24 – 36 V- 24 – 36 V-
IEC PELV / SELV / NECR Class 2
www.lutron.com/qs
IEC PELV / SELV / NECR Class 2
www.lutron.com/qs
Location for mounting QS
lutron.com 1.844.LUTRON1
+ 44.(0)20.7680.4481

PWR
ERR
lutron.com 1.844.LUTRON1
+ 44.(0)20.7680.4481

PWR
ERR
Wire Landing Board. 1
QS-WLB
L1 L1

QS L1
L1 L1
L1 L1
L1 TX /RX L1
1 TX /RX
/RX
L2

COM

MUX
MUX
L2 TX /RX

(up to 4)
QS L1 QS L2 QS L1

V+
COM
COM

COM
MUX
MUX
MUX
MUX

MUX
MUX
V+
V+

V+

D
D
D

1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
1 2 3 4 5

Common
From Power Supply
LV16 To Additional V+
QS Devices

(5) Ground
(4) Red “L2” Link 2 Power
(3) Red “L1” Link 1 Power
(2) Red “P” Processor Power
(1) Black “COM” Common
5 4 3 2 1 RJ45 RJ45
Con/Act

Con/Act
L1
L2

COM
P

FD/Col

FD/Col

2.0 A / L1, L2 250


50 mA
24 – 36 V-
PWR

myRoom
GCU-HOSP
24 – 36 V-
IEC PELV / SELV / NECR Class 2
5 4 3 2 1
L1

COM
L2

www.lutron.com/qs

lutron.com 1.844.LUTRON1
+ 44.(0)20.7680.4481
2.0 A / L1, L2 250 mA
PWR
ERR
L1
L1

Guestroom Control Unit 1


L1
IEC PELV / NEC Class 2 L1 TX /RX
L2
QS L1 QS L2 L2 TX /RX

GCU-HOSP or
COM
COM

MUX
MUX
MUX
MUX

L(+) N(-)
V+
V+

D
D

1 2 3 4 5 1 2 3 4 5

120 - 240 V 24 V

GCU-HOSP-1
Input / Entrada / Entrée Output / Salida / Sortie

Power Supply 1
QSPS-DH-1-75 or
22.5 - 25 V

MQSPS-DH-1-30 3

Location for mounting QS Wire Landing Board. 1


QS-WLB
L-LV14 (up to 2)
1
All components sold separately.
2
Maximum of 2 Control Units / Interfaces allowed per enclosure.
3
Requires mounting kit MQSPS-BRK.

® S P E C I F I C AT I O N S U B M I T TA L Page 6
Job Name: Model Numbers:

Job Number:
Guestroom Control Unit myRoom Control Interfaces
369708i 7 05.21.18

System Diagram Example

Palladiom QS keypad Palladiom QS keypad

To HVAC
controller

Palladiom QS Palladiom QS Alena


keypad thermostat QS wired
drapery track

QS Sensor
Module
Palladiom QS QS wired
keypad connection
Wireless
occupancy
sensor
PGM 5 4 3 2 1 RJ45 RJ45
CCO 5
CCO 4
CCO 3
CCO 2
CCO 1
Status

O
N
Con/Act

Con/Act
L1
L2

COM
P

FD/Col

FD/Col

8 7 6 5 4 3 2 1 0 2 7 5 5 7 6 1 32 3 1

2.0 A / L1, L2 250 mA


24 – 36 V-
PWR

QSE-IO
24 - 36 V- 100 mA
myRoom TM

SELV /PELV /NECR Class 2 GCU-HOSP


www.lutron.com/qs 24 – 36 V-
IEC PELV / SELV / NECR Class 2
www.lutron.com/qs

lutron.com + 1.800.523.9466
+ 1.610.282.3800
lutron.com 1.844.LUTRON1
+ 44.(0)20.7680.4481

PWR
V R R
ERR
0-36 V- 1A V L1
0-36 V~ ½A L1
L1
L1 TX /RX
CCO 1 NO

CCO 2 NO

CCO 3 NO

CCO 4 NO

CCO 5 NO
CCO 1 NC

CCO 2 NC

CCO 3 NC

CCO 4 NC

CCO 5 NC
1-2 COM

3-4 COM

5 COM

L2
QS

QS L1 QS L2 L2 TX /RX
COM
MUX

MUX

COM
COM

MUX
MUX
MUX
MUX
V+

CCI 1
CCI 2
CCI 3
CCI 4
CCI 5
COM

V+
V+

D
D

4 3 2 1 1 2 3 4 5 1 2 3 4 5

Load controllers Contact Guestroom Palladiom


(wired) closure control unit QS keypad
interface
Property Management System
To door contact (PMS)
Hotel
To door bell
Network Building Management System
To third-party (BMS)
corridor plate
To receptacle Central Electronic Locking System
controller (CELS)

Third-Party Integration

myRoom Vue Dashboards

® S P E C I F I C AT I O N S U B M I T TA L Page 7
Job Name: Model Numbers:

Job Number:

You might also like